2MENU-SPECIFIC SETTINGS
5. RECORDING CONDITIONS SET
Set the permission for overwriting to recording areas or the
1
2
3
4
5
Setting overwriting permission for the normal recording area
When the normal recording area has been filled with data, this setting dictates whether recording will be stopped or continued by overwriting the recorded images currently stored on the hard disk.
1 Select “OVERWRITE” for normal recording area from the
[Settings] ( indicates default setting.)
Setting | Description | |
| When the normal recording area has been filled with | |
ON | data, overwriting from the beginning of this area will | |
| start automatically. | |
|
| |
OFF | Recording is stopped when the normal recording area | |
has been filled with data. | ||
| ||
|
|
Setting overwriting permission for the alarm recording area
When the alarm recording area has been filled with data, this setting dictates whether recording will be stopped or continued by overwriting the recorded images currently stored on the hard disk.
2 Select “OVERWRITE” for alarm recording area from the
[Settings] ( indicates default setting.)
Setting | Description | |
| When the alarm recording area has been filled with | |
ON | data, overwriting from the beginning of this area will | |
| start automatically. | |
|
| |
OFF | Recording is stopped when the alarm recording area | |
has been filled with data. | ||
| ||
|
|
Setting the remaining-space warning level
In situations where the overwrite setting for the normal |
| |
recording area and the alarm recording area is “OFF”, you |
| |
can have the unit issue a warning as soon as the |
| |
remaining space in either of these areas reaches a specific |
| |
level. (JP. 21) |
| |
The following section describes how to set the level at |
| |
which the warning will be issued. |
| |
(This level is common for the normal recording area and | NETWORK SETTINGS | |
the alarm recording area.) | ||
|
3 Set the
Setting range: 1% to 10% (in units of 1%)
Setting the auto delete
You can set the storage period for images. When the set period has expired, the corresponding data will be automatically deleted.
4 Set “AUTO DELETE” from the pull-down menu on the screen.
[Settings] ( indicates default setting.)
Setting | Description |
OFF | Auto delete is not to be set |
|
|
1 | You can set the storage period for recorded data |
DAYS | within a range of “1 DAY” - “99 DAYS” (full days). |
|
|
zIf the overwrite setting for the normal recording area and the alarm recording area is “ON”, the remaining- space warning level will be displayed as “**” and setting will not be possible.
5 Click [SAVE].
The new setting is saved.
14 | English |