Mounting the Scaler

UL rack mounting requirements

The following Underwriters Laboratories (UL) requirements pertain to the safe installation of the IN1502 in a rack.

1.Elevated operating ambient temperature — If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, install the IN1502 in an environment compatible with the maximum ambient temperature (Tma = +113 °F, +45 °C) specified by Extron.

2.Reduced air flow — Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised.

3.Mechanical loading — Mount the equipment in the rack so that a hazardous condition is not achieved due to uneven mechanical loading.

4.Circuit overloading — Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

5.Reliable earthing (grounding) — Maintain reliable grounding of rack- mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (e.g. use of power strips).

Tabletop/desktop placement

For tabletop or desktop placement only, install the self-adhesive rubber feet/pads (provided) onto the four corners of the bottom of the enclosure.

Rack mounting

1. If feet were installed on the bottom of the IN1502, remove them.

2. Place the IN1502 on one half of the 1U (one unit high, one unit wide) rack shelf (part #60-190-01 or #60-604-01). Align the front of the IN1502 with the front of the shelf, and align the threaded holes on the bottom of the IN1502 with the holes in the rack shelf.

3. Attach the IN1502 to the rack shelf with the two provided 4-40 x 3/16" machine screws. Insert the screws from the underside of the shelf, and securely fasten them into diagonally-opposite corners.

See the following illustration.

2-2 IN1502 • Installation and Operation

Image 14
Contents IN1502 Precautions FCC Class a Notice Page Rear panel video output O Scaler Output Resolutions and RatesRear panel video inputs Application exampleQS-2 IN1502 Quick Start Table of Contents Table of Contents, cont’d One About the IN1502 Features and OptionsAbout this Manual Options and accessories Introduction, cont’d Installation and Operation Mounting the Scaler Tabletop/desktop placementIN1502 Installation and Operation UL rack mounting requirementsRack mounting the IN1502 Installation and Operation, cont’d Application diagramRear Panel Features IN1502 rear panel connectorsNext button Front Panel FeaturesInput selection buttons Menu buttonMenu overview Menus, Configuration, and AdjustmentsMoving through menus by using front panel controls Main menus Picture Control 10 IN1502 Installation and Operation Output ConfigurationResolution and refresh rates Sync polarityAutoswitch Autosw mode Advanced ConfigurationBlue mode Top and bottom blanking12 IN1502 Installation and Operation Setting up a DVD sourcePulldown detection PAL film mode detect submenu Optimizing the System for a DVD PlayerFront Panel Security Lockout Executive Mode Input ResetSystem Reset Freeze an input IR 901 Infrared Remote ControlImage adjustments Select an inputTroubleshooting Operating problems16 IN1502 Installation and Operation Three Host-to-scaler communications Error responsesRS-232 Programmer’s Guide Scaler-initiated messagesUsing the command/response tables Symbol definitionsCommand Ascii Command Response Additional description Serial Communication, cont’dHorizontal shift Part number request Command/response table for special function SIS commands Command Ascii Command Response ValuesSerial Communication, cont’d AAppendix Specifications IN1502 AppendixGeneral Accessories Part number Part Numbers and AccessoriesAccessories Included partsFirmware Upgrade Installation U17 U38 U41 Extron’s Warranty Extron Electronics, Europe Beeldschermweg 6C