5.13 External Alarm Input and Relay Output
For
External alarm input setup:
Step 1:Select one alarm input
Use【↑】【↓】keys to select one alarm input.
Step 2:Alarm type
This is sensor type. You can select “Normal Open” or “Normal Close” according to the sensor type.
Step 3:Enter into “Alarm in Handling” sub menu
In the “Alarms” menu, there are two options for “Alarm Handling” item. One is “Ignore”, and the other is “Handle”. If you select “Handle” option, you can active “Policy” and “PTZ Linkage” buttons on right side. Move “Active Frame” to “Policy” button and press【ENTER】 key, you will enter into “Alarm in Handling” sub menu: