SECTION 5
CIRCUIT ADJUSTMENTS
ELECTRICAL ADJUSTMENT BY REMOTE COMMANDER
Use Remote Commander
NOTE : Test Equipment Required:
1.Pattern Generator
2.Frequency Counter
3.Digital Multimeter
4.Audio OSC
(1)Method of Setting the Service Adjustment Mode
SERVICE MODE PROCEDURE
1.Standby mode. (Power off)
2. on the Remote Commander.
(Press each button within a second.)
SERVICE ADJUSTMENT MODE IN
Disp. Item
(Item) data
SERVICE | AFC 0 |
3.The CRT displays the item being adjusted.
4.Press or on the Remote Commander to select the item.
5.Press or on the Remote Commander to change the data.
6.Press then to write into memory**.
SERVICE ADJUSTMENT MODE MEMORY
SERVICE | RESET |
| Green |
Red
7.Press then on the Remote Commander to initialize.
SERVICE | WRITE | Carry out step 7 when adjusting |
|
| IDs 0 to 4 and when replacing |
|
| and adjusting IC002. |
8.Turn set off and on to exit. * CAUTION: Wait at least 10 seconds before turning off set.
(2)Memory Write Confirmation Method
1.After adjustment, pull out the plug from the AC outlet, then replace the plug in the AC outlet again.
2.Turn the power switch ON and set to Service Mode.
3.Call the adjusted items again to confirm they were adjusted.
(3)Adjust Buttons and Indicator
RM-Y167
**WARNING: Do NOT turn off the power or AC immediately after pressing then . Wait at least 10 seconds.
— 16 —