Sequence of Events
1.The Local
2.The Remote
3.Built In Link Test data is sent from the Local
4.The Remote
5.If the PWR LED on the Local C/CM media converter module blinks red, this connection may require further testing. The PWR LED should flash green to indicate that there have been no errors in the last second.
6.The Built in Link Test continues to run until Switch 1 on the Local
Fiber Fault Alert (Switch 3 – Data Mode)
Switch Position | Mode |
|
|
Up (default) | Enabled |
|
|
Down | Disabled |
|
|
Enabled: If the media converter module detects a loss of signal on the fiber port, the media converter module notifies the link partner on that same port that an error condition exists by bringing down the link.
Disabled: The media converter module will not monitor for fiber fault.
Perle | 7 |