Performance Series DVR User Guide
Sequence Setup
The Sequence Setup display allows the user to set the parameters for:
Page Dwell Time - 1 ~ 100 seconds [Set the sequence interval time for full screen on Main Display]
Camera Dwell Time - 1 ~ 100 seconds [Set the sequence interval time for individual cameras on Main Display]
Channel - 1 ~ 16 / All [Select cameras to display in Main Display]
SPOT Setup
The SPOT Setup display allows the user to define the sequence display for individual Spot Monitors. This allows users to use different Spot Monitors to display only the video necessary for the person watching the Spot Monitor.
Sequence - On/Off [sequences through selected cameras] Interval – 1 ~ 60 seconds [Set the sequence interval time]. Channel - Select cameras to include in sequence.
Record Setup
Time Setup
Day/Night/Weekend – Adjust the FPS and picture quality for each schedule individually.
[C]FPS – 0 ~25 [Define a global FPS setting for continuous recording or set individually for each channel.]
[M]FPS – 0 ~25 [Define a global FPS setting for motion/event recording or set individually for each channel.]
Record Mode – Continuous / Motion Event / C/M/E[ALL] /N/A
Quality – Low / Normal / High / Ultra [Define a global quality setting or set individually for each channel.]
Post Recording – 0 99 seconds [Recording time after event.]
Continuous Frame
Event Frame – Displays the actual FPS / maximum FPS for event recording.
______________________________________________________________________________________________