Multi-Tech Systems MT2834ZDX $H n Help Screens, Inquire Product Codes, $J n Display Parity Bit

Page 12

Chapter 3 – AT Commands, S-Registers, and Results Codes

Command:

$Hn Help Screens

Values:

n = 1, 2, or 3

Default:

None

Description:

$H1 Display Help Screen #1.

 

$H2 Display Help Screen #2.

 

$H3 Display Help Screen #3.

Command:

In

Inquire Product Codes

Values:

n = 0, 1, or 2

Default:

None

Description:

I0

Display modem ID number.

 

I1

Display firmware version number.

 

I2

Display modem description.

Command:

$Jn Display Parity Bit

Values:

n = 0, 1

Default:

0

Description:

The $J command allows the parity bit to be seen when XON/OFF flow control is enabled (see the

 

&E command.)

 

$J0 disables the display of the parity bit to be seen when XON/XOFF flow control is enabled.

 

$J1 enables the display of the parity bit to be seen when XON/XOFF flow control is enabled.

Command:

Ln

List Commands

Values:

n = 0, 5–8

Default:

None

Description:

L List stored telephone numbers.

 

L5 List current operating parameters.

 

L6 List current S-register values.

 

L7 List additional current operating parameters.

 

L8 List DSP code version number, processor speed, and online diagnostic parameters.

 

L9 List signal strength information.

 

L10 List signal to noise ratio information (SNR).

 

L11 List noise information.

 

Note: For L9, L10, and L11, you must first type +++AT<CR> (online escape command while

 

maintaining command mode), then type the command prefixed by an AT (e.g., ATL10).

Command:

#Ln V.42 Mode Selection in Originate Mode

Values:

n = 0, 1, 2, or 3

Default:

0

 

Description:

#L0 Modems negotiate V.42 mode.

 

#L1 MNP on & LAP-M off.

 

#L2 LAP-M on & MNP off.

 

#L3 Disable detection phase and go directly to LAP-M.

Command:

Mn

Modem Speaker Control

Values:

n = 0, 1, 2, or 3

Default:

1

 

Description:

M0 Speaker always off.

 

M1 Speaker on until carrier signal detected.

 

M2 Speaker always on.

 

M3 Speaker on during dialing, off during handshaking.

Multi-Tech Systems, Inc. MT2834ZDX User's Guide

12

Image 12
Contents MT2834ZDX-Series External Data/Fax Modem Users Guide User Guide MT2834ZDX-Series S000309A Rev. a Copyright Contents Introduction Installation Safety WarningsFeatures Getting StartedModem Installation Attach the Self-Adhesive FeetConnect the Modem to Your System Install the Modem Driver Install Data Communications SoftwareRemoving Your Old Modem from Windows Speed Indicator Blink Rates OperationFront Panel AT Commands, S-Registers Result Codes AT Commands$BAn Baud Adjust DCn AT Command ControlCarrier Detect Control CDn Cleardown at DisconnectEn Echo Command Mode Characters En V.42 Error Correction ModesEn Non-Error Correction Mode Flow Control DPn Read Line Probe Data$En V.42 Error Correction at 300 bps Load Default Configurations$Fn Enable/Disable Auto-Reliable Fallback Character Fn Echo Frequency Canceller Offset CompensationList Commands #L n V.42 Mode Selection in Originate Mode$H n Help Screens Inquire Product CodesResult Codes Enable/Disable $MBn Modem Baud RateNd Dial a Stored Number NdNe. .. Number LinkingRn Clear to Send Control RAn Asymmetrical Bit RateRDn Square Wave Ring Detect RFn CTS/RTS Interaction ControlTn Respond to Remote Digital Loopback Signal SFn DSR/CD Interaction Control$SBn Serial Port Baud Rate Tone-DialWn Store Configuration Modem ResetReturn to Command Mode Xn Result Codes and Call Progress SelectionAtcr Remote Configuration Escape Sequence +++ATCR Escape CodeBreakatcr Escape Sequence Register Unit Range Default Description RegistersResult Codes Terse VerboseTroubleshooting None of the LEDs Light When the Modem Is OnModem Dials But Cannot Connect Modem Disconnects While Online There Are Garbage Characters on the Monitor Appendix a Regulatory Compliance Regulatory ComplianceCFR Part 15 Regulation CFR Part 68 Telecom Current Requirements for Label Content and Format USAAAEQ##TxxxxRegulatory Requirements for Canada Industry Canada IC XXXXXX-ZZZZZZZZ WhereAppendix B Technical Specifications Command Buffer 60 charactersManual Control Power switch Transmit Level -13 dBm Frequency Stability +/-0.01%Appendix C Warranty and Service WarrantyOnline Warranty Registration About the Internet Index AtcrModem driver installation