Bosch Appliances C800ES, GWH-635-ESO, 2400ES, 2700ES, 715ES manual SU board

Page 9

Remote control installation

B Switch power switch on the appliance to the "OFF" (0) position and then back "ON" (I).

B Press buttons or in order to reach desired temperature.

New remote control is programmed.

4.2.2 SU board

BConnect power to heater.

B Move the main switch on the appliance to the "OFF" (0) position.

BPress and hold key while at the same time turning the main switch to “ON” position (I).

LCD shows one number and one

rotating digit. If not repeat previous

step.

The number represents the remote

control which is to be registered, the

first remote control will be registered

with number “0”, the second with

number “1” and so on.

The rotating digit shows that the

electronics is expecting a registration.

If the LCD fails to show a number and

rotating digit after repeated attempts,

double check the wire connections

made in section 4.1.

B Hold remote control in front of the control panel on the heater and

simultaneously press remote control

buttons and until the temperature indication is shown on the remote control LCD.

B Switch ON/OFF switch to “OFF” position (0) and then back on (I).

B Press buttons or in order to reach requested temperature.

New remote control is programmed.

6 720 606 990

9

Image 9
Contents Bosch Remote Control Contents Safety instructions Safety instructionsFCC Declaration of conformity Remote control Kit Remote control dataRemote control data Parts suppliedRemote control transceiver PCB installation Remote control installationPre-installation preparation Remote control transceiver PCB installation Support correct position Activation Remote controlTo determine Version in the water heaterSU board Before performing installation Remote control activation Remote control installation Hot water temperature adjustment by remote control Remote controlProgram button on the remote control Remote controlMemorizing water temperature Acquiring priority Priority functionError messages TroubleshootingCleaning TroubleshootingOr concrete Structure Remote will not memorize desired temperature setting Priority symbol will not clear720 606