Kramer Electronics user manual Connecting the VS-66HN 6x6 Hdmi Matrix Switcher

Page 12

5Connecting the VS-66HN 6x6 HDMI Matrix Switcher

i

Always switch off the power to each device before connecting it to your VS-66HN. After connecting your VS-66HN, connect its power and then switch on the power to each device.

To connect the VS-66HN 6x6 HDMI Matrix Switcher as illustrated in the example in Figure 3:

1.Connect up to six HDMI sources (for example, DVD players) to the IN HDMI

connectors.

You do not have to connect all the sources.

2.Connect the six OUT HDMI connectors to up to six HDMI acceptors (for

example, LCD displays with built-in speakers).

You do not have to connect all the outputs.

3.If required, connect a PC/controller to the RS-232 port (see Section 6.6) and/or the Ethernet port (see Section 6.7).

4.Connect the device to the mains electricity (not shown in Figure 3).

5.If necessary, acquire the EDID (see Section 6.2)

VS-66HN - Connecting the VS-66HN 6x6 HDMI Matrix Switcher

9

 

 

Image 12
Contents VS-66HN Page Figures Introduction Getting Started Achieving the Best PerformanceSafety Instructions Recycling Kramer Products Defining the VS-66HN 6x6 Hdmi Matrix Switcher OverviewVS-66HN Overview Reset Button Using the IR Transmitter Installing in a Rack Connecting the VS-66HN 6x6 Hdmi Matrix Switcher Connecting the VS-66HN 6x6 Hdmi Matrix Switcher Operating the VS-66HN 6x6 Hdmi Matrix Switcher Switching an Input to an OutputAcquiring the Edid Acquiring the Edid from One Output Selected input number flashes on the displayStoring and Recalling a Preset Acquiring the Default EdidResetting the IP Parameters To store a preset for example, to presetSwitching Between Protocol 2000 and Protocol Connecting via RS-232Connecting via the Ethernet Connecting the Ethernet Port directly to a PC Local Area Connection Properties WindowInternet Protocol Version 4 Properties Window Internet Protocol Version 6 Properties Window Connecting the Ethernet Port via a Network Hub or Switch Control Configuration via the Ethernet PortUpgrading the Firmware Technical Specifications Default Communication Parameters RS-232Default Edid KMR720x480p at 60Hz 0.0 Kramer Protocol Machine NumberInstruction Codes for Protocol VS-66HN Kramer Protocol Protocol Kramer Protocol 3000 SyntaxHost Message Format 11.1.2 Device Message FormatCommand Terms Device Long ResponseEntering Commands Command FormsChaining Commands Maximum String LengthKramer Protocol 3000 Commands Short Command Form Description PermissionPage Safety Warning