Panasonic TH-50PF11UK, TH-65PF11UK, TH-58PF11UK manual PC Input Terminals connection, Connections

Page 10
Connections

Connections

PC Input Terminals connection

COMPUTER

Conversion adapter (if necessary)

(Female)

AUDIO

PC IN

Mini D-sub 15p

RGB

PC cable

(Male)

Audio

Stereo plug

Connect a cable which matches

the audio output terminal on the computer.

Notes:

Due to space limitations, occasionally you may have trouble connecting Mini D-sub 15P cable with ferrite core to PC input Terminal.

With regard to the typical PC input signals that are described in the applicable input signals list (see page 51), adjustment values such as for the standard picture positions and sizes have already been stored in this unit. You can add up to eight PC input signal types that are not included in the list.

Computer signals which can be input are those with a horizontal scanning frequency of 15 to 110 kHz and vertical scanning frequency of 48 to 120 Hz. (However, the image will not be displayed properly if the signals exceed 1,200 lines.)

The display resolution is a maximum of 1,440 × 1,080 dots when the aspect mode is set to “4:3”, and 1,920 × 1,080 dots when the aspect mode is set to “FULL”. If the display resolution exceeds these maximums, it may not be possible to show fine detail with sufficient clarity.

The PC input terminals are DDC2B-compatible. If the computer being connected is not DDC2B-compatible, you will need to make setting changes to the computer at the time of connection.

Some PC models cannot be connected to the set.

There is no need to use an adapter for computers with DOS/V compatible Mini D-sub 15P terminal.

The computer shown in the illustration is for example purposes only.

Additional equipment and cables shown are not supplied with this set.

Do not set the horizontal and vertical scanning frequencies for PC signals which are above or below the specified frequency range.

Component Input is possible with the pin 1, 2, 3 of the Mini D-sub 15P Connector.

Change the “COMPONENT/RGB-IN SELECT” setting in the “SET UP” menu to “COMPONENT” (when COMPONENT signal connection) or “RGB” (when RGB signal connection). (see page 39)

Signal Names for Mini D-sub 15P Connector

5 4 3 2 1

10

9

 

8

7

6

15

14

 

13

12

 

11

Pin Layout for PC Input Terminal

Pin No.

Signal Name

Pin No.

Signal Name

Pin No.

Signal Name

1

R (PR/CR)

6

GND (Ground)

11

NC (not connected)

2

G (Y)

7

GND (Ground)

12

SDA

3

B (PB/CB)

8

GND (Ground)

13

HD/SYNC

4

NC (not connected)

9

+5 V DC

14

VD

5

GND (Ground)

10

GND (Ground)

