Panasonic TH-42PF11UK SERIAL Terminals connection, Connections, Communication parameters, Command

Page 11
SERIAL Terminals connection

Connections

SERIAL Terminals connection

The SERIAL terminal is used when the Plasma Display is controlled by a computer.

COMPUTER

(Male)

1 2 3 4 5

6 7 8 9

RS-232C Straight cable

SERIAL

Pin layout for SERIAL Terminal

(Female)

D-sub 9p

Notes:

Use the RS-232C straight cable to connect the computer to the Plasma Display.

The computer shown is for example purposes only.

Additional equipment and cables shown are not supplied with this set.

The SERIAL terminal conforms to the RS-232C interface specification, so that the Plasma Display can be controlled by a computer which is connected to this terminal.

The computer will require software which allows the sending and receiving of control data which satisfies the conditions given below. Use a computer application such as programming language software. Refer to the documentation for the computer application for details.

Signal names for D-sub 9P connector

Pin No.

Details

 

2

R X D

 

3

T X D

 

5

GND

4

6

Non use

 

7

(Shorted in this set)

 

8

 

 

1

9

NC

These signal names are those of computer specifications.

Communication parameters

Signal level

RS-232C compliant

Synchronization method

Asynchronous

Baud rate

9600 bps

Parity

None

Character length

8 bits

Stop bit

1 bit

Flow control

-

Basic format for control data

The transmission of control data from the computer starts with a STX signal, followed by the command, the parameters, and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent.

STX Signal names for D-sub 9P connectorCommunication parametersC1 C2 C3 Basic format for control dataCommand : Manual backgroundManual backgroundP1 P2 P3 P4 P5 Manual backgroundManual background ETX

 

Colon

Parameter(s)

End

Start

3-character

(1 - 5 bytes)

(03h)

(02h)

command (3 bytes)

 

 

Notes:

If multiple commands are transmitted, be sure to wait for the response for the first command to come from this unit before sending the next command.

If an incorrect command is sent by mistake, this unit will send an “ER401” command back to the computer.

SL1A, SL1B, SL2Aand SL2B of Command IMS are available only when a dual input terminal board is attached.

Command

Command

Parameter

Control details

PON

None

Power ON

POF

None

Power OFF

AVL

**

Volume 00 - 63

AMT

0

Audio MUTE OFF

 

1

Audio MUTE ON

IMS

None

Input select (toggle)

 

SL1

Slot1 input

 

SL2

Slot2 input

 

SL3

Slot3 input

 

PC1

PC input

 

SL1A

Slot1 input (INPUT1A)

 

SL1B

Slot1 input (INPUT1B)

 

SL2A

Slot2 input (INPUT2A)

 

SL2B

Slot2 input (INPUT2B)

DAM

None

Screen mode select (toggle)

 

ZOOM

ZOOM

 

FULL

FULL

 

JUST

JUST

 

NORM

4:3

 

SELF

Panasonic Auto

 

SJST

JUST

 

SNOM

4:3

 

SFUL

H-FILL

With the power off, this display responds to PON command only.

