SECTION 5
CIRCUIT ADJUSTMENTS
ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER
Use the Remote Commander
NOTE: Test Equipment Required:
•Pattern generator
•Frequency counter
•Digital multimeter
•Audio oscillator
5-1. SETTING THE SERVICE ADJUSTMENT MODE
1. Standby mode (power off).
2. | Display |
|
| Channel 5 |
| Sound volume + |
| Power |
|
|
|
|
on the Remote Commander (press each button within a second).
Service Adjustment Mode On
1. The CRT displays the item being adjusted.
Disp. Item
(Item) Data
SERVICE HSIZ 0
2.Press or on the Remote Commander to select an item.
3.Press or on the Remote Commander to change the data.
4.Press then to save into the memory.
Service Adjustment Mode Memory
1.Press then on the Remote Commander to initialize.
SERVICE RESET
Carry out step 1 when adjusting IDs
5-2. MEMORY WRITE CONFIRMATION METHOD
1.After adjustment, remove the power plug from the AC outlet, then plug it in again.
2.Turn the power switch ON and set to service mode.
3.Call the adjusted items again to confirm they were adjusted.
5-3. ADJUSTMENT BUTTONS AND INDICATORS
MUTING | POWER |
DISPLAY
| 3 |
1 | 5 |
| |
| 6 |
4 |
|
8 | ENTER |
|
VOLUME
2. Turn set off then on to exit service adjustment mode.