▷Soldering with a soldering iron
The use of a soldering iron should be avoided wherever possible. If it is
unavoidable, follow the instructions set forth in Table 5. The time of soldering with an iron should be one.
Table 5
350℃ MAX | |
|
|
Time | 3 sec MAX |
|
|
30 W MAX | |
|
|
▶Cleaning after Mounting
The following solvents are usable when cleaning the capacitors after mounting. Never use a highly active solvent.
-Halogen organic solvent (HCFC225, etc.)
-Alcoholic solvent (IPA, ethanol, etc.)
-Petroleum solvent, alkali saponifying agent, water, etc.
Circuit board cleaning must be conducted at a temperature of not higher than 50°C and for an immersion time of not longer than 30 minutes. When an ultrasonic cleaning method is used, cleaning must be conducted at a frequency of 48 kHz or lower, at an vibrator output
of 0.02 W/cm3, at a temperature of not higher than 40°C, and for a time of 5 minutes or shorter.
NOTE 1: Care must be exercised in cleaning process so that the mounted capacitor will not come into contact with any cleaned object or the like or will not get rubbed by a stiff brush or the like. If such precautions are not taken particularly when the ultrasonic cleaning method is employed, terminal breakage may occur.
NOTE 2: When performing ultrasonic cleaning under conditions other than stated above, conduct adequate advance checkout.
●OTHER
SCL Series
▷For further details, refer to EIAJ
▷If you have any questions, feel free to contact your local SAMSUNG