Test Run
After all preparation steps have been completed, the machine and its safety features must be tested to ensure correct operation. If you discover a problem with the operation of the machine or its safety components, do not operate it further until you have resolved the problem.
If you discover a problem with the operation of the machine or its safety components, do not oper- ate it further until you have resolved the problem. Refer to the Troubleshooting section on Page 49 for solutions to common problems that may occur with all mills. If you need additional help, contact our Tech Support at (570)
Mill Test Run
1.Read and follow the safety instructions at the beginning of the manual, take required safety precautions, and make sure the machine is set up and adjusted properly
2.Clear away all tools and objects used during assembly and preparation.
3.Make sure that the mill is properly lubricated (refer to the Lubrication section on Page 44 for specific details).
4.set the spindle speed to the low range (refer to Page 33 or 35 for detailed instructions).
5.Move the downfeed selector to the manual (forward) position so that the spindle does not downfeed during this test (refer to the Downfeed Operations section on Page 36 for detailed instructions).
6.Connect the mill to the power source speci- fied in the POWER SUPPLY section on Page 14.
Model G0747/G0748 (Mfg. Since 8/12)
7.use the spindle switch to turn the mill ON.
For Model G0747: Turn the spindle switch to the FLOW (forward low) position, as shown in Figure 14.