Sony GDM-F500T9 service manual Adjustments, ∙ Landing Fine Adjustment

Page 21

SECTION 4

GDM-F500/F500T9

ADJUSTMENTS

Note: Hand degauss must be used on stand-by or power-off condition.

This model has an automatic earth magnetism correction function by using an earth magnetism sensor and a LCC coil. When using a hand degauss while monitor (LCC coil) is being operated, it sometimes gets magnetized, and the system may not work properly as a result.

Landing Rough Adjustment

1.Enter the full white signal. (or the full black dots signal).

2.Adjust the contrast to the maximum.

3.Make the screen monogreen.

Note: Off the outputs from R ch and B ch of SG.

4.Reverse the DY, and adjust coarsely the purity magnet so that a green raster positions in the center of screen.

5.Adjust the tilt of DY, and fix lightly with a clamp.

Note: “TILT” shall be set at 128.

Landing Fine Adjustment

1.Put the set inside the Helmholtz coil. (“LCC SW” = “12”)

2.Input the single green signal and set the CONT control to MAX.

Note: After the W/B adjustment with 9300K, measure an aver- age of ΣIk when a full white signal is entered in the CONT MAX/BRT CENT status. Then make adjustment so that

<Specifications>

Adjust so that the green is within the specification given right. Adjust target : within ± 1

The red and blue must be within the specification given right with respect to the green.

A difference between red and blue must be within the specification given right.

 

 

 

 

 

 

(µm)

 

 

 

 

 

 

 

 

 

 

0 ± 3 0

± 7.5

0 ± 3

 

 

 

 

 

 

0 ± 5

0

± 5

0 ± 5

 

 

 

0 ± 3 0

± 7.5

0 ± 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(µm)

 

± 6

 

± 6

±

6

 

 

 

 

 

 

 

± 6

 

± 4

± 6

 

 

 

± 6

 

± 6

± 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(µm)

 

10

 

10

 

10

 

 

 

 

 

 

 

10

 

7

10

 

 

 

10

 

10

10

 

 

 

 

 

 

 

 

 

 

 

the specified screen can be attained after aging for 2 hours with Ik equivalent to 30% of the average value.

3.Demagnetize the metal part of the chassis with the hand de- gausser and coil degausser, and the CRT surface with the hand degausser.

Input AC 230V to AC IN, turn on and off the power to per- form auto degaussing. (Perform auto degaussing by setting “MON CON REG2”=152. Return to the original value after

use.)

Demagnetize the CRT surface with the hand degausser again.

Note:

(1)Hand degauss must be used on stand-by or power-off condi- tion.

This model has an automatic earth magnetism correction function by using an earth magnetism sensor and a LCC coil. When using a hand degauss while monitor (LCC coil) is be- ing operated, it sometimes gets magnetized, and the system may not work properly as a result.

(2)Adjust in a non-magnetic field. BV=45uT.

(3)If adjusting in a magnetic fields, add the shift from the non- magnetic field in your estimation.

4.Attach the wobbling coil to the designated part of the CRT neck.

5.Attach the sensor of the landing adjustment unit on the CRT surface.

6.Adjust the DY position and purity, and the DY tilt, and land- ing of the center and 4 corners with the landing checker.

Write terrestrial magnetism sensor reading VX and VY to “LCC VX” and LCC VY” respectively. Adjust the land- ing by moving “LCC NS”, “LCC LT”, “LCC LB”, “LCC RT” and “LCC RB”. However, the register adjustment

must be limited within the following range.

“LCC NS”128 ± 15 “LCC LT”, “LCC LB”, “LCC RT”, “LCC RB”

128 ± 40

After adjustment, set “LCC SW” to “13” and save the ser- vice data.

*Adjustment and measurement should be made at the points one inch inside the fluorescent screen.

7.Insert wedges to make the DY neck stand upright without moving it.

At this time, without shaking the DY, firmly insert the wedges.

8.Check the landing of each corner, and if it does not satisfy the specification, adjust the landing of four corners using “LCC LT“, “LCC LB”, “LCC RT” and “LCC RB”.

However, the register adjustment must be limited within the following range.

“LCC NS”128 ± 15 “LCC LT”, “LCC LB”, “LCC RT”, “LCC RB”

128 ± 40

After adjustment, save the service data.