11

Image 11
Contents TH-42PF11UK TH-50PF11UK TH-58PF11UK TH-65PF11UK High Definition Plasma Display Alta definición Pantalla de plasmaOperating Instructions Manual de instrucciones English EspañolRISK OF ELECTRIC SHOCK DO NOT OPEN Important Safety Instructions Dear Panasonic Customer Table of ContentsTrademark Credits FCC STATEMENTFCC CAUTION CANADIAN NOTICEBe sure to disconnect all cables before moving the Plasma Display Safety PrecautionsWhen using the Plasma Display Clean the power cable regularly to prevent it from becoming dustyAC Power Supply Cord MaintenanceSafety Precautions / Maintenance SetupCheck that you have the Accessories and items shown AccessoriesAccessories Supplied Remote Control BatteriesCable fixing band ConnectionsAC cord fixing Signal Names for Mini D-sub 15P Connector PC Input Terminals connectionConnections Communication parameters SERIAL Terminals connectionSignal names for D-sub 9P connector CommandSLOT2 HDMI connectionCOMPONENT / RGB connection Connecting the plug to the Wall Outlet Power ON / OFFConnecting the AC cord plug to the Plasma Display OSD LANGUAGE Power ON / OFFWhen first switching on the unit PRESENT TIME SETUPSelecting the On-Screen Menu Language Selecting the input signalInitial selections Volume Adjustment Basic ControlsMain Unit Remote control sensorChannel Adjustment Remote Control TransmitterBasic Controls SET UP button see page SOUND button see page DIRECT INPUT buttonsAll Aspect mode ASPECT ControlsPanasonic AUTO Selecting the Display Mode MULTI PIP SETUPMULTI PIP ASPECT ControlsTransparent Function and Insertion Function MULTI PIPSwapping Screens During Blend PIP Composite Screen Functionthe main screen Selecting the Target Screen for OperationsSelecting the Sub Screen Position During P IN P Display Operations onSelect the area of the image to be enlarged Digital Zoom1 Display the operation guide During Digital Zoom, only the following buttons can be operatedUnit Remote Control Display the menu screenOn-Screen Menu Display Select the itemAdjust the horizontal size Adjusting POS. /SIZEAdjust the horizontal position Adjust the vertical positionNORMALIZE Adjusting POS. /SIZEHelpful Hint NormalizationCINEMA PICTURE AdjustmentsSTANDARD DYNAMICEffect ADVANCED SETTINGSPICTURE Adjustments AdjustmentsSDI SOUND OUTPUT SOUND AdjustmentPress to select POWER ON TIME / POWER OFF TIME PRESENT TIME SETUP / SET UP TIMERPRESENT TIME SETUP SET UP TIMERFUNCTION selection Setup of SCREENSAVER Time5 START setting SCREENSAVER For preventing image retentionSCREENSAVER For preventing image retention SIDE BAR ADJUSTReduces screen image retention AUTO POWER OFF Reduces power consumptionSIGNAL POWER SAVESelected Input Customizing the Input labelsDISPLAY ORIENTATION Addition signExamples SET UP for MULTI DISPLAYHow to setup MULTI DISPLAY Display Number locations for each arrangementID Cancellation ID Remote Control FunctionSET UP for MULTI DISPLAY ID remote control button operationTransparent Display of the Sub Screen During BLEND PIP MULTI PIP SETUPMULTI PIP DISPLAY MODEHow to setup PORTRAIT SET UP for PORTRAITWhen PORTRAIT SETUP “ON” SET UP for PORTRAIT6 AI-SYNCHRONIZATION LOCATION settingYUV / RGB IN SELECT SET UP for Input SignalsCOMPONENT / RGB IN SELECT Press to exit from adjust mode SIGNAL menuSET UP for Input Signals 3D Y/C FILTER - For NTSC AV imagesIf the image becomes unstable COLOR SYSTEM / Panasonic AUTO32 PULLDOWN XGA MODEAdvanced NR REFRESH RATENOISE REDUCTION SYNC Input signal displaySetting RGB sync signal Displays the frequency and the type of the current input signalPress to adjust the menu Press to exit from Options menu Options AdjustmentsPress to display the Setup menu Press to select “OSD Language” User2 Options Adjustmentsbutton on main unit together with button on the remote control and hold for more than 5 seconds. TheNormalization Press theWeekly Command Timer SHIPPING Shipping conditionSound TroubleshootingPlasma Display panel Pictureenlarged horizontally, and displayed. This mode is suited to List of Aspect ModesIn the case of SD signals, pictures with a 43 aspect ratio are Note Signals without above specification may not be displayed properly Applicable Input Signals∗4 The input signal is recognized as 1,125 1,080 / 60p TY-FB11DHD is installedVIDEO input HDMI Applicable Input SignalsCommand list of Weekly Command Timer Specifications Specifications Warranty for the U.S.A and Puerto RicoPanasonic Professional Flat Panel Display Limited Warranty In the USA and Puerto Rico FOR SERVICE CALL TOLL FREEWarranty Service LIMITED WARRANTY STATEMENTfor Canada WARRANTY COVERAGE PERIOD EXCEPTIONSPage Page Panasonic Canada Inc Customer’s RecordPanasonic Professional Display Company Executive Office