Kramer Electronics VS-66HN user manual Default Communication Parameters, RS-232

Page 24

8 Default Communication Parameters

RS-232

Protocol 2000 (Default)

Protocol 3000

 

 

 

Baud Rate

 

 

9600

Baud Rate

 

9600

 

Data Bits

 

 

8

Data Bits

 

8

 

 

 

 

 

 

 

 

 

 

 

Stop Bits

 

 

1

Stop Bits

 

1

 

Parity

 

 

None

Parity

 

None

 

 

 

 

 

 

 

 

Command Format

HEX

Command Format

ASCII

 

 

 

 

 

 

 

 

Example (Output

0x01, 0x81, 0x81, 0x81

Example (Output 1 to

#VID1>1<CR>

1 to Input 1)

 

 

 

Input 1)

 

 

 

 

 

 

 

 

 

 

 

 

Switching Protocol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2000 –> P3000

 

 

 

P3000 –> P2000

 

 

 

 

 

 

 

 

 

 

Command

 

0x38, 0x80, 0x83, 0x81

Command

 

#P2000<CR>

 

 

 

 

 

 

 

Front Panel

 

Press and hold Output 1 and

Front Panel

 

Press and hold Output 1

 

 

Output 3 simultaneously

 

 

and Output 2 simultaneously

 

 

 

 

 

 

 

 

 

Ethernet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IP Address

 

 

192.168.1.39

TCP Port

 

5000 or 10001 or 50000

Subnet Mask

 

 

255.255.255.0

UDP Port

 

50000

 

 

 

 

 

 

 

 

 

 

 

 

VS-66HN - Default Communication Parameters

21

 

 

Image 24
Contents VS-66HN Page Figures Introduction Getting Started Achieving the Best PerformanceSafety Instructions Recycling Kramer Products Defining the VS-66HN 6x6 Hdmi Matrix Switcher OverviewVS-66HN Overview Reset Button Using the IR Transmitter Installing in a Rack Connecting the VS-66HN 6x6 Hdmi Matrix Switcher Connecting the VS-66HN 6x6 Hdmi Matrix Switcher Operating the VS-66HN 6x6 Hdmi Matrix Switcher Switching an Input to an OutputAcquiring the Edid Acquiring the Edid from One Output Selected input number flashes on the displayStoring and Recalling a Preset Acquiring the Default EdidResetting the IP Parameters To store a preset for example, to presetSwitching Between Protocol 2000 and Protocol Connecting via RS-232Connecting via the Ethernet Connecting the Ethernet Port directly to a PC Local Area Connection Properties WindowInternet Protocol Version 4 Properties Window Internet Protocol Version 6 Properties Window Connecting the Ethernet Port via a Network Hub or Switch Control Configuration via the Ethernet PortUpgrading the Firmware Technical Specifications Default Communication Parameters RS-232Default Edid KMR720x480p at 60Hz 0.0 Kramer Protocol Machine NumberInstruction Codes for Protocol VS-66HN Kramer Protocol Protocol Kramer Protocol 3000 SyntaxHost Message Format 11.1.2 Device Message FormatCommand Terms Device Long ResponseEntering Commands Command FormsChaining Commands Maximum String LengthKramer Protocol 3000 Commands Short Command Form Description PermissionPage Safety Warning