Panasonic TH-PH10 manual Options Adjustments, Off Initial VOL Sets normal volume Level

Page 40

Options Adjustments

Options1/3

Weekly Command Timer

Onscreen display

 

On

 

 

 

 

 

Initial INPUT

 

Off

 

Initial VOL level

Off

0

 

Maximum VOL level

Off

0

 

INPUT lock

 

Off

 

Button lock

 

Off

 

Remocon User level

 

Off

 

Advanced PIP

 

Off

 

Item

Effect

Adjustments

Press button to adjust the volume when the unit is turned on.

 

 

Off

On

Initial VOL

 

Off:

Sets normal volume.

level

Off On

On:

Sets your preferred volume.

 

 

Notes:

 

When “Maximum VOL level” is “On”, the volume can only be adjusted between 0 and your maximum range.

You can hear the changed volume regardless of your volume setting before opening the options menu if you adjust the volume when “Initial VOL level” is “On” and cursor is on the menu.

 

 

 

Press

 

 

 

 

button to adjust the maximum volume.

 

 

 

 

 

 

 

 

 

Off

 

 

 

 

On

 

 

 

Off:

Sets auto maximum volume.

Maximum VOL

 

 

On:

Sets your preferred maximum volume.

level

Off

On

Notes:

 

 

 

 

 

 

 

 

• If the “Maximum VOL level” is set lower than the “Initial VOL level”, the “Initial VOL level” automatically

 

 

 

becomes the same as the “Maximum VOL level”.

 

 

 

• The volume display can go up to 63 regardless of the settings.

 

 

 

• You can hear the changed volume regardless of your volume setting before opening the options menu if you

 

 

 

adjust the volume when “Maximum VOL level” is “On” and cursor is on the menu.

Off PC INPUT1 INPUT2 INPUT3

Locks the input switch operation.

Notes:

Only the adjusted signal is displayed (see page 18).

Signal can be displayed when the Terminal board is installed.

INPUT lock

• Input switch can be used when this is set to “Off”.

In two screen display mode, if anything other than “Off” is set, the value will be fixed as the value input in the single screen display mode.

When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B)

Setting of SLOT3 is not available on TH-37PH10UK.

Off MENU&ENTER On

Off: All the buttons at the bottom of the main unit can be used.

MENU & ENTER: Locks and buttons on bottom face of main unit.

 

 

 

 

 

MENU

ENTER/

 

 

 

 

Button lock

On: Locks all the button on bottom face of main unit.

 

 

 

Sets Button lock with the unit buttons in the following procedure.

 

 

 

Off: Press

four times→Press

four times→Press

four times→Press

 

 

MENU & ENTER: Press

 

INPUT

four times→Press

ENTER/

 

 

four times→Press

four times→Press

 

 

On: Press

 

 

ENTER/

four times→Press

 

INPUT

ENTER/

 

four times→Press

four times→Press

 

 

 

 

 

 

 

ENTER/

 

 

ENTER/

 

 

Off

User1

User2

User3

 

 

 

 

 

Off:

You can use all of the buttons on the remote control.

 

 

Remocon

User1:You can only use

,

, ,

, ,

, ,

buttons on the remote control.

User level

User2:You can only use

,

, buttons on the remote control.

 

 

 

 

 

User3:Locks all the buttons on remote control.

 

Off:

 

Sets normal two screen display mode (see page 21).

 

On:

 

Sets Advanced PIP mode (see page 22).

Advanced PIP Off On

Notes:

 

• When “INPUT lock” is “On”, you cannot use all the two screen display functions.

 

,

buttons are unavailable during Advanced PIP mode operation.

40

Image 40
Contents English Español Operating Instructions Manual de instruccionesModel No. Número de modelo Risk of Electric Shock Do not Open Important Safety Instructions Table of Contents FCC Statement Trademark CreditsSafety Precautions When using the Plasma DisplayMaintenance Safety Precautions / MaintenanceSetup AC Power Supply CordAccessories Supplied AccessoriesRemote Control Batteries Speakers ConnectionsAC cord fixing PC Input Terminals connection Signal Names for Mini D-sub 15P ConnectorConnections Command Serial Terminals connectionCommunication parameters Basic format for control dataRGB signal R, G, B AV & Component / RGB connectionPower on / OFF Connecting the AC cord plug to the Plasma DisplayConnecting the plug to the Wall Outlet Fix the AC cord plug securely to the Plasma Display. seeBasic Controls Basic Controls VA N C E D Settings On-Screen Menu DisplaysOn Time / Power OFF Time / Power OFF TimeOn-Screen Menu Displays Selecting the input signal Initial selectionsSelecting the On-Screen Menu Language INPUT1A INPUT1B INPUT2 PCAspect Controls Normal Zoom FullPanasonic Auto During Multi PIP OperationsAdjusting POS. /SIZE Clock PhaseRGB/PC in mode Eliminate the flickering and distortionMulti PIP Advanced PIP One screen Advanced PIP Press to exit from Options menuSub screen Main screen 1280x768@60Hz DVIPicture Adjustments Advanced Settings onAdvanced Settings OFF Standard Cinema DynamicAdvanced Settings Picture AdjustmentsEffect Adjustments Effect DetailsSound Adjustment MuteDigital Zoom Display the operation guidePosition Select the magnification required for the enlarged displayPress to set up DAY or Present Time of DAY Present Time SetupButton Forward Display the SET UP Timer Screen Press to select SET UP TimerPower on Time / Power OFF Time Mode selection Start settingScreensaver For preventing image retention Negative / Scroll selectionReduces screen image retention Setup of Screensaver TimeScreensaver For preventing image retention OFF Dark MID Bright Side BAR AdjustPress to exit from Screensaver Customizing the Input labels Reduces power consumptionAddition sign Selected Input SET UP for Multi Display How to setup Multi DisplayPress to select Vertical Scale Press to select × 1, × 2, × 3, ×SET UP for Multi Display Display Number locations for each arrangement ExamplesSeam Hides Video Setting ID Remote Control FunctionID remote control button operation ID CancellationSET UP for Input Signals Component / RGB in Select3D Y/C Filter For Ntsc AV images Select Color System / Panasonic Auto SET UP for Input Signals Pulldown / Video NR Setting RGB sync signal SyncRefresh Rate FREQ. kHz / V-FREQ. HzOptions Adjustments Options1/3Options Adjustments Off Initial VOL Sets normal volume LevelEnable Normalization Weekly Command Timer Press to select a command number Press to select Time / CommandTime Set the time to execute a command program Press to set each itemShipping condition Troubleshooting Plasma Display panelVIDEO/COMPONENT/RGB/PC input signals Video inputPAL60 RGBCommand list of Weekly Command Timer Specifications TH-37PH10UK TH-42PH10UKSpecifications TH-50PH10UK TH-58PH10UKLimits and Exclusions Limited Warranty Statement Customer’s Record Panasonic Broadcast & Television Systems CompanyExecutive Office Panasonic Canada Inc