LOREX Technology SG7965 instruction manual Troubleshooting, Symptom Check Point & Correction

Page 31

TROUBLESHOOTING

SYMPTOM

 

CHECK POINT & CORRECTION

Cassette cannot be inserted.

• Load cassette in direction indicated by arrow on cassette.

 

• A cassette is already in the VCR.

 

• Check if power indicator is lit on the VCR indicator panel. If not,

 

make sure power cord is plugged in.

 

• If the

indicator flashes, press the POWER/TIMER button

 

again.

 

 

 

The VCR will not go into the

• The cassette has had the erase prevention tab removed. Stick a

recording mode, even when

piece of cellophane tape over the erase prevention tab hole or

REC button is pressed.

select a different cassette.

 

 

No picture appears on monitor

• Try a different cassette tape.

screen when PLAY/REC CHK

• Try to confirm that the system is connected correctly.

button is pressed.

 

 

 

 

No picture, but audio is clear.

• The heads may require cleaning.

 

• Take VCR to a qualified Service Center for service.

 

 

Interference on playback

• Adjust fine tuning knob on monitor to obtain best picture.

picture.

• Adjust TRACKING (MOVE / SEL) control button.

 

• Take VCR to Service Center for service.

 

 

VCR does not start at preset

• Setup recording time according to instructions.

record starting time.

 

 

 

 

The tape is ejected in the timer

• The cassette has had the erase prevention tab removed. Stick a

or alarm recording mode.

piece of cellophane tape over the erase prevention tab hole or

 

select a different cassette.

 

 

indication flashes.

• Insert a cassette.

 

 

 

Using the RESET button (located at the rear panel of VCR)

This button is used to solve the problems exhibited by the following symptoms :

When the power cannot be turned on, even if the power cord is connected to the outlet.

When the VCR’s display does not display.

When the VCR does not operate normally.

- Use a pencil or ballpoint pen to press the RESET button.

NOTES:

If the RESET button is pressed, then all memorized data will be cleared, such as timer program, present time, alarm information, etc.

If the present time is cleared, set the clock again.

ADDITIONAL INFORMATION

31

Image 31
Contents Professional 1280 Hr Time Lapse VCR Introduction Moisture CondensationFeatures Contents Control Names and Locations Menu button POWER/TIMER buttonAlarm Indicator KEY Lock IndicatorOutlet Terminal Power Cord Video IN/OUT JackAudio IN/OUT Jack Reset Button Connect only to an AC 100-240V, 50/60HzEject Remote ControlStop Lock Repeat CLOCK, Tape COUNTER, ErrorCassette Indication VCR Function Indication Installation Multiplexer Connections HOW to Connect Multiplexer with Trigger Input TerminalHOW to Connect Switcher Without Trigger Input Terminal Matrix Switcher ConnectionsSeries Record Connection Alarm Record ConnectionMenu Selection Settings the on Screen DisplayMain Menu Setting the VCR SET UP Menu Clock SET UP Menu Setting the SET TimeTime and Date display position change Loading Safety TABWhen Handling Video Cassettes Video Cassette TapesNormal Playback Normal PlaybackTracking Control To Watch a Still Picture To Search Alarm RecordingDuring Playback mode Special Effects PlaybackJog Dial During Still modeShuttle Ring JOG DialCounter Memory Function Tape Counter Memory FeatureWhen the Counter is displayed Real Time CounterNormal Recording During the Recording modeRepeat Recording REC Mode MenuRecording, press STOP/EJECT button Timer RecordingTimer REC Mode Menu DAY optionSeries Recording Alarm SET UP Alarm RecordingFor example When the Alarm REC Mode is set to 6H Alarm Recording cont’dAlarm REC Mode Menu Check the Alarm Record InformationRecording Time Table Information Power Fail Inform Menu Check the Power Fail RecallKEY Lock Function SELF-DIAGNOSIS Error Code TableVideo Head Cleaning Service Guide TableSymptom Check Point & Correction TroubleshootingGeneral Specifications