Samsung SP-L331 RS-232C Command Table, Communication Format Complies with the RS232C Standard

Page 66

5-2 RS-232C Command Table

Communication Format (Complies with the RS232C Standard)

Baud rate : 9,600 bps

parity : None

Data bits : 8, stop bit : 1

Flow Control : None

Serial Communication Protocol

1.Command Packet Structure [7bytes]

0x08

0x22

cmd1

cmd2

cmd3

value

CS

 

 

 

 

 

 

 

A command packet consists of 7 bytes in total.

The two bytes 0x08 and 0x22 signify that the packet is for serial communication.

The following 4 bytes represent a pre-defined command that can be defined by the user.

The last byte is the checksum which checks the validity of the current packet.

Header [2 Byte]: Pre-defined values fixed to 0x08 and 0x22.

Cmd1 [1 Byte]: The first value of the code defined in the command list (Hexadecimal)

Cmd2 [1 Byte]: The second value of the code defined in the command list (Hexadecimal)

Cmd3 [1 Byte]: The third value of the code defined in the command list (Hexadecimal)

Value [1 Byte]: Input parameter for the command (Default: 0) (Decimal)

CS [1 Byte]: Checksum (the 2’s complement of the sum of all the values except for the CS value.)

2.Response Packet Structure [3 Bytes] 1. Success

0x03

2.Fail

0x0C

0xF1

0x030x0C0xFF

When the received packet from an external device has a valid value, a Success packet is sent. Otherwise, a Fail packet is sent.

A Fail packet is sent if:

The received packet length is not equal to 7 bytes.

The 2 byte packet header value is not equal to 0x08, 0x22.

The check sum is incorrect.

Failure detection by an external device

An external device classifies the packet as Fail if it does not receive a Success packet within 100ms.

5-2

More Information

Image 66
Contents LCD Projector Table Of Contents Icons used in this manual Using this ManualBefore You Start Copyright NoticeCare and Maintenance Cleaning the Surface and the LensPower Related Safety PrecautionsIcons used for safety precautions Meaning of SignsInstallation Related Usage Related Major Safety Precautions Page Installation and Connection Package ContentsInstalling the Projector Leveling with Adjustable Feet Zoom and Focus Adjustment Screen Size and Projection Distance 548.6 Adjusting the H-Keystone and V-Keystone Installation and Connection Projector / B Screen / C Projected image Projector / B Screen / C Projected image Lamp Replacement Lamp Replacement ProcedureReplacing and Cleaning the Filter Ventilation openings Rear Side Setting up the PC Environment You do not have to change the Color quality setupInstallation and Connection Supported Display Modes PC Timing D-Sub/HDMIFormat Resolution Scan AV Timing D-SubAV Timing Hdmi AV Timing VIDEO/S-VIDEO Connecting the Power Connecting with a PC Connecting a PC using an HDMI/DVI cable Connecting an External Monitor Connecting an HDMI-Compatible Device Connecting an AV device using a D-Sub cable Connecting an AV device with component output Connecting using a Video/S-Video cable Connecting an External Speaker Connecting to a Network Connecting to a Dynamic IP Dhcp NetworkConnecting to a Static IP Network To use the network function, Network must be set to OnKensington Lock Locking the productUsing Product FeaturesFront, Upper Name DescriptionRemote Control Blank ButtonLED Indications LED IndicationsStand by Lamp Temp Status Clearing Indicator Problems Classifica State Measures TionPicture Using the Screen Adjustment Menu OSD On Screen DisplayInput Menu SUB-MENUText in a still picture appears unnatural This is not supported in AV and S-Video modes Setup Information to supplement information contained in Field1 Option Displayed for a minute whenever the projector is turned on Management using the Web Browser Network ManagementProjector Management using PC Software Using Icons Status State Measures Projectors internal temperature is Its normal Normal.low Managing the Projectors Page Using Troubleshooting Before Requesting ServiceScreen Network Specifications ModelMore Information RS-232C Command Table Communication Format Complies with the RS232C StandardSerial Communication Protocol Command Table Control Item CMD1 CMD2 CMD3 ValueControl Item CMD1 CMD2 CMD3 Value IRE/NOR Left Direct Fac Tory Reset Control Item CMD1 CMD2 CMD3 Value ไทย OFF Latin America Contact Samsung WorldwideNorth America EuropeCIS Asia PacificMiddle East & Africa Correct Disposal Europe only Correct disposal of batteries in this product Europe only