JVC KV-V8 service manual Precaution, Required test equipments, Required adjustment tools

Page 25

SECTION 3

ELECTRICAL ADJUSTMENT

3.1Precaution

The following adjustment procedures are not only necessary after replacement of consumable mechanical parts or board assemblies, but are also provided as references to be re- ferred to when servicing the electrical circuitry.

In case of trouble with the electrical circuitry, always begin a service by identifying the defective points by using the meas- uring instruments as described in the following electrical ad- justment procedures. After this, proceed to the repair, replace- ment and / or adjustment. If the required measuring instru- ments are not available in the field, do not change the adjust- ment parts (variable resistor, etc.) carelessly.

3.1.1 Required test equipments

Color (colour) television or monitor

Oscilloscope: wide-band, dual-trace, triggered delayed sweep

Digit-key remote controller (provided)

3.1.2 Required adjustment tools

Jig RCU

Alignment tape

Alignment tape

PTU94023B

(SP, stairstep, NTSC)

(EP, stairstep, NTSC)

 

MHP

MHP-L

Alignment tape

Alignment tape

Alignment tape

(SP, stairstep, PAL)

(LP, stairstep, PAL)

(SP, color (colour) bar, NTSC)

MHPE

MHPE-L

MH-1

Alignment tape

Alignment tape

Alignment tape

(EP, color (colour) bar, NTSC)

(SP, color (colour) bar, PAL)

(LP, color (colour) bar, PAL)

MH-1L

MH-2

MH-2L

3.1.3 Switch settings and standard precautions

The SW settings of the VCR and the standard precautions for the electrical adjustments are as follows.

When using the Jig RCU, set its custom code to match the custom code of the VCR.

Jig RCU

[Data transmitting method] Depress the “ ” ( 3 ) button after the data code is set.

CUSTOM CODE

 

 

 

 

 

 

 

INITIAL MODE

43: A CODE

 

 

 

 

 

 

 

 

53:B CODE DATA CODE

Fig. 3-1-3a Jig RCU [PTU94023B]

Unless otherwise specified, all measuring points and adjustment parts are located on the Main board.

When checking the operation or performing adjust- ments to the VCP main unit, it is necessary to connect the power cable (Car Cable) to the VCP main unit so that DC power is supplied. Also, when using the re- mote control unit, it is required to connect the IR re- ceiver. (by using either the provided or operational ac- cessories)

3.2Servo circuit

3.2.1 Switching point

Signal

(A1)

• Stairstep signal

 

 

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

 

 

[KV-V8E]

 

(A2)

• Alignment tape (SP, stairstep, PAL) [MHPE]

 

 

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

 

 

[KV-V8J]

 

(A2)

• Alignment tape (SP, stairstep, NTSC) [MHP]

 

 

 

Mode

(B)

• PB

 

 

 

Equipment

(C)

• Oscilloscope

 

 

 

Measuring point

(D1)

• VIDEO OUT terminal (75Ø terminated)

 

(D2)

• TP106 (PB FM)

 

 

 

External trigger

(E)

• TP111 (D.FF)

 

 

 

Adjustment part

(F)

• Jig RCU: Code “5A”

 

 

 

 

 

[KV-V8E]

Specified value

(G)

• 6.5 ± 0.5 H (SP, stairstep, PAL) [MHPE]

 

 

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

 

 

[KV-V8J]

 

(G)

• 6.5 ± 0.5 H (SP, stairstep, NTSC) [MHP]

 

 

 

Adjustment tool

(H)

• Jig RCU [PTU94023B]

 

 

 

(1)Play back the signal (A1) of the alignment tape (A2).

(2)Apply the external trigger signal to D.FF (E) to observe the VIDEO OUT waveform and V.PB FM waveform at the measuring points (D1) and (D2).

(3)Set the VCR to the manual tracking mode.

(4)Adjust tracking so that the V.PB FM waveform becomes maximum.

(5)Set the VCR to the Auto adjust mode by transmitting the code (F) from the Jig RCU. When the VCR enters the stop mode, the adjustment is completed.

(6)If the VCR enters the eject mode, repeat steps (1) to (5) again.

(7)Play back the alignment tape (A2) again, confirm that the switching point is the specified value (G).

Trigger point

 

 

 

 

 

 

V.sync

 

 

 

 

 

 

 

 

 

 

 

Switching point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V. rate

Fig. 3-2-1a Switching point

3-1

Image 25
Contents KV-V8 Specificatios KV-V8J How to read the disassembly and assembly Disassembly flow chartAdjustment information for installation Disassembly/assembly methodFig. D1 Fig. D4 How to set the Service position Service positionMechanism service mode How to set the Mechanism service modeFDP display model FDP display FDP Content Cause EMG detail information Mechanism sensor information Common table of MN*, HD* and M3 Jigs and tools required for adjustment Before starting repair and adjustment PrecautionsChecking for proper mechanical operations Manually removing the cassette tape5a Mechanism assembly top side Lubrication CleaningTape DriveHow to set the Mechanism assembling mode Replacement of major parts Before starting disassemblingPinch roller arm assembly 4 A/C head How to removeReel disk assembly take up Lever assembly, sub deck assembly, capstan motorLoading motor Control bracketControl plate Sub brake assembly take up, control camSlide plate Take up head, tension arm lever Change lever assembly, rotary encoderRemove the take up head and tension arm lever Stator assembly Rotor assembly How to removeUpper drum assembly Guide rail19a Loading arm assemblies supply, take up Rotary encoder, change lever assembly, control camAttach the surrounding parts of the guide rail Mechanism timing chart Repeat steps 1 to 10 by using the alignment tape A2 Compatibility adjustment NotesFM waveform linearity Height and tilt of the A/C head 3 A/C head phase X-valuePlay back the alignment tape a Tension pole position Standard tracking presetRequired adjustment tools PrecautionSwitch settings and standard precautions Required test equipmentsSlow tracking preset No.49625 KV-V8