JVC SR-9090U Commands for VCR status verification, 1st/2nd byte, 3rd byte 5th byte

Page 31

9 OPTIONAL SA-K97U RS-232C INTERFACE BOARD

5Date and time setting commands

(1)

DATE SET (8EH)

: Set the current date (month, day, year) for the VCR. After this command (8EH) is sent, input

 

 

 

1-byte numerical data (30H — 39H).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Example) Oct., 30, 1998

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TXD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8EH

 

31H

 

 

30H

 

33H

 

 

30H

 

39H

 

 

38H

 

 

 

Time

 

 

RXD

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Month

 

 

 

Day

 

 

 

Year

 

 

 

 

 

 

(2)

TIME SET (8FH)

: Set the current time (hour, minute, second) for the VCR.

 

 

 

 

 

 

 

 

 

 

 

 

 

After this command (8FH) is sent, input 1-byte numerical data (30H — 39H).

 

 

 

 

(Example) 15 hours, 29 minutes, 59 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TXD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8FH

 

31H

 

 

35H

 

32H

 

 

39H

 

35H

 

 

39H

 

 

 

Time

 

 

RXD

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

0AH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hour

 

 

 

Minute

 

 

Second

 

 

5Timer programming commands

(1)

PRG/CLK (62H)

: Engages timer programming mode.

(2)

SHIFT – (64H)

: Selects setting items. (–)

 

SHIFT + (63H)

: Selects setting items. (+)

(3)

SET – (66H)

: Sets data selected with SHIFT.

 

SET + (65H)

: Sets data selected with SHIFT.

(4)

CANCEL (67H)

: Cancels program data in timer programming or engages the Cancel Program mode.

Setting procedure is the same as when using the VCR controls. Be sure to transmit commands 1 byte at a time with “ACK” (0AH) confirmation from the VCR after each transmission.

5 On-screen setting command

(1) ON SCREEN ON (70H)

: Activates on-screen indication.

ON SCREEN OFF (71H)

: Deactivates on-screen indication.

Setting procedure for the following command (2) is the same as when using the VCR controls. Be sure to transmit commands 1 byte at a time with “ACK” (0AH) confirmation from the VCR after each transmission.

(2)ON SCREEN SELECT (74H): Switches the on-screen display items.

POS V+ (73H): Moves the on-screen indication in the vertical direction.

POS H+ (75H): Moves the on-screen indication in the horizontal direction.

5Other commands

(1)

AL/PL RESET (E1H)

: When transmitted during alarm recording, the recording mode switches back to the previous mode.

 

 

The VCR’s “AL” indication goes off. Transmit again after “AL” indicator goes off to reset the alarm/

 

 

power loss memory.

(2)

COUNT RESET (E2H)

: Resets the tape counter to “0000”.

 

 

 

9 OPTIONAL SA-K97U RS-232C INTERFACE BOARD

3 Commands for VCR status verification

When the command is sent, the VCR returns the corresponding information.

(1)

DATE SENSE (BEH)

: The VCR returns the currently set month, day and year as 6 bytes. Each byte has a value of 30H to

 

 

39H. 30H corresponds to 0 and 39H to 9.

 

 

(Example: For Oct., 14, 1998, the VCR returns 31H, 30H, 31H, 34H, 39H and 38H.)

(2)

TIME SENSE (BFH)

: The VCR returns the currently set hour, minute and second as 6 bytes. Each byte has a value of

 

 

30H to 39H. 30H corresponds to 0 and 39H to 9.

 

 

(Example: For 15:30:45, the VCR returns 31H, 35H, 33H, 30H, 34H and 35H.)

(3)

COUNT CODE (D0H)

: VCR returns the counter data beginning with the 4th digit from the right in 4 bytes. ASCII codes

 

 

“30H – 39H” correspond with the numbers “0 – 9” (eg: 1234: 31H, 32H, 33H, 34H).

(4)

DEVICE TYPE (D1H)

: VCR returns the last 4 characters of the SR-9090 model name in ASCII code.

 

 

39H, 30H, 39H, 30H

(5)

VTR INQ (FBH)

: Used to make sure that the connected unit is the VCR. The VCR will return “ACK” (0AH).

(6)

PL/AL COUNT SENSE (D5H)

: VCR will return a total of 6 bytes. The first 3 bytes show the number of alarm inputs in 3 digits and

 

 

the last 3 bytes show the number of power losses in 3 digits. ASCII codes “30H – 39H” correspond

 

 

with the numbers “0 – 9” (eg: 123 alarm inputs and 45 power losses: 31H, 32H, 33H, 30H 34H,

 

 

35H).

