VIEWSTATION

 

Electrical

 

Input Voltage

100 to 240 VAC, 50/60 Hz, autoranging

Power Consumption

90 W maximum

Operating System

Windows 2000 and SP2 Service Pack

Mechanical

 

Connectors

 

6-pin mini-DIN

PS/2 mouse and keyboard

DB9

Two RS-232 COM ports available for external devices

DB15

SVGA monitor port (1024 x 768)

DB15

Composite monitor port (analog adapter provided)

DB25

Printer port

RJ-11

Internal modem (for use with pcAnywhere software only)

RJ-45

Ethernet port (10/100Base-T)

 

Ethernet port (10/100/1000Base-T)

USB

2 ports available

RCA

Audio output (reserved for future use)

DVI

Flat panel/LCD display

Hardware

 

Processor

Pentium® 4, 2.4 GHz

RAM

512 MB DDR

Video card

ATI RadeonTM 9600 PRO

Modem

V.90/56K

Drive

DVD-RW/CD-RW

General

 

Operating Temperature

41˚ to 85˚F (5˚ to 29˚C)

Relative Humidity

Maximum 80%, noncondensing

Dimensions

 

Desktop

19.6" D x 17.0" W x 7.3" H (49.8 x 43.2 x 18.5 cm)

Rack Mount

19.6" D x 19.0" W x 7.0" H (49.8 x 48.3 x 17.8 cm)

Unit Weight

33 lb (15.0 kg)

84

C636M-F (3/09)

Image 84
Contents DX9100 Series Contents C636M-F 3/09 List of Illustrations 100 List of Tables Important Safety Instructions Regulatory Notices DX9100DVR SeriesDescription Models DX9100VSRFront View Recorder Front View of RecorderBack View Recorder Back View of RecorderFront View Viewstation Front View of ViewstationBack View Viewstation Back View of ViewstationWindows 2000 license label on unit Installation Guidelines Mounting DX9100 Rack Mount Installation Connections System Connections Wiring Alarms and Relays Power UP the Equipment Viewstation Network Configuration ProgrammingChanging the VIEWSTATION’S Identification Changing the VIEWSTATION’S IP Address and Subnet Mask Viewstation Local Area Connection Status Dialog BoxClick Properties. The following dialog box appears Changing the RECORDER’S Identification Time Synchronization Setting DATE/TIME Properties Time ZoneClient Configuration Utility C636M-F 3/09 DX9116F Frame Rate and Resolution Recorder Initialization OptionsC636M-F 3/09 Server State Go to Start Programs DX9000 Viewstation Server StateError Alert Database Backup and Repair Advanced Recorder OptionsDatabase Restoration System TrayMy Computer Window Databases Window Rename Mssql to MSSQLold Mssql Folders Delete MSSQLold C636M-F 3/09 Restore Utility Dialog Box Go to the system tray Start/Continue Window C636M-F 3/09 Finished Scan Dialog Box Configuring Standard Alarm and Relay Properties Alarm Modes/Relay Intervals Dialog BoxCamera Recording Properties Camera Properties Dialog BoxContinuous Recording Schedule Continuous Recording Schedule Daily Recording ScheduleDaily Event Recording Weekly Recording Schedule Continuous Weekly Recording ScheduleMotion Detection Motion DetectionChannel Setup Camera Video SetupParameter Description/Action Defining Users User Manager Dialog BoxEdit Existing Users Interface HandlerManager Connecting AN Alarm Unit RecorderAlarm Unit Configuration CM9760 Alarm Driver Dialog Box Select CM9760ALM.dllClick Open. The following dialog box appears Manager for Alarm Unit Sample Configuration for External 1 Source Click Next. The following dialog box appears Connecting a Relay Unit Connecting a CM9760-RELRelay Unit Configuration CM9760 Relay Driver Dialog Box Select CM9760REL.dllClick Open. The following dialog box appears Manager for Relay Unit Click Next. The following dialog box appears Connecting a CM9760-CC1 CM9760-DTConnecting a CM6800 Connecting a CM6800Data Translator Configuration CM9760 Data Translator Driver Dialog Box Select CM9760DT.dllClick Open. The following dialog box appears Manager for Data Translator Click Next. The following dialog box appears DVR Management Data Translator ConnectionsConfiguring the Data Translator Click Configure. The following dialog box appears Connecting a CM9760-REL for DVR Management Relay Unit ConnectionsConfiguring the Relay Unit Click Configure. The following dialog box appears Foreign Language Programming Click Set Default. The following dialog box appears Specifications Viewstation Product Warranty and Return Information