CONNECTING A CM9760-CC1

To connect a CM9760-CC1 to a DX9100 recorder:

1.Connect a null modem cable from the CM9760-DT’s COM A port to the recorder’s RS-232 port.

2.Connect a null modem cable from the CM9760-DT’s COM B port to COM 1 or COM 2 port on the CM9760-CC1.

3.Set the jumpers in the data translator for baud rate and parity. Refer to the CM9760-DT Installation/Operation manual.

NOTE: You can also connect the CM9760-DT to one of the CM9760-CC1 SERCOM ports for RS-422 communication.

RECORDER

1

4

 

9

12

 

5

8

 

13

16

Term

75

Term

 

75

Te rm

 

75

Te rm

 

75

Loop

 

HI-Z

Loop

 

HI-Z

Loop

 

HI-Z

Loop

 

 

HI-Z

In

1

2

3

4

5

6

7

8

Ou t

In

9

10

11

12

13

14

15

16

Ou t

Re l

A larm

Input s

Re l

A larm Input s

1

1 2 3 4 5

6 7 8 Co m

2

9 10 11 12 13 14 15 16 C om

AUDIO INPUTS

1

5

9

13

2

6

10

14

3

7

11

15

4

8

12

16

NULL MODEM

CABLE

CM9760-DT

COM A

COM B

1 2

12 VAC

 

NULL MODEM

 

RS-232 TO RS-422

CABLE

 

 

CONVERTER

 

 

 

 

CM9760-CC1

 

1

2

PRINTER

COM 1

COM 2

Figure 84. Connecting a CM9760-CC1

NOTE: You do not have to use a CM9760-DT if the CM9760-CC1 has software version 8.0. However, you must set the COM port on the CC1 as an internal data translator. Refer to the CM9760-CC1 Installation/Operation manual.

C636M-F (3/09)

69

Image 69
Contents DX9100 Series Contents C636M-F 3/09 List of Illustrations 100 List of Tables Important Safety Instructions DX9100DVR Series Regulatory NoticesDescription DX9100VSR ModelsFront View of Recorder Front View RecorderBack View of Recorder Back View RecorderFront View of Viewstation Front View ViewstationBack View of Viewstation Back View ViewstationWindows 2000 license label on unit Installation Guidelines Mounting DX9100 Rack Mount Installation Connections System Connections Wiring Alarms and Relays Power UP the Equipment Programming Viewstation Network ConfigurationChanging the VIEWSTATION’S Identification Viewstation Local Area Connection Status Dialog Box Changing the VIEWSTATION’S IP Address and Subnet MaskClick Properties. The following dialog box appears Changing the RECORDER’S Identification Time Synchronization Time Zone Setting DATE/TIME PropertiesClient Configuration Utility C636M-F 3/09 Recorder Initialization Options DX9116F Frame Rate and ResolutionC636M-F 3/09 Go to Start Programs DX9000 Viewstation Server State Server StateError Alert Advanced Recorder Options Database Backup and RepairSystem Tray Database RestorationMy Computer Window Databases Window Rename Mssql to MSSQLold Mssql Folders Delete MSSQLold C636M-F 3/09 Restore Utility Dialog Box Go to the system tray Start/Continue Window C636M-F 3/09 Finished Scan Dialog Box Alarm Modes/Relay Intervals Dialog Box Configuring Standard Alarm and Relay PropertiesCamera Properties Dialog Box Camera Recording PropertiesContinuous Recording Schedule Daily Recording Schedule Continuous Recording ScheduleDaily Event Recording Continuous Weekly Recording Schedule Weekly Recording ScheduleMotion Detection Motion DetectionCamera Video Setup Channel SetupParameter Description/Action User Manager Dialog Box Defining UsersEdit Existing Users Interface HandlerManager Recorder Connecting AN Alarm UnitCM9760 Alarm Driver Dialog Box Select CM9760ALM.dll Alarm Unit ConfigurationClick Open. The following dialog box appears Manager for Alarm Unit Sample Configuration for External 1 Source Click Next. The following dialog box appears Connecting a CM9760-REL Connecting a Relay UnitCM9760 Relay Driver Dialog Box Select CM9760REL.dll Relay Unit ConfigurationClick Open. The following dialog box appears Manager for Relay Unit Click Next. The following dialog box appears CM9760-DT Connecting a CM9760-CC1Connecting a CM6800 Connecting a CM6800CM9760 Data Translator Driver Dialog Box Select CM9760DT.dll Data Translator ConfigurationClick Open. The following dialog box appears Manager for Data Translator Click Next. The following dialog box appears Data Translator Connections DVR ManagementConfiguring the Data Translator Click Configure. The following dialog box appears Relay Unit Connections Connecting a CM9760-REL for DVR ManagementConfiguring the Relay Unit Click Configure. The following dialog box appears Foreign Language Programming Click Set Default. The following dialog box appears Specifications Viewstation Product Warranty and Return Information