Table of AUTO OFF Error messages
Counter display | Monitor display |
| Description | VTR operation | |
| (Restart condition) | ||||
|
|
|
| ||
|
|
|
| ||
CAP ROTATE TOO | CAP ROTA TOO | If the capstan motor speed is abnormally low, the | STOP | ||
SLOW | SLOW | AUTO OFF lamp lights, and the message display | |||
(POWER OFF→ON) | |||||
|
| flashes. |
| ||
CAP TENSION ERROR | CAP TENSION ERROR | If an abnormal tension at the supply side is detected | STOP | ||
|
| in the capstan mode, the AUTO OFF lamp lights, and | |||
|
| the message display flashes. | (POWER OFF→ON) | ||
|
|
| |||
|
|
|
| ||
DEW | DEW | If condensation is detected, the AUTO OFF lamp | EJECT | ||
|
| lights, the message display flashes, and the VTR is | |||
|
| transferred to the eject mode. After the tape is | (Normal operation | ||
|
| ejected, the drum rotates in order to eliminate the | resumed after | ||
|
| condensation. | condensation is | ||
|
| When the condensation has been eliminated, the | eliminated) | ||
|
| AUTO OFF lamp and message display go off, and the |
| ||
|
| VTR can be used. |
| ||
|
| <Notes> |
| ||
|
| 1) | If condensation is detected in the eject mode, the |
| |
|
| 2) | drum starts rotating as soon as it is detected. |
| |
|
| If condensation is detected when the cassette has |
| ||
|
|
| been inserted, the drum rotation is stopped, and |
| |
|
|
| after the tape is ejected, the drum starts rotating. |
| |
|
|
|
| ||
DRUM ROTATE TOO | DRUM ROTA TOO | If the cylinder motor speed is abnormally high, the | STOP | ||
FAST | FAST | AUTO OFF lamp lights, and the message display | (POWER OFF→ON) | ||
|
| flashes. |
| ||
DRUM ROTATE TOO | DRUM ROTA TOO | If the cylinder motor speed is abnormally low, the | STOP | ||
SLOW | SLOW | AUTO OFF lamp lights, and the message display | (POWER OFF→ON) | ||
|
| flashes. |
| ||
If the tape start and tape end are detected simulta- | STOP | ||||
| neously either during or after loading, the AUTO OFF | → | |||
|
| lamp lights, and the message display flashes. | (POWER OFF ON) | ||
|
|
| |||
|
|
|
| ||
FRONT LOAD ERROR | FRONT LOAD ERROR | The AUTO OFF lamp lights and the message display |
| ||
|
| flashes when the | STOP | ||
|
| for a fixed period of time while the start/end | (POWER OFF→ON) | ||
|
| processing operation during loading (half position) is |
| ||
|
| being performed. |
| ||
|
|
|
| ||
FRONT LOAD MOTOR | FRONT LOAD MOTOR | If the cassette does not move up even when 6 |
| ||
|
| seconds have elapsed since the VTR was transferred |
| ||
|
| to the eject mode, the AUTO OFF lamp lights, and the |
| ||
|
| message display flashes. | STOP | ||
|
| <Note> | |||
|
| (POWER OFF→ON) | |||
|
| If the cassette does not move down inside the | |||
|
| machine even when 6 seconds have elapsed since |
| ||
|
| the cassette was inserted, the VTR is transferred to |
| ||
|
| the eject mode. |
| ||
|
|
|
| ||
LOADING MOTOR | LOADING MOTOR | When the unloading operation is not completed within |
| ||
|
| 6 seconds, the AUTO OFF lamp lights, and the |
| ||
|
| message display flashes. | STOP | ||
|
| <Note> | |||
|
| (POWER OFF→ON) | |||
|
| When the loading operation is not completed within 6 | |||
|
| seconds, the VTR is transferred to the eject (unload- |
| ||
|
| ing) mode. |
| ||
|
|
|
|
|
– 74 –