Sony KV-27V40 service manual Safety CHECK-OUT, Leakage Test

Page 7

KV-27S40 / 27S45 / 27S65 / 29SL40 / 29SL40A / 29SL40C/ 29SL45 / 29SL65 / 29SL65C/ 29XL40M / 29XL40P / 29XT11A

SAFETY CHECK-OUT

After correcting the original service problem, perform the following safety checks before releasing the set to the customer:

1.Check the area of your repair for unsoldered or poorly- soldered connections. Check the entire board surface for solder splashes and bridges.

2.Check the interboard wiring to ensure that no wires are “pinched” or contact high-wattage resistors.

3.Check that all control knobs, shields, covers, ground straps, and mounting hardware have been replaced. Be absolutely certain that you have replaced all the insulators.

4.Look for unauthorized replacement parts, particularly transistors, that were installed during a previous repair. Point them out to the customer and recommend their replacement.

5.Look for parts which, though functioning, show obvious signs of deterioration. Point them out to the customer and recommend their replacement.

6.Check the line cords for cracks and abrasion. Recommend the replacement of any such line cord to the customer.

7.Check the B+ and HV to see if they are specified values. Make sure your instruments are accurate; be suspicious of your HV meter if sets always have low HV.

8.Check the antenna terminals, metal trim, “metallized" knobs, screws, and all other exposed metal parts for AC Leakage. Check leakage as described below.

LEAKAGE TEST

The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microampere). Leakage current can be measured by any one of three methods.

1.A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers' instructions to use these instructions.

2.A battery-operated AC milliammeter. The Data Precision

245 digital multimeter is suitable for this job.

3.Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The "limit" indication is 0.75 V, so analog meters must have an accurate low voltage scale. The Simpson's 250 and Sanwa SH-63Trd are examples of passive VOMs that are suitable. Nearly all battery operated digital multimeters that have a 2V AC range are suitable. (See Fig. A)

HOW TO FIND A GOOD EARTH GROUND

A cold-water pipe is guaranteed earth ground; the cover-plate retaining screw on most AC outlet boxes is also at earth ground. If the retaining screw is to be used as your earth-ground, verify that it is at ground by measuring the resistance between it and a cold-water pipe with an ohmmeter. The reading should be zero ohms. If a cold-water pipe is not accessible, connect a 60-l00 watts trouble light (not a neon lamp) between the hot side of the re- ceptacle and the retaining screw. Try both slots, if necessary, to locate the hot side of the line, the lamp should light at normal brilliance if the screw is at ground potential. (See Fig. B)

To Exposed Metal Parts on Set

0.15 µF

AC

1.5 k ΩVoltmeter

(0.75 V)

Earth Ground

Fig. A. Using an AC voltmeter to check AC leakage.

7

Image 7
Contents Trinitron Color TV KV-27V65 SpecificationsTable of Contents SAFETY-RELATED Component Warning SELF-DIAGNOSTIC FunctionDisplay of STANDBY/TIMER Light Flash Count SELF-DIAGNOSTIC Circuit Leakage Test Safety CHECK-OUTAntenna Connecting directly to cable or anSection General Cable or Antenna Connections CVCR Connections Cable Box ConnectionsDBS Connections Connecting a DBS Direct Broadcast Satellite receiverAdditional Connections On-Screen Help/Instructions Using the remote control, Move & Select buttonsSetting up the TV automatically Inserting batteriesWatching the TV Using the White Labeled Buttons for TV OperationsTip z Watching two programs at one time PIPTo select the Video menu Using the Video menuTo restore the factory Video settings Learning menu selectionTo restore the factory Audio settings Using the Audio menuTo select the Audio menu To cancel the ON/OFF Timer function Using the Timer menuUsing the SET UP menu To select the Timer menuPress Reset while the SET UP menu is displayed To erase the Channel Block settingsDVD Digital Versatile Disc manufacturer code numbers Programming the remoteVCR manufacturer code numbers MDP Multi Disc Player manufacturer code numbersManufacturer code numbers DBS receiver If the remote control doesn’t workFor more details on operating the cable box or DBS receiver Manufacturer code numbers cable boxTroubleshooting Section Picture Tube Removal Beam Landing Section SET-UP AdjustmentsConvergence Method of Setting the Service Adjustment Mode Preparation before Confirmation Section Safety Related AdjustmentsFBT BoardElectrical Adjustment by Remote Commander Section Circuit AdjustmentsItem of Adjustments Fifr Field Frequency Sbal SUB Balance Disp OSD Position ID-0 ID-1 ID-2 ID-3 ID-4 ID-5 ID-6 ID-7 OUT Nted by Camcad Ba43blk Page Page Page Page Page Page Circuit Boards Location ONE Tuner Chassis KV-27V40/27V45/29VL40/29VL85 Section Exploded ViewsTWO Tuner Chassis KV-27V65/29VL65A/29VL65C/29VL95 Main Power Switch KV-29VL65A only Model BOARD, Complete Section Electrical Parts ListCapacitor Acommon Parts Listing Diode FilterCoil Ferrite BeadJack Chip ConductorResistor TransistorRES, Chip R277 Short R278 Metal Thermistor SwitchRelay TransformerKV-27V40/29VL40 Connector56K Board Variant List KV-27V65/29VL95 KV-27V65/29VL95THP601 1-809-539-11 Thermistor Positive KV-29VL65A KV-27V45/29VL85 REF.NO. Part no Description KV-29VL65C Cemented CV BOARD, Complete Fuse CV EHV BOARD, Complete Complete Parts ListingHZ BOARD, Complete KV-29VL65A only HV HZComplete Parts Listing K Pcomplete Parts Listing Crystal Complete Parts Listing PRemote Commander Accessories and Packing MaterialsSony Corporation