If it does not yet satisfy the specification, paste a Disk-Mg onto the funnel and adjust.

Note:

(1)Do not paste more than two magnets on one corner.

(2)Magnets will be placed in a range 80 ~ 100 mm from the DY along diagonal lines.

(3)After placing magnets, absolutely hand degauss and check the results. (Hand degauss must be used on stand-by or power-off condition.)

9.Remove the sensor and wobbling coil.

10.Switch the signal to R.G.B., and check that each color is pure.

11.Check that the DY is not tilting, and fix the purity Mg with a white pen.

4-1

Image 21
Contents GDM-F500/F500T9 Leakage Test Safety CHECK-OUTTo change the power saving delay time Power Saving FunctionTiming Specification Table of Contents Section PrecautionsGeneral Identifying parts and controlsConnect the power cord Connect your monitor to your computerTurn on the monitor and computer Selecting the input signal Connecting Universal Serial Bus USB compliant peripheralsSelecting the on-screen menu language Lang Automatically sizing and centering the pictureAdjusting the size of the picture Size Adjusting the brightness and contrastNavigating the menu Picture CenterAdjusting the color of the picture Color Adjusting the shape of the picture GeomAdjusting the quality of the picture Screen Enlarging or reducing the pictureResetting the adjustments Additional settings OptionPreset and user modes If thin lines appear on your screen damper wiresSymptom Check these items Picture is ghosting Trouble symptoms and remediesSelf-diagnosis function If the 1 power indicator is greenSection Disassembly Cabinet RemovalBoard Removal Screw + Bvtt 4 x Two screws + Bvtt 4 x Service Position US Board Removal H1, H2 and J Boards RemovalGND DY Picture Tube RemovalFBT Harness Location+ Voltage Check Section Safety Related Adjustment∙ Landing Fine Adjustment AdjustmentsMode ∙ Convergence Rough AdjustmentBlock Diagrams Section DiagramsPage 5BNC Video AMP, RGB OUT Frame Schematic DiagramSchematic Diagrams and Printed Wiring Boards Circuit Boards LocationBoard Component Side Focus 1/2 D 2/2 board JL boards l Schematic diagramsPower Supply Schematic diagram Board lSTAT, H.STAT, LCC GEO Magnetic Sensor Video AMP Videorgb Outamp GND3 Schematic diagram Us board lUSB Control F500 AEPS/N 2,801,281 and laterUS Board Conductor Side Schematic diagram Semiconductors EGP10GPKG23 2SC4686A Lbsony EGP10DD2S4MF D2S4MTA1 FMQ-G5GS D5L60Exploded Views ChassisREF.NO. Part no Description Remark Picture Tube Packing Materials Memo List REF.NO. Part NO. Description Remark REF.NO. Part noREF.NO Description Remark Part NO. Description Remark REF.NO Description REF.NO DescriptionCoil REF.NO Part NO. Description RemarkIC Link ResistorREF.NO Part NO. Description GAP, Spark Spark GAPSocket SOCKET, Picture TubePIN, Connector PC Board 3P PIN, Connector with PWBPLUG, Connector 12P PLUG, Connector 5PREF.NO Description Remark Replace only with part number specified Screw +BVTP 3X10 TYPE2 TTB Spring AA, TR RetainerMetal Relay2KV PIN, Connector PC Board 6P PLUG, Connector 9PPIN, Connector PC Board 10P PLUG, Connector 2PCOIL, Horizontal Linearity Diode MA111Diode 1SS184 Zener Diode DTZ5.1BR063 216-025-91 RES,CHIP 100 10W R001 REF.NO Part NO. Description Switch TRANSFORMER, Ferrite HDTTRANSFORMER, Ferrite HST SWITCH, Stick Cont +/-, BRT + Crystal Thermistor Metal Thermistor SwitchDiode SLR-325YCT31 Connector Transistor PIN, Connector PC Board 12PSwitch Connector SWITCH, Push AC PowerSensor US BOARD, Complete NEW US BOARD, Complete OLDCeramic Chip 0.1 F Ceramic Chip 0.01 FFB2913 Short C2916 10% 25V FB2914 NEW OLD OLD Transformer 978-620-12 English