Bosch Appliances 2700ES, GWH-635-ESO, 2400ES, 715ES, C800ES manual Support correct position

Page 7

Remote control installation

B Replace the control unit cover with the 4 Philips head screws (Fig. 3, pos. 1).

B Slide control unit back into heater.

B Plug 2 yellow electrode wires from the top of the control unit back onto the ignition electrodes. Ensure all connections are secure and tight (Fig. 2, pos. 3).

i

Wire polarity does not

matter on the electrode

 

 

wires.

Fig. 4 Support correct position

BUse the supplied cable to connect between the main PCB and the remote control PCB as shown in Fig. 5.

B Pull end of power cord to take up excess slack and tighten retaining nut on the bottom of the heater.

B Reinstall the two electrical strip connectors onto the PCB. The larger connector connects to the lower connection on the PCB. Reseat the rubber seals for both connectors.

B Replace the control unit auxiliary cover. (Fig. 2, pos. 4).

BReplace front retaining bar using 5 Phillips head screws. (Fig. 2, pos 1).

Fig. 5

6 720 606 990

7

Image 7
Contents Bosch Remote Control Contents Safety instructions Safety instructionsFCC Declaration of conformity Parts supplied Remote control dataRemote control Kit Remote control dataRemote control installation Remote control transceiver PCB installationPre-installation preparation Remote control transceiver PCB installation Support correct position Version in the water heater Remote controlActivation To determineSU board Before performing installation Remote control activation Remote control installation Remote control Remote controlHot water temperature adjustment by remote control Program button on the remote controlMemorizing water temperature Acquiring priority Priority functionTroubleshooting TroubleshootingError messages CleaningOr concrete Structure Remote will not memorize desired temperature setting Priority symbol will not clear720 606