APPLICATION MANUAL
The operational attentions to the use of the tantalum capacitors are as follows:
-Electrical
-Environmental
-Conditions for mounting on equipment and circuit boards
-Mechanical vibration, shock
If the tantalum capacitors are used without satisfying any one of these conditions, the probability of
●OPERATING VOLTAGE
▶The voltage derating factor should be as great as possible. Under normal conditions, the operating voltage should be reduced to 50% or less of the rating. It is recommended that the operating voltage be 30% or less of the rating, particularly when the tantalum capacitors are used in a low- impedance circuit (see Figs. 1, 2, and 3).
▶For circuits in which a switching, charging, discharging, or other momentary current flows, it is recommended that the operating voltage be 30% or less of the rating, with a resistor connected in series to limit the current to 300 mA or less.
▶When the tantalum capacitors are to be used at an ambient temperature of higher than 85℃, the recommended operating range shown in Fig. 3 should not be exceeded.
| Power supply filter | Power supply bypass | ||
| Power | + | + |
|
~ | supply | + | + | IC |
|
| |||
| circuit | - | - |
|
| Fig. | 1 | Fig. 2 |
|
100 |
|
|
|
|
|
|
|
|
80 |
|
|
|
|
|
|
|
|
60 |
|
|
|
|
|
|
|
|
40 |
|
|
|
|
|
|
|
|
20 |
|
|
|
|
|
|
|
|
0 | 0 | 20 | 40 | 60 | 85 | 100 | 125 | |
OPERATING TEMPERATURE
SCL Series