15

SCL

10

Image 10
Contents English Español High Definition Plasma Display Alta definición Pantalla de plasmaOperating Instructions Manual de instrucciones TH-42PF11UK TH-50PF11UK TH-58PF11UK TH-65PF11UKRISK OF ELECTRIC SHOCK DO NOT OPEN Important Safety Instructions Table of Contents Dear Panasonic CustomerCANADIAN NOTICE FCC STATEMENTFCC CAUTION Trademark CreditsClean the power cable regularly to prevent it from becoming dusty Safety PrecautionsWhen using the Plasma Display Be sure to disconnect all cables before moving the Plasma DisplaySetup MaintenanceSafety Precautions / Maintenance AC Power Supply CordRemote Control Batteries AccessoriesAccessories Supplied Check that you have the Accessories and items shownAC cord fixing ConnectionsCable fixing band Connections PC Input Terminals connectionSignal Names for Mini D-sub 15P Connector Command SERIAL Terminals connectionSignal names for D-sub 9P connector Communication parametersCOMPONENT / RGB connection HDMI connectionSLOT2 Connecting the AC cord plug to the Plasma Display Power ON / OFFConnecting the plug to the Wall Outlet PRESENT TIME SETUP Power ON / OFFWhen first switching on the unit OSD LANGUAGEInitial selections Selecting the input signalSelecting the On-Screen Menu Language Remote control sensor Basic ControlsMain Unit Volume AdjustmentSET UP button see page SOUND button see page DIRECT INPUT buttons Remote Control TransmitterBasic Controls Channel AdjustmentPanasonic AUTO ASPECT ControlsAll Aspect mode ASPECT Controls MULTI PIP SETUPMULTI PIP Selecting the Display ModeDuring Blend PIP Composite Screen Function MULTI PIPSwapping Screens Transparent Function and Insertion FunctionOperations on Selecting the Target Screen for OperationsSelecting the Sub Screen Position During P IN P Display the main screenDuring Digital Zoom, only the following buttons can be operated Digital Zoom1 Display the operation guide Select the area of the image to be enlargedSelect the item Remote Control Display the menu screenOn-Screen Menu Display UnitAdjust the vertical position Adjusting POS. /SIZEAdjust the horizontal position Adjust the horizontal sizeNormalization Adjusting POS. /SIZEHelpful Hint NORMALIZEDYNAMIC PICTURE AdjustmentsSTANDARD CINEMAAdjustments ADVANCED SETTINGSPICTURE Adjustments EffectSOUND Adjustment SDI SOUND OUTPUTSET UP TIMER PRESENT TIME SETUP / SET UP TIMERPRESENT TIME SETUP Press to select POWER ON TIME / POWER OFF TIMESCREENSAVER For preventing image retention Setup of SCREENSAVER Time5 START setting FUNCTION selectionReduces screen image retention SIDE BAR ADJUSTSCREENSAVER For preventing image retention POWER SAVE Reduces power consumptionSIGNAL AUTO POWER OFFAddition sign Customizing the Input labelsDISPLAY ORIENTATION Selected InputDisplay Number locations for each arrangement SET UP for MULTI DISPLAYHow to setup MULTI DISPLAY ExamplesID remote control button operation ID Remote Control FunctionSET UP for MULTI DISPLAY ID CancellationDISPLAY MODE MULTI PIP SETUPMULTI PIP Transparent Display of the Sub Screen During BLEND PIPSET UP for PORTRAIT How to setup PORTRAITLOCATION setting SET UP for PORTRAIT6 AI-SYNCHRONIZATION When PORTRAIT SETUP “ON”COMPONENT / RGB IN SELECT SET UP for Input SignalsYUV / RGB IN SELECT 3D Y/C FILTER - For NTSC AV images SIGNAL menuSET UP for Input Signals Press to exit from adjust modeXGA MODE COLOR SYSTEM / Panasonic AUTO32 PULLDOWN If the image becomes unstableNOISE REDUCTION REFRESH RATEAdvanced NR Displays the frequency and the type of the current input signal Input signal displaySetting RGB sync signal SYNCPress to display the Setup menu Press to select “OSD Language” Options AdjustmentsPress to adjust the menu Press to exit from Options menu Options Adjustments User2Press the button on the remote control and hold for more than 5 seconds. TheNormalization button on main unit together withWeekly Command Timer Shipping condition SHIPPINGPicture TroubleshootingPlasma Display panel SoundIn the case of SD signals, pictures with a 43 aspect ratio are List of Aspect Modesenlarged horizontally, and displayed. This mode is suited to TY-FB11DHD is installed Applicable Input Signals∗4 The input signal is recognized as 1,125 1,080 / 60p Note Signals without above specification may not be displayed properlyApplicable Input Signals VIDEO input HDMICommand list of Weekly Command Timer Specifications Specifications In the USA and Puerto Rico FOR SERVICE CALL TOLL FREE for the U.S.A and Puerto RicoPanasonic Professional Flat Panel Display Limited Warranty WarrantyWARRANTY COVERAGE PERIOD EXCEPTIONS LIMITED WARRANTY STATEMENTfor Canada Warranty ServicePage Page Executive Office Customer’s RecordPanasonic Professional Display Company Panasonic Canada Inc