Extron electronic 68-1021-01 user manual IP settings fields, Port Settings

Page 17

Communication and Control

IP settings fields

The IP settings fields provide a location for viewing and editing settings unique to the interface card. After editing any of the settings on this page, click the Submit button. Explanations for some of these fields follow.

Unit Name

This name field can be changed to any valid name, up to 12 alphanumeric characters.

The following characters are invalid in the unit name: {space} ~ @ = ‘ [ ] { } < > ’ “ ; : \ and ?.

DHCP

The Dynamic Host Configuration Protocol (DHCP) is an Internet protocol for automating the configuration of computers that use TCP/IP. DHCP can be used to automatically assign IP addresses, deliver TCP/IP stack configuration parameters such as the subnet mask and default router, and provide other configuration information such as the addresses for printer, time and news servers.

With DHCP “on,” you can also fill the Unit Name with your own host name (e.g., classroom1). For specific settings information, see your system administrator.

IP Address

The Address field contains the IP address of the IPL M PDP-ES interface card. This value is encoded in the flash memory of the interface card.

Valid IP addresses consist of four 1-, 2-, or 3-digit numeric subfields separated by dots (periods). Each field can be numbered from 000 through 255. Leading zeroes, up to 3 digits total per field, are optional. Values of 256 and above are invalid.

The default address is 192.168.254.254, but if this conflicts with other equipment at your installation, you can change the IP address to any valid value.

Edit this field and the following fields (Gateway IP Address and Subnet Mask) as follows:

1.

Click in the address field.

2.

Edit the address as needed.

3.

Press the Tab key on the keyboard or click in another field

 

to exit the IP Address field.

4.

Click the Submit button to make the address change take

 

affect.

Gateway IP address

The Gateway IP Address field identifies the address of the gateway to the mail server to be used if the interface card and the mail server are not on the same subnet.

To use Email Alert functions, the Gateway IP must be set. See Email Alerts page later in this chapter.

The gateway IP address has the same validity rules as the system IP address.

Subnet mask field

The Subnet Mask field is used to determine whether the

IPL M PDP-ES is on the same subnet as the mail server when you are subnetting.

Port Settings page

The Port Settings page allows you to view the ports settings and specify the baud rate.

To do so

1.Click Port Settings on the menu (on the left side of the window) and the Port Settings screen (figure 4-3) is displayed.

2.Use the drop-down menu to select the desired Baud rate.

3.Click the Submit button to enter the changes, or click the Cancel button to revert to the previous settings.

If using a control product (e.g., an MLC 206 or the Pioneer PlasmaTrol software) through the

IPL M PDP-ES card serial port, the card’s baud rate must match the requirements of the control product.

Figure 4-3 — web server Port Settings screen

4-4

IPL M PDP-ES • Communication and Control

IPL M PDP-ES • Communication and Control

4-5

Image 17
Contents IP Link Tools User’s ManualFCC Class a Notice PrecautionsExtron’s Warranty Attach the network LAN cable to the LAN port Quick Start Guide IPL M PDP-ESTable of Contents Introduction Table of Contents, cont’dIntroduction FeaturesAbout this Manual About the IPL M PDP-ES Interface CardIntroduction, cont’d Installation and OperationInstallation Overview Installation and OperationInstallation of the IPL M PDP-ES Interface Card Installing the Extron IPL M PDP-ES cardPanel Features and Cabling Installation and Operation, cont’dPower Ethernet/LAN communicationRS-232 communication Resetting the unitOperation Three Connection and ConfigurationConfiguring the Hardware Connection and Configuration Connecting the HardwareIPL M PDP-ES interface card configuration Connection and Configuration, cont’dConfiguring the IPL M PDP-ES using the ARP command Arp -s 10.13.170.15 00-05-A6-00-0A-90Configuring the IPL M PDP-ES using the RS-232 port Configuring the IPL M PDP-ES using direct PC connection192.168.254.253 Esc 10.13.170.15 CICommunication and Control Firmware upgradesNavigating the default Web pages Accessing and using the Web serverCommunication and Control Communication with the Interface CardPort Settings IP settings fieldsEmail Alerts PasswordsCommunication and Control, cont’d Esc 4 SM Firmware upgradeSending an email alert through Telnet File Management tab To add or update filesTo create a directory To delete unwanted files or directoriesPioneer tab PowerDisplay Status Display ControlsAdvanced Controls Monitor Energy SaveSchedule Symbol definitions Using the command/response tableCopyright information Password informationError responses Firmware Version/Part Number/Information PortDataBidirectional Serial File Commands IP Setup CommandsPassword and Security Settings Web Browser Specific DirectoriesRe-map port designations Telnet port Custom Web pagesDirect access port TroubleshootingIf status is missing or unavailable, check the following Specifications, Part Numbers, and AccessoriesSerial connections Parts SpecificationsGlossary Specifications, Part Numbers, Accessories, cont’dGlossary GlossaryGlossary, cont’d Glossary, cont’d

68-1021-01 specifications

Extron's electronic 68-1021-01 is a versatile and advanced presentation switcher that caters to the growing demands of modern multimedia environments. This device is designed to simplify the process of connecting various audio and video sources to a single output, making it ideal for classrooms, boardrooms, and other professional settings where seamless presentations are essential.

One of the main features of the 68-1021-01 is its ability to handle multiple video formats. It supports HDMI, Composite Video, and RGB inputs, allowing users to connect a diverse range of devices, from laptops and document cameras to legacy equipment. This multi-format capability ensures that users can integrate their existing technology without the need for extensive upgrades.

The switcher's advanced signal processing technology contributes to optimal video quality. It features built-in scaling capabilities, which adjust the resolution of incoming signals to match the output requirements. This ensures that the image quality remains sharp and crisp, regardless of the source, minimizing potential degradation that can occur during format conversions.

Another notable aspect of the Extron 68-1021-01 is its user-friendly interface. It provides an intuitive control mechanism that can be customized to fit the operational preferences of the user. The device can be managed via button inputs, remote controls, or even through third-party control systems, offering flexibility in how users interact with the system.

In addition to video capabilities, the 68-1021-01 is equipped with robust audio management features. It integrates audio switching and processing, which allows users to manage audio signals from various sources seamlessly. This is particularly beneficial in environments where audio clarity is crucial, such as in presentations or video conferences.

The 68-1021-01 utilizes Extron's renowned EDID (Extended Display Identification Data) technology, which helps ensure compatibility between the source and display devices. This feature automatically communicates the display's capabilities, optimizing the connection to reduce the risk of resolution or formatting issues.

Finally, the build quality reflects Extron's commitment to durability and reliability. The device is designed for easy installation, with options for rack mounting or desktop use, and features robust connections to withstand everyday use in busy environments.

Overall, the Extron electronic 68-1021-01 stands out as an efficient and reliable presentation switcher that combines advanced technology with user-friendly design, making it a valuable addition to any modern audiovisual setup.