9 OPTIONAL SA-K97U RS-232C INTERFACE BOARD
5Date and time setting commands
(1) | DATE SET (8EH) | : Set the current date (month, day, year) for the VCR. After this command (8EH) is sent, input | ||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
| (Example) Oct., 30, 1998 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| TXD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8EH |
| 31H |
|
| 30H |
| 33H |
|
| 30H |
| 39H |
|
| 38H |
|
|
| Time | |||||||
|
| RXD |
| 0AH |
|
| 0AH |
|
| 0AH |
|
| 0AH |
|
| 0AH |
|
| 0AH |
|
| 0AH |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Month |
|
|
| Day |
|
|
| Year |
|
|
|
|
|
| |||||||
(2) | TIME SET (8FH) | : Set the current time (hour, minute, second) for the VCR. |
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
| After this command (8FH) is sent, input |
|
| |||||||||||||||||||||||
|
| (Example) 15 hours, 29 minutes, 59 seconds |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
| TXD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8FH |
| 31H |
|
| 35H |
| 32H |
|
| 39H |
| 35H |
|
| 39H |
|
|
| Time | |||||||
|
| RXD |
| 0AH |
|
| 0AH |
|
| 0AH |
|
| 0AH |
|
| 0AH |
|
| 0AH |
|
| 0AH |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
| Hour |
|
|
| Minute |
|
| Second |
|
|
5Timer programming commands
(1) | PRG/CLK (62H) | : Engages timer programming mode. |
(2) | SHIFT – (64H) | : Selects setting items. |
| SHIFT + (63H) | : Selects setting items. (+) |
(3) | SET – (66H) | : Sets data selected with SHIFT. |
| SET + (65H) | : Sets data selected with SHIFT. |
(4) | CANCEL (67H) | : Cancels program data in timer programming or engages the Cancel Program mode. |
Setting procedure is the same as when using the VCR controls. Be sure to transmit commands 1 byte at a time with “ACK” (0AH) confirmation from the VCR after each transmission.
5
(1) ON SCREEN ON (70H) | : Activates |
ON SCREEN OFF (71H) | : Deactivates |
Setting procedure for the following command (2) is the same as when using the VCR controls. Be sure to transmit commands 1 byte at a time with “ACK” (0AH) confirmation from the VCR after each transmission.
(2)ON SCREEN SELECT (74H): Switches the
POS V+ (73H): Moves the
POS H+ (75H): Moves the
5Other commands
(1) | AL/PL RESET (E1H) | : When transmitted during alarm recording, the recording mode switches back to the previous mode. |
|
| The VCR’s “AL” indication goes off. Transmit again after “AL” indicator goes off to reset the alarm/ |
|
| power loss memory. |
(2) | COUNT RESET (E2H) | : Resets the tape counter to “0000”. |
|
|
|
9 OPTIONAL SA-K97U RS-232C INTERFACE BOARD
3 Commands for VCR status verification
When the command is sent, the VCR returns the corresponding information.
(1) | DATE SENSE (BEH) | : The VCR returns the currently set month, day and year as 6 bytes. Each byte has a value of 30H to |
|
| 39H. 30H corresponds to 0 and 39H to 9. |
|
| (Example: For Oct., 14, 1998, the VCR returns 31H, 30H, 31H, 34H, 39H and 38H.) |
(2) | TIME SENSE (BFH) | : The VCR returns the currently set hour, minute and second as 6 bytes. Each byte has a value of |
|
| 30H to 39H. 30H corresponds to 0 and 39H to 9. |
|
| (Example: For 15:30:45, the VCR returns 31H, 35H, 33H, 30H, 34H and 35H.) |
(3) | COUNT CODE (D0H) | : VCR returns the counter data beginning with the 4th digit from the right in 4 bytes. ASCII codes |
|
| “30H – 39H” correspond with the numbers “0 – 9” (eg: 1234: 31H, 32H, 33H, 34H). |
(4) | DEVICE TYPE (D1H) | : VCR returns the last 4 characters of the |
|
| 39H, 30H, 39H, 30H |
(5) | VTR INQ (FBH) | : Used to make sure that the connected unit is the VCR. The VCR will return “ACK” (0AH). |
(6) | PL/AL COUNT SENSE (D5H) | : VCR will return a total of 6 bytes. The first 3 bytes show the number of alarm inputs in 3 digits and |
|
| the last 3 bytes show the number of power losses in 3 digits. ASCII codes “30H – 39H” correspond |
|
| with the numbers “0 – 9” (eg: 123 alarm inputs and 45 power losses: 31H, 32H, 33H, 30H 34H, |
|
| 35H). |
(7) | HOUR METER SENSE (D2H) | : VCR returns the hour meter data in 5 bytes. (eg: 1234 hours: 31H, 32H, 33H, 34H). |
(8) | TL STATUS SENSE (D6H) | : VCR returns Timelapse mode data in 6 bytes. The contents of each byte are as follows: |
1st/2nd byte
Recording/playback mode
Correspondence of the code and the mode is the same as MODE (7EH) (see page 59).
3rd byte |
| 5th byte |
|
Conditions of each setting | Settings status | ||
BIT | Status when BIT is “1”. | BIT | Status when BIT is “1”. |
0 | Repeat Record mode ON. | 0 | Always 1. |
1 | Power is ON. | 1 | SUMMER TIME is ON. |
2 | POWER ON REC mode is ON. | 2 | Always 0. |
3 | Auto rewind mode is ON. | 3 | Always 0. |
4 | Operation lock is ON.* | 4 | HDR mode is ON. |
5 | Series recording is ON. | 5 | Auto record check function ON. |
6 | Tape end buzzer is ON. | 6 | Always 0. |
7 | Alarm buzzer is ON. | 7 | Always 0. |
|
|
|
|
4th byte |
| 6th byte |
|
Conditions of each setting | Types of warnings | ||
BIT | Status when BIT is “1”. | HEX.Data | Types of warnings |
0 | Alarm recording is in progress. | 0 | No abnormality |
1 | ALARM REC function is ON. | 1 | Loading error |
2 | Not defined. Always 0. | 2 | Unloading error |
3 | Sensor recording is ON. | 3 | Supply reel error |
4 | External recording function is ON. | 4 | Drum error |
5 | V.pulse is ON. | 5 | |
6 | Always 0. | 6 | Capstan error |
7 | Warning buzzer is ON. | 7 | Cassette eject error |
|
| 8 | DEW sensor error. |
|
| 9 | Recording check error |
|
| A | Battery backup error |
|
| B | Input signal error |
|
|
|
|
*Operation with commands from the