AUDIO TOWER REPLACEMENT |
4.Application Software Installation
If necessary, obtain C3 Maestro application software V5.0 (or later).
Install this software on PC's hard disk drive in Gaccordance with the supplied instructions.
Optional: Delete the old C3 Maestro application software from the PC's hard disk drive.
5.
Normally, no
6.
If using existing modular cabling, cut the modular plugs off modular cables. Maintain connections to the CEC/IMC Audio Concentrator Card or punch blocks. Next, wire these audio lines to a male
G(begins on page 14) for additional information.
If using the
7. DispatchGKeyboard
The existing (old) Dispatch Keyboard was disconnected in step 1. If a new Dispatch Keyboard (with male
Table 9 – Dispatch Keyboard Cable
Color Coding
| MALE | CABLE |
|
| WIRE | USE | |
| NUMBER | COLOR |
|
|
|
|
|
|
|
|
|
| 1 | red | dc power |
|
|
|
|
| 2 | white | keyboard data |
|
|
|
|
| 4 | green | ground |
|
|
|
|
G | 6 | (bare) | shield |
|
|
|
|
|
|
|
|
Connect the Dispatch Keyboard to the Enhanced Audio Enclosure in accordance with subsection entitled "Dispatch Keyboard" in this manual (page 18).
8. MicrophonesG & Headsets
Connect existing mics and headset jack boxes to the Enhanced Audio Enclosure per section
"INTERCONNECTING THE EQUIPMENT",
subsection "ENHANCED AUDIO ENCLOSURE" in this manual (begins on page 18). No wiring changes are necessary.
9.FootswitchesG
Audio Tower "FOOTSWITCH 1" should now be used as an operator footswitch. Connect it to Enhanced Audio Enclosure's "OPER FT. SW." connector. This footswitch keys all
Gdetails.
Audio Tower "FOOTSWITCH 2" should now be used as a supervisor footswitch. Connect it to Enhanced Audio Enclosure's "SUPER FT. SW." connector. This footswitch keys only the supervisor's headset.
10. Speakers
Speakers used with the Audio Tower are
24