Multi-Tech Systems MT2834ZDX manual Rn Clear to Send Control, RAn Asymmetrical Bit Rate

Page 14

 

 

Chapter 3 – AT Commands, S-Registers, and Results Codes

 

 

Command:

&Rn Clear to Send Control

Values:

n = 0, 1, or 2

Default:

1

 

Description:

&R0 Let CTS state follow RTS state when on line.

 

&R1 Force CTS high (on).

 

&R2 Let CTS drop on disconnect for time set by S24, then go high again.

Command:

&RAn

Asymmetrical Bit Rate

Values:

n = 0 or 1

Default:

0

 

Description:

&RA0 Enable asymmetrical bit rate in V.34 mode.

 

&RA1 Disable asymmetrical bit rate in V.34 mode.

Command:

&RDn Square Wave Ring Detect

Values:

n = 0 or 1

Default:

1

 

Description:

&RD0 Modem detects only sine wave rings.

 

&RD1 Modem detects both sine and square wave rings.

Command:

&RFn

CTS/RTS Interaction Control

Values:

n = 0 or 1

Default:

1

 

Description:

&RF0 Let CTS follow RTS.

 

&RF1 Let CTS act independently (use with &R).

Command:

&RN

Rate Negotiation

Values:

n/a

 

Description:

Forces the modem to perform a rate renegotiation while on line. You must escape to command

 

mode to issue this command.

Command:

&RP

Immediate Line Probe

Values:

n/a

 

Description:

Initiates a retrain that makes the processor read line probe information if %DP1 is selected. Valid

 

only when on line in V.34 mode.

Command:

&RR

Immediate Retrain

Values:

n/a

 

Description:

Forces the modem to perform an immediate retrain while on line. You must escape to command

 

mode to issue this command.

Command:

$Rn

Retransmit Count

Values:

n = 0 or 1

Default:

0

 

Description:

$R0 Disconnect after 50 retransmits of a data block.

 

$R1 Do not disconnect after 50 retransmits.

Command:

Sr=n

Set Register Value

Values:

r = S-register number; n varies

Default:

None

 

Description:

Set value of register S r to value of n, where n is entered in decimal format.

Command:

Sr?

Read Register Value

Values:

r = S-register number

Default:

None

 

Description:

Read value of register S r and display value in 3- digit decimal form.

Command:

&Sn

Data Set Ready Control

Values:

n = 0, 1, or 2

Default:

1

 

Description:

&S0 Force DSR high (on).

 

&S1 Let DSR follow CD.

 

&S2 DSR drops on disconnect, then goes high again. (Used by some CBX phone systems.)

Multi-Tech Systems, Inc. MT2834ZDX User's Guide

14

Image 14
Contents MT2834ZDX-Series External Data/Fax Modem Users Guide User Guide MT2834ZDX-Series S000309A Rev. a Copyright Contents Features Introduction InstallationSafety Warnings Getting StartedConnect the Modem to Your System Modem InstallationAttach the Self-Adhesive Feet Removing Your Old Modem from Windows Install the Modem DriverInstall Data Communications Software Front Panel Speed Indicator Blink RatesOperation AT Commands, S-Registers Result Codes AT CommandsCarrier Detect Control $BAn Baud AdjustDCn AT Command Control CDn Cleardown at DisconnectEn Non-Error Correction Mode Flow Control En Echo Command Mode CharactersEn V.42 Error Correction Modes DPn Read Line Probe Data$Fn Enable/Disable Auto-Reliable Fallback Character $En V.42 Error Correction at 300 bpsLoad Default Configurations Fn Echo Frequency Canceller Offset Compensation$H n Help Screens List Commands#L n V.42 Mode Selection in Originate Mode Inquire Product CodesNd Dial a Stored Number Result Codes Enable/Disable$MBn Modem Baud Rate NdNe. .. Number LinkingRDn Square Wave Ring Detect Rn Clear to Send ControlRAn Asymmetrical Bit Rate RFn CTS/RTS Interaction Control$SBn Serial Port Baud Rate Tn Respond to Remote Digital Loopback SignalSFn DSR/CD Interaction Control Tone-DialReturn to Command Mode Wn Store ConfigurationModem Reset Xn Result Codes and Call Progress SelectionBreakatcr Escape Sequence Atcr Remote Configuration Escape Sequence+++ATCR Escape Code Register Unit Range Default Description RegistersResult Codes Terse VerboseTroubleshooting None of the LEDs Light When the Modem Is OnModem Dials But Cannot Connect Modem Disconnects While Online There Are Garbage Characters on the Monitor CFR Part 15 Regulation Appendix a Regulatory ComplianceRegulatory Compliance CFR Part 68 Telecom Current Requirements for Label Content and Format USAAAEQ##TxxxxRegulatory Requirements for Canada Industry Canada IC XXXXXX-ZZZZZZZZ WhereManual Control Power switch Appendix B Technical SpecificationsCommand Buffer 60 characters Transmit Level -13 dBm Frequency Stability +/-0.01%Appendix C Warranty and Service WarrantyOnline Warranty Registration About the Internet Index AtcrModem driver installation