Samsung SRP275APG user manual EMC and Safety standards Applied, CE Marking

Page 3

SRP-275

All rights reserved. No part of this publication may reproduced, stored in a retrieval, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAMSUNG ELECTRO-MECHANICS.

No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this book, SAMSUNG ELECTRO-MECHANICS assumed no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein.

Neither SAMSUNG ELECTRO-MECHANICS nor its affiliates shall be liable to the purchaser of this product or third parties for damages, losses, costs, or expenses incurred by purchaser or third parties as a result of : accident, misuse, or abuse of this product or unauthorized modifications, repairs, or alterations to this product, or (excluding the U.S.) failure to strictly comply with SAMSUNG ELECTRO-MECHANICS s operating and maintenance instructions.

SAMSUNG ELECTRO-MECHANICS shall not be liable against any damages or problems arising from the use of any options or ant consumable products other than those designated as Original Samsung products or Samsung Approved products by SAMSUNG ELECTRO-MECHANICS.

------------------------------------------------------------------------------------------------------------------------------------------------

Notice

The contents of this manual are subject to change without notice.

Copyright© 2004 SAMSUNG ELECTRO-MECHANICS CO., LTD

------------------------------------------------------------------------------------------------------------------------------------------------

EMC and Safety standards Applied

Product Name : SRP-275

The following standards are applied only to the printers that are so labeled.

Europe :

CE marking, TUV/GS : EN60950-1; 2001

North America :

EMI : FCC Class A

Safety standards :

UL / C-UL : UL60950-1

National : CB-scheme : IEC 60950-1: 2001

------------------------------------------------------------------------------------------------------------------------------------------------

WARNING

The connection of a non-shielded printer interface cable to this printer will invalidate the EMC standards of this device. You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.

------------------------------------------------------------------------------------------------------------------------------------------------

CE Marking

The printer conforms to the following Directive and Norms

EMC Directive 89/336/EEC

EN55022 Class A : 1998+A1 : 2000

 

EN55024 : 1998:+A1 : 2001

 

EN61000-3-2

: 2000

 

EN61000-3-3

: 1995+A1 : 2001

Low Voltage Directive 73/23/EEC

Safety : EN60950-1 : 2001

Image 3
Contents USER’S Manual Page CE Marking EMC and Safety standards AppliedSafety precautions To Unplug Table of contents Appendix a Code table Appendix B ConnectorsRear view Front viewPage Page Choosing a place for the printer UnpackingConnect the AC adapter according to the following procedure Connecting the cablesConnecting the AC adaptor Connecting the interface cable and drawer kick-out cableInstalling the ribbon cassette Installing the paper roll Changing the paper width Installing the wall mount Option Paper OUT LED Red Color Using the operation panelControl panel Power LED Green Color Error LED Red ColorSelf test Error LED blinking pattern Recoverable errorsError Description Error LED blinking pattern Recovery If any of the lights are on, please check the following Printer does not start printingPrinter stops printing You want to check the operation of the printer by itselfSelf test Hexadecimal dump To use the hexadecimal dump feature, follow these stepsPrinting is poor You want to check a software programDIP Switch setting for EpsonESC/POS mode Setting the DIP SwitchInternational Character Selection DSW Code Country DIP Switch setting for CitizeniDP 3550 modeDIP Switch setting for StarSP500 mode Changing the DIP Switch setting Memory Switch Function Off Code page selection MSW Character TableOnly Font B available Serial communication Function Selectable value Customize value Function Selectable value Paper roll widthExample of Memory Switch setup sheet Memory Switch Setup ModeProcedure of Memory Switch setting Memory Switch setting for Star mode SettingsFunction Class Default Settings Precautions for selecting Option Function Memory Switch BitCountry Specifications MSW 0-4 = FF Command Function Selection MSWContextual Auto-cut Function Memory Switch Bit FunctionNear end switch Function MSW Near end switch FunctionCR Command Functions MSW3-1 MSW3-0 CR Ignored Character Table SettingsMSW3-9 MSW3-8 Character Table Once Explanation of term Command notationUndefined codes Undefined commandsSettings outside the defined range Exception processingCommands for SRP-275 series Commands list for Epson mode TM-U220Command Description Hex When auto line feed is disabled Command description for Epson mode TM-U220Bit Binary Hex Decimal Status FunctionStatus HexHex Decimal Function Connector pinDLE DC4 fn = BitESC % Density Mode Number of bits Dot densitySet Maximum number of dots Mode Dot DSW1-8 on HorizontalESC = ESC @ Font ESC JESC a ESC cJustification ESC e ESC dESC m ESC gESC g n ESCESC p ESC rESC t Hex Decimal Status ESC uPaper FS pFS q GS aFunction Description GS CFunction GS C p L p H m fn bReal-time command type GS DGS E GS E pL pH fn d1 d2 Function Setting value b FunctionType of customized value GS E p L p H fn a FunctionCommunication condition GS E p L p H fn a d1...dkBixolon Printer ID SpecificationHex Decimal Status for ASB Decimal Function GS r DC2 Commands list for Star mode SP500ESC L Command Description Hexadecimal Commands list for Citizen mode iDP3550/3551Description Remark Printing specificationPaper specifications Ribbon cassette specificationElectrical characteristics ReliabilityEnvironment conditions Weight Dimensions & weightOptional features DimensionsPage Appendix a Code tables 1 Katakana 2 PC850 Multilingual 3 PC860 Portuguese 4 PC863 Canadian-French 5 PC865 Nordic 16 WPC1252 Latin1 17 PC866 Russian 18 PC852 Latin2 19 PC858 Euro 21 PC862 Israel 22 PC864 Arabic 23 Thai character code 24 WPC1253 Greek 25 WPC1254 Turkish 26 WPC1257 Baltic 27 Farsi 28 WPC1251 Russian 29 PC737 Greek 30 PC775 Baltic 31 Thai character code 32 OldCode Israel 33 WPC1255 Israel 34 Thai character code 35 Thai character code International character code table 2 RS-232C Serial I/F signal descriptions RS-232C Serial I/FRS-232C Serial I/F cable connection IEEE1284 Parallel I/F Pin no Source Compatibility mode Nibble mode Byte modeDrawer kick-out cable connection USB I/F signal descriptionsPin No Signal name Assignment Color Function Drawer kick-outKN02-00009E Rev