JVC SR-9090U instruction manual Preparation, Cassette Loading/Unloading, Auto operate on Auto play

Page 14

4 ON-SCREEN/MENU SWITCHES

4-7 Contents of Menu Switches

[ ]: Factory setting

• The lower section in the items and set values columns shows what’s on the VCR’s display.

 

 

 

 

 

 

Screens

 

Items

 

Set values

Function

 

 

 

 

ALARM/

DURATION

5 SEC

Selects the recording duration for alarm or sensor recording.

 

 

 

10 SEC

5 — 180 SEC: Alarm or sensor recording is performed for the specified

SENSOR

 

 

 

 

 

 

15 SEC

time (5 sec. to 180 sec.)

MODE

 

 

 

 

 

 

30 SEC

TAPE END: Alarm or sensor recording continues to the end of the tape.

 

 

 

 

 

 

 

 

60 SEC

 

 

 

 

MANUAL: Alarm or sensor recording continues for as long as alarm

 

 

 

 

120 SEC

 

 

 

 

signals are input. Set to this position when specifying the

 

 

 

 

[180 SEC]

 

 

 

 

alarm recording time with a switcher.

 

 

 

 

TAPE END

 

 

 

 

*To ensure accurate alarm search and alarm scan operation,

 

 

 

 

MANUAL

 

 

 

 

be sure to set the recording time to 5 seconds or more.

 

 

 

 

5.

 

(VCR's display)

 

 

AL

SE

3

.

 

 

.

 

 

 

 

 

180

 

 

 

 

 

TPEN

 

 

 

 

 

NANU

 

 

TAPE END

[OFF]

Selects whether or not the Stop mode is forcibly engaged when the tape

 

MODE

 

STOP

ends even if there is an alarm or sensor recording.

 

 

 

 

OFF

OFF: The forced Stop mode is not engaged.

 

AL

SE

4

• When the tape ends, the mode set with the menu switch <AUTO

 

 

 

 

STOP

REW> or <REPEAT REC> on the <VTR MODE> screen is engaged.

 

 

 

 

 

STOP: The Forced Stop mode is engaged.

 

 

 

 

BUZZER

TAPE END

[OFF]

Sets whether or not the buzzer sounds when the tape ends in the

 

 

 

 

ON

Record mode.

 

BU

22

1

OFF

OFF: The buzzer does not sound.

 

ON: The buzzer sounds when the tape ends during recording. Also, the

 

 

 

 

ON

buzzer sounds when the tape reel counter value set with the menu

 

 

 

 

 

switch <CNT TAPE END> on the SRI/EXT MODE screen is reached.

 

 

 

 

 

When the mode is changed by pressing the [REW] button,

 

 

 

 

 

[EJECT] button or [OPERATE] button, the buzzer sound stops.

 

 

 

 

 

AL/SENSOR

[OFF]

Selects whether or not the buzzer sounds during alarm or sensor

 

IN

 

 

ON

recording.

 

BU

22

2

OFF

OFF: The buzzer does not sound.

 

ON: The buzzer sounds.

 

 

 

 

ON

 

 

 

 

 

5 PREPARATION

5-1 Cassette Loading/Unloading

Loading

Insert the cassette with its label side facing you.

Gently push the center of the cassette until the machine starts automatic loading.

 

 

 

 

 

 

 

 

 

SR-

9090U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REC

 

 

REC

STOP

REC

 

 

 

 

 

 

EJECT OPERATE

 

 

 

CHECK

 

 

 

 

OPERATE

 

 

 

 

 

 

 

 

 

 

 

HDR

RESET/

ON SCREEN

 

 

 

 

 

 

 

 

 

 

CANCEL

 

 

REW REVERSE PAUSE PLAY FF

 

 

 

 

 

 

SHIFT

 

 

 

 

 

TRACKING

V. LOCK

TIMER SEARCH DISPLAY LOCK CNT RESET

MENU

TIME MODE

 

 

FIELD REV

 

FIELD ADV

+

+

 

 

– S E T +

 

 

 

 

 

 

 

[TIMER] indication

 

[EJECT] button

 

(

) indication

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 

To avoid damage or injury, do not insert your hand or other foreign objects into the cassette loading slot.

For best results, use a T-120 tape.

Auto operate on

 

 

Auto play

When a cassette is loaded, the oprating mode

 

When a cassette with no erasure prevention tab is loaded,

automatically turns on and the (

) cassette indication

playback starts automatically.

appears.

