Bosch Appliances GWH-635-ESO, 2400ES, 2700ES, 715ES Remote control transceiver PCB installation

Page 5

Remote control installation

4Remote control installation for: GWH- 635-ES/GWH-635- ESO/250SX/250SXO/ 2400E/2400EO

4.1Remote control transceiver PCB installation

Warning: For safety reasons, disconnect the power supply to the water heater before performing installation.

Pre-installation preparation

BDisconnect power supply to heater.

B Remove plastic decals on front panel.

B Loosen two Philips head screws located behind plastic decals.

BLift front cover upward and remove.

Fig. 2

B Remove the 5 screws on the front retaining bar (see Fig. 2, pos. 1 and

2)being careful not to damage the foam sealant material on it.

B Remove control unit auxiliary cover (Fig. 2, pos. 4).

B Remove the two electrical strip connectors inside the auxiliary cover (Fig. see diagram below) and then loosen the 110V power supply cord retaining nut located underneath the heater. Once loosened, the power cord can be pulled up through the heater to provide sufficient slack.

6 720 606 990

5

Image 5
Contents Bosch Remote Control Contents FCC Declaration of conformity Safety instructionsSafety instructions Remote control Kit Remote control dataRemote control data Parts suppliedPre-installation preparation Remote control transceiver PCB installationRemote control installation Remote control transceiver PCB installation Support correct position Activation Remote controlTo determine Version in the water heaterSU board Before performing installation Remote control activation Remote control installation Hot water temperature adjustment by remote control Remote controlProgram button on the remote control Remote controlMemorizing water temperature Acquiring priority Priority functionError messages TroubleshootingCleaning TroubleshootingOr concrete Structure Remote will not memorize desired temperature setting Priority symbol will not clear720 606