LOREX Technology SG7965 Power Cord Video IN/OUT Jack, Connect only to an AC 100-240V, 50/60Hz

Page 6

CONTROL NAMES AND LOCATIONS (cont’d)

REAR

2

3

1

PREPARATION

1

ALARM IN

 

 

VIDEO IN

2

ALARM OUT

 

 

AUDIO IN

3

ALARM RESET

 

 

 

4

GND

 

 

 

5

SERIES IN

 

 

 

6

SERIES OUT

 

 

 

7

WARNING OUT

 

 

 

8

TRIGGER OUT

 

 

 

9

GND

 

 

 

10

LOW TAPE OUT

1 2 3 4

5 6 7 8 9 10 11 12

AUDIO OUT

11

1 SHOT REC IN

 

 

12

GND

 

 

 

 

RESET

 

 

 

 

 

 

 

VIDEO OUT

 

 

 

 

4

 

5

 

1.

POWER CORD

3.

VIDEO IN/OUT JACK

 

Connect only to an AC 100-240V, 50/60Hz

 

Connect the video input and output

 

outlet.

 

terminal.

 

 

2.

AUDIO IN/OUT JACK

4.

RESET BUTTON

 

Connect the audio input and output

 

Use this button to reset the VCR.

 

terminal.

5.

12-PIN TERMINAL BLOCK

 

 

Connect external signals.

Terminal Signal Levels

TERMINAL

 

 

 

SIGNAL LEVEL

IN/OUT

 

 

 

 

 

 

 

 

1. ALARM IN

 

VIH

 

VIL

VIH: 4~5V, VIL: 0~0.6V

INPUT

 

 

 

T

T: above 250msec

 

 

 

 

 

 

 

2. ALARM OUT

 

VOH

 

VOL

 

VOH: 4~5V, VOL: 0~0.6V

OUTPUT

 

 

 

 

 

 

 

 

T

 

 

T: ALARM REC STATE

 

3. ALARM RESET

 

 

 

 

 

 

INPUT

 

VIH

 

VIL

VIH: 4~5V, VIL: 0~0.6V

 

 

 

T

T: above 250msec

 

 

 

 

 

 

 

5. SERIES IN

 

 

 

 

 

VIH: 4~5V, VIL: 0~0.6V

INPUT

VIH

 

VIL

 

 

 

T

T: above 250msec

 

 

 

 

 

 

 

6. SERIES OUT

 

 

 

 

 

 

OUTPUT

VOH

 

VOL

VOH: 4~5V, VOL: 0~0.6V

 

 

 

T

T: above 250msec

 

 

 

 

 

 

 

7. WARNING OUT

 

 

 

 

 

 

OUTPUT

VOH

 

VOL

VOH: 4~5V, VOL: 0~0.6V

 

 

 

T

T: until any key is pressed

 

 

 

 

 

 

 

8. TRIGGER OUT

 

 

 

 

 

 

OUTPUT

 

VOH

 

VOL

VOH: 4~5V, VOL: 0~0.6V

 

 

 

T

T: above 8~10msec

 

 

 

 

 

 

 

10. LOW TAPE OUT

 

 

 

 

 

 

OUTPUT

 

VOH

 

VOL

VOH: 4~5V, VOL: 0~0.6V

 

 

 

T

T: below 5 min, end of tape

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11. 1-SHOT REC IN

 

VIH

 

VIL

VIH: 4~5V, VIL: 0~0.6V

INPUT

 

 

 

T

T: above 250msec

 

 

 

 

 

 

 

4, 9, 12. GND

 

 

 

 

0V

COMMON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Image 6
Contents Professional 1280 Hr Time Lapse VCR Moisture Condensation IntroductionFeatures Contents Control Names and Locations KEY Lock Indicator POWER/TIMER buttonAlarm Indicator Menu buttonConnect only to an AC 100-240V, 50/60Hz Power Cord Video IN/OUT JackAudio IN/OUT Jack Reset Button Outlet TerminalRemote Control EjectStop CLOCK, Tape COUNTER, Error Lock RepeatCassette Indication VCR Function Indication Installation HOW to Connect Multiplexer with Trigger Input Terminal Multiplexer ConnectionsMatrix Switcher Connections HOW to Connect Switcher Without Trigger Input TerminalAlarm Record Connection Series Record ConnectionSettings the on Screen Display Menu SelectionMain Menu Setting the VCR SET UP Menu Setting the SET Time Clock SET UP MenuTime and Date display position change Video Cassette Tapes Safety TABWhen Handling Video Cassettes LoadingNormal Playback Normal PlaybackTracking Control Special Effects Playback To Search Alarm RecordingDuring Playback mode To Watch a Still PictureJOG Dial During Still modeShuttle Ring Jog DialReal Time Counter Tape Counter Memory FeatureWhen the Counter is displayed Counter Memory FunctionDuring the Recording mode Normal RecordingREC Mode Menu Repeat RecordingDAY option Timer RecordingTimer REC Mode Menu Recording, press STOP/EJECT buttonSeries Recording Alarm Recording Alarm SET UPAlarm Recording cont’d For example When the Alarm REC Mode is set to 6HCheck the Alarm Record Information Alarm REC Mode MenuRecording Time Table Information Check the Power Fail Recall Power Fail Inform MenuKEY Lock Function Error Code Table SELF-DIAGNOSISService Guide Table Video Head CleaningTroubleshooting Symptom Check Point & CorrectionSpecifications General