Perle Systems C-10GT-SFP, C-10GT-XFPH Sequence of Events, Fiber Fault Alert Switch 3 Data Mode

Page 7

Sequence of Events

1.The Local C/CM-10GT media converter module sends the Remote C/CM-10GT media converter module a signal to go into test mode.

2.The Remote C/CM-10GT media converter module turns on test mode.

3.Built In Link Test data is sent from the Local C/CM-10GT media converter module to the Remote C/CM-10GT media converter module.

4.The Remote C/CM-10GT media converter module analyses the received test data and sends its own test data plus a diagnostic code back to the Local C/CM media converter module.

5.If the PWR LED on the Local C/CM media converter module blinks red, this connection may require further testing. The PWR LED should flash green to indicate that there have been no errors in the last second.

6.The Built in Link Test continues to run until Switch 1 on the Local C/CM-10GT media converter module is set to Data mode.

Fiber Fault Alert (Switch 3 – Data Mode)

Switch Position

Mode

 

 

Up (default)

Enabled

 

 

Down

Disabled

 

 

Enabled: If the media converter module detects a loss of signal on the fiber port, the media converter module notifies the link partner on that same port that an error condition exists by bringing down the link.

Disabled: The media converter module will not monitor for fiber fault.

Perle C/CM-10GT Media Modules Installation Guide

7

Image 7
Contents Perle 10GT Media Converter Modules Installation Guide Model Port Type OverviewFront View Getting to know your C/CM-10GT Media ConverterCM-10GT-SFP or C/CM-10GT-XFPH Link Mode Switch 2 Data Mode Operating Mode SwitchSwitch Position Mode Switch Position Type Test Function Switch 2 Test ModeIllustration of the Built In Link Test Sequence of Events Fiber Fault Alert Switch 3 Data ModePort Selection Switch 3 Test Mode Fiber Fault Alert Sample ConfigSwitch Position Port EEE Energy Efficient Ethernet Installing ModulesAUTO-Config Jumper CM models only Status LED PWR Power/TestRed blinking slowly while in Test mode indicates an error OperationLK1- Port 1 Activity LK1 LK2 Error CodesLK2 Port 2 Activity General TroubleshootingNo connectivity Loopback Test Module Temperature ProtectionCopper Cable Requirements Technical SpecificationsSFP+ and Xfph Feature Set Fiber Cabling RequirementsCompliance Information Warranty / RegistrationContacting Technical Support