5.3Unit Name and Device ID

Unit name

In the “Display” menu

There is an item named “Unit Name”. The default unit name is “Embedded Net DVR”. Move “Active Frame” to unit name edit box, pressEDITkey to enter into edit status, you can modify the unit name. About how to input characters, please refer to chapter 3.4. Press ENTERkey to finish modification. Select “Confirm” button and pressENTER, you can save the new unit name and make it into effect. Press “Cancel” button orESCkey to abort modification.

Device ID

When you use IR controller to operate DVR, you must use device ID to select DVR. The default device ID of DVR is “88”. If there are more than one DVR in one place, please define different device ID for each DVR. Otherwise, the IR controller will control all DVR with the same device ID at the same time.

In “Display” menu, move “Active Frame” to the device ID edit box, in the edit status, you can use numeric keys to input new device ID. The device ID value is ranged among 01-100. After you finish the modification, press “Confirm” button to save and take effect or press “Cancel” to abort modification.

Page 39

Image 39
Contents USER’S Manual Copyright Weee regulation SafetyContent Appendix B Compression FeaturesProduct Introduction SummaryNetwork AlarmsPreview and playback OthersInstallation Checking the DVR and Its AccessoriesHDD Installation Rear Panel Description External Alarm In/Out Connection Operational Instructions Front PanelType Name Description REC Index Name Description IR ControllerLoading the batteries into the IR controller Stop using IR controllerSwitch the DVR off When IR controller can not work normallyMenu Description Main Menu Description How to enter into menu modeTransaction UtilitiesHow to exit menu Character Input Power on Basic Operation GuidePreview Icon Icon Color Status Description Camera alarm status is following: User name and password LoginModify password Page PTZ control keys description PTZ ControlPTZ control interface Select channelAdjust preset description Start/Stop auto in PTZ control modeExit PTZ control mode Manual Record Manual recordExit manual record Playback interface PlaybackThree kinds of playback mode Operation when playback Exit playback Backup intraday recorded files Backup Recorded FilesBackup video segment :Select the files that you want to backup:Select backup device :Start and finish backupShut Down DVR Use【POWER】key of front panel or IR controllerShut down DVR abnormally Use the power switch of real panel Take away the power cableParameters Setup Guide Administrator and PasswordPassword modification Page Add and Delete User User rights description Local Rights: :Save the new user’s password and rightsRemote Play Remote Rights:MAC address Locoal PlayUnit Name and Device ID Unit nameDevice ID: Video Output Standard and VGA Setup VGA setupVideo output standard OSD Setup System TimeDisplay System Time Camera Name Setup Camera Name Position :Enter into Image Setup menu: Video Parameters SetupMask Area Setup Page :Enter into Image Setup memu: View Tampering AlarmPage Video Loss Alarm Page :Select camera:Use【Ç】【È】key to select one camera Motion Detection AlarmClear motion area: Please refer to .12 for recording setup :Preview properties: Preview PropertiesPage Recording menu description: Recording SetupPage :Copy to other days :Select ond day and enable all day recording optionNone all day recording setup :Record type:Setup time period and record type :Select ond day and disable all day recording option:Enter into Alarm in Handling sub menu External Alarm Input and Relay OutputExternal alarm input setup: :Select one alarm input :Alarm type:Save setup :Alarm trigger record channel setup:Schedule for alarm handle method :Alarm handle method:Copy the parameters to other external alarm input Alarm relay output setup:Select delay time :Enter into alarm out schedule :Setup alarm out schedule:Copy one alarm output parameters to other alarm output Network menu description: Network Parameters15 PTZ PTZ menu description Sequence setup Preset setupCruise setup Page RS232 menu description 16 RS232 setupExample:PPP Modem passive dialup through Pstn Setup at DVR endSetup should be specially pay attention to: Page :Establish the dialup connection Exceptions Transaction Information Page Receive the command sent by ATM through serial port Page Restore Parameters UtilitiesSave Parameters Upgrade Hard Disk Management Clear Alarm OutReboot Power OffBy Type For example:The steps of viewing alarm logBy Type&Date By TimeSystem Information FTP Server Setup Firmware UpgradePage Page Upgrade Mode Pin definition Appendix a DVR Connect Cable DefinitionUTP network connect cable made method Material and toolRS-232 connect cable made method Model name DVR-470 Appendix B SpecificationsPower supply 100~240VAC, 6.3A, 50~60 HZ USB CD-R/W: Appendix C List of Recommended DVR PeripheralsPage Type Name Description Index Appendix D Quick Search Function TableOSD Failure Possible reasons Appendix E Troubleshooting