Panasonic AJ-D950 manual Table of Auto OFF Error messages, Power OFF→ON, Eject, Power OFF on

Page 73

Table of AUTO OFF Error messages

Counter display

Monitor display

 

Description

VTR operation

 

(Restart condition)

 

 

 

 

 

 

 

 

CAP ROTATE TOO

CAP ROTA TOO

If the capstan motor speed is abnormally low, the

STOP

SLOW

SLOW

AUTO OFF lamp lights, and the message display

(POWER OFFON)

 

 

flashes.

 

CAP TENSION ERROR

CAP TENSION ERROR

If an abnormal tension at the supply side is detected

STOP

 

 

in the capstan mode, the AUTO OFF lamp lights, and

 

 

the message display flashes.

(POWER OFFON)

 

 

 

 

 

 

 

DEW

DEW

If condensation is detected, the AUTO OFF lamp

EJECT

 

 

lights, the message display flashes, and the VTR is

 

 

transferred to the eject mode. After the tape is

(Normal operation

 

 

ejected, the drum rotates in order to eliminate the

resumed after

 

 

condensation.

condensation is

 

 

When the condensation has been eliminated, the

eliminated)

 

 

AUTO OFF lamp and message display go off, and the

 

 

 

VTR can be used.

 

 

 

<Notes>

 

 

 

1)

If condensation is detected in the eject mode, the

 

 

 

2)

drum starts rotating as soon as it is detected.

 

 

 

If condensation is detected when the cassette has

 

 

 

 

been inserted, the drum rotation is stopped, and

 

 

 

 

after the tape is ejected, the drum starts rotating.

 

 

 

 

 

DRUM ROTATE TOO

DRUM ROTA TOO

If the cylinder motor speed is abnormally high, the

STOP

FAST

FAST

AUTO OFF lamp lights, and the message display

(POWER OFFON)

 

 

flashes.

 

DRUM ROTATE TOO

DRUM ROTA TOO

If the cylinder motor speed is abnormally low, the

STOP

SLOW

SLOW

AUTO OFF lamp lights, and the message display

(POWER OFFON)

 

 

flashes.

 

E-FF

E-FF

If the tape start and tape end are detected simulta-

STOP

 

neously either during or after loading, the AUTO OFF

 

 

lamp lights, and the message display flashes.

(POWER OFF ON)

 

 

 

 

 

 

 

FRONT LOAD ERROR

FRONT LOAD ERROR

The AUTO OFF lamp lights and the message display

 

 

 

flashes when the take-up reel has been rotating idly

STOP

 

 

for a fixed period of time while the start/end

(POWER OFFON)

 

 

processing operation during loading (half position) is

 

 

 

being performed.

 

 

 

 

 

FRONT LOAD MOTOR

FRONT LOAD MOTOR

If the cassette does not move up even when 6

 

 

 

seconds have elapsed since the VTR was transferred

 

 

 

to the eject mode, the AUTO OFF lamp lights, and the

 

 

 

message display flashes.

STOP

 

 

<Note>

 

 

(POWER OFFON)

 

 

If the cassette does not move down inside the

 

 

machine even when 6 seconds have elapsed since

 

 

 

the cassette was inserted, the VTR is transferred to

 

 

 

the eject mode.

 

 

 

 

 

LOADING MOTOR

LOADING MOTOR

When the unloading operation is not completed within

 

 

 

6 seconds, the AUTO OFF lamp lights, and the

 

 

 

message display flashes.

STOP

 

 

<Note>

 

 

(POWER OFFON)

 

 

When the loading operation is not completed within 6

 

 

seconds, the VTR is transferred to the eject (unload-

 

 

 

ing) mode.

