Installation to a concrete wall

WARNING

When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete surface in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica- tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the wall will safely support four times the combined load of the equipment and all attached hard- ware and components.

Drill two 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach support arm (A) using concrete anchors(call customer service to order accessory kit ACC 200 or ACC203) and #14 x 2.5" wood screws (F) as shown in Illustration A and 1, 2, and 3. Tighten all fasteners.

WARNING

Tighten wood screws firmly, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.

Never tighten in excess of 80 in • lb (9 N.M.).

concrete anchor

A

F

Illustration A

WARNING

Concrete anchors are not intended for attachment to concrete wall covered with a layer of plaster, drywall, or other finishing material. If mounting to concrete wall covered with plaster/drywall is unavoidable, plaster/ drywall (up to 5/8" thick) must be counterbored as shown right. If plaster/drywall is thicker than 5/8", custom fasteners must be supplied by installer.

1

 

concrete

 

 

wall

 

 

concrete

 

 

anchor

Drill hole and insert anchor

 

2

A

 

 

F

concrete

 

anchor

Place wall plate over anchor and secure with screw

3

 

 

 

F

concrete

 

anchor

 

 

After repeating step one tighten all fasteners

 

INCORRECT

 

 

metal

 

concrete

 

bracket

 

 

VIEW

 

dry wall

 

CUTAWAY

 

plaster/

 

 

CORRECT

 

 

 

metal

 

 

 

bracket

 

concrete

 

 

plaster/

 

 

 

dry wall

 

4 of 6