 

 

 

Unloading

 

WARNING

[OFF]

Sets whether or not the buzzer sounds when a warning occurs.

 

 

 

ON

OFF: The buzzer does not sound.

 

BU 22

3

OFF

ON: The buzzer sounds. When the warning is released, the buzzer

 

 

sound stops.

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

IN/OUT

CAMERA SW

[OFF]

Sets the camera switching signal output interval.

 

 

 

1 FIELD

OFF:

No camera switching signal is output.

 

 

 

2 FIELD

1 FIELD: Set to this position to switch cameras every 1 field.

 

iO

1

OFF

2 FIELD: Set to this position to switch cameras every two fields (1

 

 

frame).

 

 

 

1FRD

 

 

 

 

 

 

 

 

 

2FRD

 

 

 

 

 

 

RS-232C

This screen

is shown only when the optional SA-K97U RS-232C board is installed.

 

B. RATE

 

 

 

 

 

 

 

 

600

 

 

 

 

 

 

1200

 

Selects the RS-232C data transfer rate (600 bps, 1200 bps, 2400 bps,

 

 

 

2400

 

4800 bps and 9600 bps).

 

 

 

4800

 

 

 

 

 

 

[9600]

 

 

 

 

 

 

600

 

 

 

 

iO

3

.

 

 

 

 

.

 

 

 

 

 

 

.

 

 

 

 

 

 

9600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5Press the [EJECT] button.

[The cassette is ejected.

The tape reel counter is reset to “0000”.

If the operating mode is not on when the [EJECT] button is pressed, operating mode is automatically switched on and the cassette is ejected. Once the cassette is unloaded, the operating mode turns off again automatically.

If the Timer Recording Standby mode is engaged (TIMER indication is shown on the display), the cassette will not be ejected when the [EJECT] button is pressed.

To unload the cassette, press the [TIMER] button to release the Timer Recording Standby mode, then press the [EJECT] button.

26

27

Image 14
Contents Instructions carefully to ensure Recycled paper Thank you for purchasing this JVC productBefore operating this unit, please read Is made from 100% Best possible performanceInformation Safety PrecautionsOperation Lock RemarqueContents Precautions Major FeaturesPeriodical Maintenance IntroductionDaily Inspection Controls and ConnectorsFront Panel Video cassetteControls and Connectors DisplayRear Panel Connections Connecting to a Camera System Using Sequential SwitcherConnections Time Mode ON-SCREEN/MENU SwitchesConnecting the Rear Panel Input/Output Terminal Connections On-Screen DisplayContents of the main menu items ON-SCREEN/MENU SwitchesDate and Time Setting Main Menu Display1Standard time Alarm Input/Power Loss Data DisplayHour Meter Display Menu Switch Setting Contents of Menu SwitchesAlarm Video Mode Pulse OFFVTR Mode SRI/EXTLoading PreparationCassette Loading/Unloading UnloadingRecording Recording/Playback Speed Mode SelectionSwitch Setting During Recording PreparationRecording Basic Operation Timer RecordingRecording 3 0 0 7STARTStart time blinks and set minute to 00 with the SET + Holiday Timer Recording SettingOn Screen Set the dayCanceling/Changing Timer Recording Program 1To modify timer programsAlarm Recording Connections Sensor RecordingSeries Recording Repeat Recording Non-stop continuous series recordingExternal Timer Recording Recording with External VCR Activation SignalHow to Restore Recording After Power Failure Alarm search/date and time searchPreparation Playback and SPECIAL-EFFECTS PlaybackPlayback and SPECIAL-EFFECTS Playback PlaybackShuttle search reverse and fast-forward playback Alarm Search/Date and Time SearchAlarm search Counter Memory Function Alarm scanRepeat Playback Auto rewindTracking/V. Lock Adjustment TroubleshootingError Indications V. PulseInstallation of the SA-K97U TroubleshootingNo Error Indication Optional SA-K97U RS-232C Interface BoardOptional SA-K97U RS-232C Interface Board SA-K97U SpecificationsSA-K97U RS-232C Protocol & Commands VCR control commands Command descriptionThis section provides technical data for programmers VCR setting commands3rd byte 5th byte Commands for VCR status verification1st/2nd byte 4th byte 6th byteContents of 5th byte BIT 0/1/2/3 Speed Code Others Input data correction/Error cancellationCommands reference chart 4th byteAppendixes AppendixesTape Reel Counter/Tape Remaining Time Table Rear Panel’s Inputs/OutputsSpecifications