 

 

 

 

 

 

– 74 –

Image 73
Contents Operating Instructions Contents Features General and FeaturesMultifunctional interface Menu-driven setupChannel high-sound-quality digital audio Front panel Controls and their functionsFront Panel Top Section Video Input Select switchesAudio Input Select displayFront Panel Center Section @0TC/UB switch 9TC/CTL switch@1INT/EXT switch @2TAPE/EE switch In the stop mode@7SHTL/SLOW switch @3REMOTE/LOCAL switch@4REMOTE lamp @5Search button#1AUTO Edit button #0PREROLL button#2PREVIEW/REVIEW buttons #3IN a IN/SET/OUT a OUT buttons#8Time code buttons $6Headphones jack#9Warning lamp $0Cassette insertion display lamp$8MONITOR Select switches $7Volume control$9METER FULL/FINE selector switch Front Panel Bottom Section 8TV System selector switch 7REC Inhibit switch9MENU button 0SET button@2 @3 Connector areaSignal GND terminal AC in connectorTime Code in connector Time Code OUT connector7ANALOG Composite Video OUT connectors 6ANALOG Component Video OUT connector8DIGITAL Audio IN/OUT connector 9SERIAL Digital Component AUDIO/VIDEO IN/OUT connectorSet the Control switch on the front panel to Local Connections when one unit is usedRecorder Device Connections when 2 units are used deck to deckConnections with editing controller Video monitor Signals Audio monitorWFM VSC Type Description TapesCassette Stand by Player Switching on the power/inserting the cassetteStill Timer Setting STOP/STAND by mode2Adjusting the video level 1Selecting video/audio input signals3Adjusting the audio level RecordingPlayback Shuttle mode Jog modeJog/shuttle Manual editing Preroll Automatic editing Deck to Deck When the unit is used as the recorder Switch settings and adjustmentsWhen the unit is used as the player Automatic editingSelect the editing mode Match frame processing function Entering the edit pointsNegative duration function Calculating the duration Checking the edit points2Resetting either the edit in or OUT point 1Resetting both the edit in and OUT pointsModifying the edit points Preview Postroll Executing automatic editingRetry function Auto tag editingReview Split editing Entering the edit points Audio split editingDeleting the edit points Modifying the edit pointsCueing up the tape to the edit points Displaying the audio split edit pointsDuration display OperationsSetup level Video output encoder output signal adjustmentsVideo level Chroma level and hueChanging the settings Setup default settingsSETUP-MENU Init SET YESPLAY/NOSTOP Changing the file Setup setting menusSystem menu Setting DescriptionUser menu Basic Setting Description Setup menusEE Mode AlarmDelay SearchMemory stop function OperationCAP.LOCK Auto REW9P SEL Para RUNID SEL OtherIN/OUT VARManu DELEdit Setting Description Step SRCProtect HalfTime Code Vsync INT SGLOW RF FreezeVideo Setting Description CH4 CH3CH1 OUT CH2 OUTAudio Setting Description AJ-PD950 User menu Time code Time code/user bitUser bit Recording internal/external time codes Setting the internal time codeReproducing the time code/user bit Superimpose screen Operation modeCharacters displayed Display positionServo reference During playback or special playback Servo reference setting tablesDuring recording or editing Audio V Fade Function Audio recording channel Audio recording channel and monitor output selectionMonitor output channel Printed Abbr Factory Circuit Full name Function Printed circuit boardBoard Rack mounting Condensation Video head cleaningDiag menu Error messagesDisplaying the Diag menu Displaying the Hours Meter information Power OFF→ON Table of Auto OFF Error messagesPower OFF on Counter display Monitor display Description VTR operationServo Control External interface specifications Hardware specificationsRS-232C interface IntroductionProtocol Software specificationsACK STX OPL ETX Error code tableCommands relating to operation control Notes Command tableReverse STX OSR ETXStandby STX OBF ETX Standby STX OBN ETXCommands relating to inquiries Notes CLS Microsoft QuickBASIC sample programPin No. Signal Connector signalsSignal Transmit CommonRS-232C Remote 25-pin D-SUB crossover cable supported Preroll CommandFrame Ground GND