CHECK THE ALARM RECORD INFORMATION
MAIN MENU
MENU
VCR SET UP
REC MODE SET UP
TIMER REC SET UP
GALARM SET UP POWER FAIL RECALL LANGUAGE ENGLISH
(MOVE) (SELECT) (MENU)
ALARM REC MODE MENU
ALARM SET UP |
|
REC MODE | 6H |
DURATION | 1 MIN |
BUZZER | ON |
ALARM READY | ON |
G ALARM RECALL |
|
(MOVE) (SELECT) (MENU)
| ALARM RECALL |
| ||
1 | 01/01/03 | 00:21:13 | ||
G 2 | 01/02/03 | 04:07:37 | ||
3 | 01/03/03 | 03:59:36 | ||
4 | - | / - - | - | : - - |
5 | - | / - - | - | : - - |
6 | - | / - - | - | : - - |
7 | - | / - - | - | : - - |
8 | - | / - - | - | : - - |
(UP) (DOWN) (CLEAR) (MENU)
To check or cancel the Alarm Record Information, use the ALARM RECALL function.
1 Press MENU button and the main menu will appear.
2 Press MOVE to choose the ALARM SET UP item and then press SEL.
ALARM SET UP menu will appear.
3 Press MOVE to choose the ALARM RECALL item and then press SEL.
ALARM RECALL menu will appear.
To erase the alarm record inform
If you want to erase the alarm record information, press the CLEAR button.
4 Press MENU when finished. Press MENU repeatedly to exit menu screen.
NOTES:
•Alarm recall can memorize up to 16 alarms, but only 8 can be dis- played on the monitor. Press MOVE repeatedly to see the next page.
RECORDING TIME TABLE INFORMATION
Recording Time | Field / sec (NTSC) | Field / sec (PAL) |
6H | 60 | 50 |
18H | 20 | 16.67 |
|
|
|
30H | 12 | 10 |
|
|
|
72H | 4.62 | 3.85 |
|
|
|
96H | 3.53 | 2.94 |
|
|
|
120H | 2.86 | 2.38 |
|
|
|
168H | 2.07 | 1.72 |
|
|
|
240H | 1.46 | 1.22 |
|
|
|
480H | 0.74 | 0.62 |
|
|
|
960H | 0.37 | 0.31 |
|
|
|
ADDITIONAL INFORMATION
27