(7)

HOUR METER SENSE (D2H)

: VCR returns the hour meter data in 5 bytes. (eg: 1234 hours: 31H, 32H, 33H, 34H).

(8)

TL STATUS SENSE (D6H)

: VCR returns Timelapse mode data in 6 bytes. The contents of each byte are as follows:

1st/2nd byte

Recording/playback mode

Correspondence of the code and the mode is the same as MODE (7EH) (see page 59).

3rd byte

 

5th byte

 

Conditions of each setting

Settings status

BIT

Status when BIT is “1”.

BIT

Status when BIT is “1”.

0

Repeat Record mode ON.

0

Always 1.

1

Power is ON.

1

SUMMER TIME is ON.

2

POWER ON REC mode is ON.

2

Always 0.

3

Auto rewind mode is ON.

3

Always 0.

4

Operation lock is ON.*

4

HDR mode is ON.

5

Series recording is ON.

5

Auto record check function ON.

6

Tape end buzzer is ON.

6

Always 0.

7

Alarm buzzer is ON.

7

Always 0.

 

 

 

 

4th byte

 

6th byte

 

Conditions of each setting

Types of warnings

BIT

Status when BIT is “1”.

HEX.Data

Types of warnings

0

Alarm recording is in progress.

0

No abnormality

1

ALARM REC function is ON.

1

Loading error

2

Not defined. Always 0.

2

Unloading error

3

Sensor recording is ON.

3

Supply reel error

4

External recording function is ON.

4

Drum error

5

V.pulse is ON.

5

Take-up reel error

6

Always 0.

6

Capstan error

7

Warning buzzer is ON.

7

Cassette eject error

 

 

8

DEW sensor error.

 

 

9

Recording check error

 

 

A

Battery backup error

 

 

B

Input signal error

 

 

 

 

*Operation with commands from the RS-232C is accepted even in the Operation Lock mode.

60

61

Image 31
Contents Best possible performance Thank you for purchasing this JVC productBefore operating this unit, please read Is made from 100% Instructions carefully to ensure Recycled paperRemarque Safety PrecautionsOperation Lock InformationContents Introduction Major FeaturesPeriodical Maintenance PrecautionsVideo cassette Controls and ConnectorsFront Panel Daily InspectionDisplay Controls and ConnectorsRear Panel Connections Connecting to a Camera System Using Sequential SwitcherConnections On-Screen Display ON-SCREEN/MENU SwitchesConnecting the Rear Panel Input/Output Terminal Connections Time ModeMain Menu Display ON-SCREEN/MENU SwitchesDate and Time Setting Contents of the main menu itemsHour Meter Display Alarm Input/Power Loss Data Display1Standard time Contents of Menu Switches Menu Switch SettingSRI/EXT Video Mode Pulse OFFVTR Mode AlarmUnloading PreparationCassette Loading/Unloading LoadingPreparation Recording/Playback Speed Mode SelectionSwitch Setting During Recording RecordingRecording Timer RecordingRecording Basic Operation 7START 3 0 0Set the day Holiday Timer Recording SettingOn Screen Start time blinks and set minute to 00 with the SET +1To modify timer programs Canceling/Changing Timer Recording ProgramAlarm Recording Series Recording Sensor RecordingConnections Non-stop continuous series recording Repeat RecordingAlarm search/date and time search Recording with External VCR Activation SignalHow to Restore Recording After Power Failure External Timer RecordingPlayback Playback and SPECIAL-EFFECTS PlaybackPlayback and SPECIAL-EFFECTS Playback PreparationAlarm search Alarm Search/Date and Time SearchShuttle search reverse and fast-forward playback Auto rewind Alarm scanRepeat Playback Counter Memory FunctionV. Pulse TroubleshootingError Indications Tracking/V. Lock AdjustmentOptional SA-K97U RS-232C Interface Board TroubleshootingNo Error Indication Installation of the SA-K97USA-K97U RS-232C Protocol & Commands SA-K97U SpecificationsOptional SA-K97U RS-232C Interface Board VCR setting commands Command descriptionThis section provides technical data for programmers VCR control commands4th byte 6th byte Commands for VCR status verification1st/2nd byte 3rd byte 5th byte4th byte Others Input data correction/Error cancellationCommands reference chart Contents of 5th byte BIT 0/1/2/3 Speed CodeRear Panel’s Inputs/Outputs AppendixesTape Reel Counter/Tape Remaining Time Table AppendixesSpecifications