Panasonic TH-PH10 manual PC Input Terminals connection, Connections

Page 10

Connections

PC Input Terminals connection

COMPUTER

Conversion adapter (if necessary)

(Example: TH-42PH10UK)

AUDIO

PC IN

Mini D-sub 15p

RGB

PC cable

Audio

Stereo plug

Connect a cable which matches

the audio output terminal on the computer.

Notes:

Due to space limitations, occasionally you may have trouble connecting Mini D-sub 15P cable with ferrite core to PC input Terminal.

Computer signals which can be input are those with a horizontal scanning frequency of 15 to 110 kHz and vertical scanning frequency of 48 to 120 Hz. (However, the image will not be displayed properly if the signals exceed 1,200 lines.)

The display resolution is a maximum of 768 × 720 dots (TH-37PH10UK), 768 × 768 dots (TH-42PH10UK), 1,024 × 768 dots (TH-50PH10UK, TH-58PH10UK) when the aspect mode is set to “NORMAL”, and 1,024 × 720 dots (TH-37PH10UK), 1,024 × 768 dots (TH-42PH10UK), 1,366 × 768 dots (TH-50PH10UK, TH-58PH10UK) when the aspect mode is set to “FULL”. If the display resolution exceeds these maximums, it may not be possible to show fine detail with sufficient clarity.

The PC input terminals are DDC2B-compatible. If the computer being connected is not DDC2B-compatible, you will need to make setting changes to the computer at the time of connection.

Some PC models cannot be connected to the set.

There is no need to use an adapter for computers with DOS/V compatible Mini D-sub 15P terminal.

The computer shown in the illustration is for example purposes only.

Additional equipment and cables shown are not supplied with this set.

Do not set the horizontal and vertical scanning frequencies for PC signals which are above or below the specified frequency range.

Component Input is possible with the pin 1, 2, 3 of the D-sub 15P Connector.

Change the “COMPONENT/RGB-IN SELECT” setting in the “SET UP” menu to “COMPONENT” (when component connection) or “RGB” (when RGB signal connection). (see page 36)

Signal Names for Mini D-sub 15P Connector

TH-37PH10UK

11

12

13

 

14

15

6

7

8

9

10

1 2 3 4 5

TH-42PH10UK, TH-50PH10UK,

TH-58PH10UK

5

 

4

3

2

 

1

10

9

 

8

7

6

15

14

13

12

 

11

Pin No.

Signal Name

Pin No.

Signal Name

Pin No.

Signal Name

1

R (PR/CR)

6

GND (Ground)

11

NC (not connected)

2

G (Y)

7

GND (Ground)

12

SDA

3

B (PB/CB)

8

GND (Ground)

13

HD/SYNC

4

NC (not connected)

9

NC (not connected)

14

VD

5

GND (Ground)

10

GND (Ground)

15

SCL

Pin Layout for PC Input Terminal

10

Image 10
Contents English Español Operating Instructions Manual de instruccionesModel No. Número de modelo Risk of Electric Shock Do not Open Important Safety Instructions Table of Contents FCC Statement Trademark CreditsSafety Precautions When using the Plasma Display Setup Maintenance Safety Precautions / Maintenance AC Power Supply CordAccessories Supplied AccessoriesRemote Control Batteries Speakers ConnectionsAC cord fixing PC Input Terminals connection Signal Names for Mini D-sub 15P ConnectorConnections Communication parameters CommandSerial Terminals connection Basic format for control dataRGB signal R, G, B AV & Component / RGB connectionConnecting the plug to the Wall Outlet Power on / OFFConnecting the AC cord plug to the Plasma Display Fix the AC cord plug securely to the Plasma Display. seeBasic Controls Basic Controls VA N C E D Settings On-Screen Menu DisplaysOn Time / Power OFF Time / Power OFF TimeOn-Screen Menu Displays Selecting the On-Screen Menu Language Selecting the input signalInitial selections INPUT1A INPUT1B INPUT2 PCPanasonic Auto Aspect ControlsNormal Zoom Full During Multi PIP OperationsRGB/PC in mode Adjusting POS. /SIZEClock Phase Eliminate the flickering and distortionMulti PIP Sub screen Main screen Advanced PIPOne screen Advanced PIP Press to exit from Options menu 1280x768@60Hz DVIAdvanced Settings OFF Picture AdjustmentsAdvanced Settings on Standard Cinema DynamicEffect Adjustments Advanced SettingsPicture Adjustments Effect DetailsSound Adjustment MutePosition Digital ZoomDisplay the operation guide Select the magnification required for the enlarged displayPress to set up DAY or Present Time of DAY Present Time SetupButton Forward Display the SET UP Timer Screen Press to select SET UP TimerPower on Time / Power OFF Time Screensaver For preventing image retention Mode selectionStart setting Negative / Scroll selectionReduces screen image retention Setup of Screensaver TimeScreensaver For preventing image retention OFF Dark MID Bright Side BAR AdjustPress to exit from Screensaver Customizing the Input labels Reduces power consumptionAddition sign Selected Input Press to select Vertical Scale SET UP for Multi DisplayHow to setup Multi Display Press to select × 1, × 2, × 3, ×SET UP for Multi Display Display Number locations for each arrangement ExamplesID remote control button operation Seam Hides Video SettingID Remote Control Function ID Cancellation3D Y/C Filter For Ntsc AV images SET UP for Input SignalsComponent / RGB in Select SelectColor System / Panasonic Auto SET UP for Input SignalsPulldown / Video NR Refresh Rate Setting RGB sync signalSync FREQ. kHz / V-FREQ. HzOptions Adjustments Options1/3Options Adjustments Off Initial VOL Sets normal volume LevelEnable Normalization Weekly Command Timer Time Set the time to execute a command program Press to select a command numberPress to select Time / Command Press to set each itemShipping condition Troubleshooting Plasma Display panelPAL60 VIDEO/COMPONENT/RGB/PC input signalsVideo input RGBCommand list of Weekly Command Timer Specifications TH-37PH10UK TH-42PH10UKSpecifications TH-50PH10UK TH-58PH10UKLimits and Exclusions Limited Warranty Statement Executive Office Customer’s RecordPanasonic Broadcast & Television Systems Company Panasonic Canada Inc