LOREX Technology SG7965 instruction manual Self-Diagnosis, Error Code Table

Page 29

SELF-DIAGNOSIS

This function informs you of error messages to help solve problems more easily. When the VCR malfunctions, an error code is displayed in the VCR indicator panel.

ERROR CODE TABLE

DISPLAY

DESCRIPTION

 

INPUT SIGNAL

CIRCUIT STATUS

SERVICE POINTS

 

 

 

 

 

 

 

Loading Motor Error

Mode Switch

• Mode Switch Position not

• Loading Motor Drive

 

 

 

S1,S2,S3,S4

changed within 6 seconds

IC

 

 

Load Motor +, -

after cassette loading attempt.

• Loading Motor

 

 

 

 

 

• Mode Switch

 

 

 

 

 

 

 

Tape Loading Error

Mode Switch

• Mode Switch Position not

• Mode Switch

 

 

 

S1,S2,S3,S4

changed within 6 seconds

contacts

 

 

Load Motor +, -

after cassette loading attempt.

 

 

 

 

 

 

 

 

Tape Eject Error

Mode Switch

• CST Switch must be activat-

• CST IN Switch

 

 

 

S1,S2,S3,S4

ed within 3 seconds, other-

contacts

 

 

CST IN Switch

wise unit shut down will occur.

 

 

 

Load Motor +, -

 

 

 

 

 

 

 

 

Reel Rotational Error

Supply/Take-up

• CFG Signal present, but take-

• Capstan belt

 

 

 

Reel Pulses

up pulses are missing.

• Idler and reel gears

 

 

• CFG

(Capstan motor running.)

damaged

 

 

 

 

 

 

Drum Motor Error

• DFG Switch

• Drum Motor (Slow Start)

• Drum Motor and

 

 

• DPF

• Motor must be up to speed

Control Circuits

 

 

 

 

within 3 seconds of operation.

 

 

 

 

 

 

 

When a malfunction occurs in the VCR, press the POWER/TIMER button on the front of VCR to operate normally.

An error message (Err) appears in the display continuously when any button is pressed; contact your dealer or service center.

ADDITIONAL INFORMATION

29

Image 29
Contents Professional 1280 Hr Time Lapse VCR Introduction Moisture CondensationFeatures Contents Control Names and Locations Alarm Indicator POWER/TIMER buttonKEY Lock Indicator Menu buttonAudio IN/OUT Jack Reset Button Power Cord Video IN/OUT JackConnect only to an AC 100-240V, 50/60Hz Outlet TerminalStop Remote ControlEject Cassette Indication VCR Function Indication CLOCK, Tape COUNTER, ErrorLock Repeat Installation Multiplexer Connections HOW to Connect Multiplexer with Trigger Input TerminalHOW to Connect Switcher Without Trigger Input Terminal Matrix Switcher ConnectionsSeries Record Connection Alarm Record ConnectionMain Menu Settings the on Screen DisplayMenu Selection Setting the VCR SET UP Menu Time and Date display position change Setting the SET TimeClock SET UP Menu When Handling Video Cassettes Safety TABVideo Cassette Tapes LoadingTracking Control Normal PlaybackNormal Playback During Playback mode To Search Alarm RecordingSpecial Effects Playback To Watch a Still PictureShuttle Ring During Still modeJOG Dial Jog DialWhen the Counter is displayed Tape Counter Memory FeatureReal Time Counter Counter Memory FunctionNormal Recording During the Recording modeRepeat Recording REC Mode MenuTimer REC Mode Menu Timer RecordingDAY option Recording, press STOP/EJECT buttonSeries Recording Alarm SET UP Alarm RecordingFor example When the Alarm REC Mode is set to 6H Alarm Recording cont’dRecording Time Table Information Check the Alarm Record InformationAlarm REC Mode Menu KEY Lock Function Check the Power Fail RecallPower Fail Inform Menu SELF-DIAGNOSIS Error Code TableVideo Head Cleaning Service Guide TableSymptom Check Point & Correction TroubleshootingGeneral Specifications