TABLE OF CONTENTS
Section |
| Title | Page | ||||
|
|
|
|
|
|
| |
1. | GENERAL |
|
| ||||
| Connecting and Installing the TV | 5 |
| ||||
| Operating Video Equipment | 7 |
| ||||
| Operating a Cable Box or DBS Receiver | 8 |
| ||||
| Troubleshooting | 8 |
| ||||
2. | DISASSEMBLY |
|
| ||||
| 9 |
| |||||
| 10 | ||||||
| 10 | ||||||
| 10 | ||||||
| Picture Tube Removal (32"/34") | 11 | |||||
| Picture Tube Removal (35"/37") | 11 | |||||
3. |
|
| |||||
| 12 | ||||||
| 13 | ||||||
| 14 | ||||||
| 14 | ||||||
| 14 | ||||||
4. | SAFETY RELATED ADJUSTMENTS | 15 | |||||
5. | CIRCUIT ADJUSTMENTS | 16 | |||||
6. | DIAGRAMS |
|
| ||||
| 23 | ||||||
| 27 | ||||||
| 34 | ||||||
| 34 |
Section | Title | Page |
• | A Board | 35 |
• | AV Board | 48 |
• | B Board | 48 |
• | C Board | 51 |
• | G Board | 52 |
• | HV Board | 55 |
• | HS Board | 55 |
• | K Board | 56 |
• | P Board | 57 |
• | WB Board | 58 |
• | UV Board | 59 |
• | WA Board | 63 |
65 | ||
7. EXPLODED VlEWS |
| |
66 | ||
| ||
67 | ||
|
| |
68 | ||
|
| |
| 35V65/37VL65/37VL65C) |
|
69 | ||
|
| |
70 | ||
|
| |
8. ELECTRICAL PARTS LIST |
| |
• Table of Contents for Parts List | 71 | |
• | Parts Listings | 72 |
WARNINGS AND CAUTIONS
CAUTION!
ATTENTION
AFTER REMOVING THE ANODE, SHORT CIRCUIT THE ANODE OF THE PICTURE TUBE AND THE ANODE CAP TO THE METAL CHASSIS, CRT SHIELD, OR CARBON PAINTED ON THE CRT.
APRES AVOIR DECONNECTE LE CAP DE L'ANODE,
WARNING!! | ATTENTION!! |
|
AN ISOLATION TRANSFORMER SHOULD BE USED DURING ANY SERVICE TO AVOID POSSIBLE SHOCK HAZARD, BECAUSE OF LIVE CHASSIS.THE CHASSIS OF THIS RECEIVER IS DIRECTLY CONNECTED TO THE AC POWER LINE.
COMPONENTS IDENTIFIED BY SHADING AND MARK Á ON THE SCHEMATIC DIAGRAMS, EXPLODED VIEWS AND IN THE PARTS LIST ARE CRITICAL FOR SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY. CIRCUIT ADJUSTMENTS THAT ARE CRITICAL FOR SAFE OPERATION ARE IDENTIFIED IN THIS MANUAL. FOLLOW THESE PROCEDURES WHENEVER CRITICAL COMPONENTS ARE REPLACED OR IMPROPER OPERATION IS SUSPECTED.
AFIN D'EVITER TOUT RESQUE D'ELECTROCUTION PROVENANT D'UN CHÁSSIS SOUS TENSION, UN TRANSFORMATEUR D'ISOLEMENT DOIT ETRE UTILISÉ LORS DE TOUT DÉPANNAGE. LE CHÁSSIS DE CE RÉCEPTEUR EST DIRECTEMENT RACCORDÉ À L'ALIMENTATION SECTEUR.
ATTENTION AUX COMPOSANTS RELATIFS A LA SECURITE!!
LES COMPOSANTS IDENTIFIES PAR UNE TRAME ET PAR UNE MARQUE Á SUR LES SCHEMAS DE PRINCIPE, LES VUES EXPLOSEES ET LES LISTES DE PIECES SONT D'UNEIMPORTANCE CRITIQUE POUR LA SECURITE DU FONCTIONNEMENT. NE LES REMPLACER QUE PAR DES COMPOSANTS SONY DONT LE NUMERO DE PIECE EST INDIQUE DANS LE PRESENT MANUEL OU DANS DES SUPPLEMENTS PUBLIES PAR SONY. LES REGLAGES DE CIRCUIT DONT L'IMPORTANCE EST CRI- TIQUE POUR LA SECURITE DU FONCTIONNEMENT SONT IDENTIFIES DANS LE PRESENT MANUEL. SUIVRE CES PROCEDURES LORS DE CHAQUE REMPLACEMENT DE COMPOSANTS CRITIQUES, OU LORSQU'UN MAUVAIS
FONTIONNEMENT SUSPECTE.
— 3 —