5.2 FLUORESCENT DISPLAY
1 2 | 3 | 4 | 5 | 78 | 9 | A |
6
M | PL | ALARM | INDEX | MODE |
|
|
|
|
|
|
| SP | EP |
|
|
|
|
|
| SKIP | S | E | |
|
|
|
| EMGCY | PLAY | REC | |
|
|
|
| H | LOCK |
FE D C B
1.M (counter memory) indicator
Illuminates during rewind for counter memory mode.
2.PL (power loss) indicator
Illuminates when there is a power failure during recording.
3.ALARM indicator
Flashes during alarm recording and stays on when the alarm recording is finished.
4.INDEX indicator
Flashes during recording of the date/hour index signal and lights during an index search.
5.MODE display
Displays the selected recording or playback mode. EP lights to indicate recording in 6H, L18H, 72H, or 96H mode or when playing back a tape recorded in those modes. SP lights to indicate recording in 2H mode when playing back a tape recorded in that mode.
6.SKIP indicator
Illuminates during skip search.
7.Repeat indicator
Illuminates when TAPE END in the First Time Set Up menu is set to REPEAT or ALARM•PROT.
8.Cassette status indicator
Illuminates when you insert the tape. The light advances, stops, or flashes corresponding to the movement of the tape.
9.Timer recording indicator
Illuminates when the TIMER REC button is set to ON.
10.Tape remaining indicator
Indicates the approximate tape position (S = start, E = end).
11.REC indicator
Illuminates during recording.
12.PLAY indicator
Illuminates during playback.
13.EMGCY (emergency recording) indicator
Illuminates when EMERGENCY REC in the Recording Set Up menu is set to ON.
14.LOCK indicator
Illuminates when the lock feature is in use.
15.Counter display
Indicates the relative position of the tape.
Figure 4. Fluorescent Display
16 | Pelco Manual C651M (7/99) |