Multi-Tech Systems MT2834ZDX $En V.42 Error Correction at 300 bps, $EBn Asynchronous Word Length

Page 11

 

 

Chapter 3 – AT Commands, S-Registers, and Results Codes

 

 

Command:

$En V.42 Error Correction at 300 bps

Values:

n = 0 or 1

Default:

0

 

Description:

$E0 V.42 error correction at 300 bps disabled.

 

$E1 V.42 error correction at 300 bps enabled.

Command:

$EBn

Asynchronous Word Length

Values:

n = 0 or 1

Default:

0

 

Description:

$EB0 10-bit mode enabled.

 

$EB1 11-bit mode enabled.

Command:

%En

Escape Sequence Options

Values:

n = 0–5

Defaults:

1 and 4

Description:

%E0 Modem won’t escape.

 

%E1 +++AT<CR> method.

 

%E2 <BREAK>AT<CR> method.

 

%E3 Both +++AT<CR> and <BREAK>AT<CR> methods.

 

%E4 No OK response to +++AT<CR>.

 

%E5 OK response to +++AT<CR>.

Command:

&Fn

Load Default Configurations

Values:

n = 0, 8, or 9

Default:

8

 

Description:

&F0 Load factory default values from ROM if &F8 was previously stored; load user default values

 

from non-volatile memory if &F9 was previously stored.

 

&F8 Read factory default values when &F is issued (effective only if you store &F8 using &W0).

 

&F9 Read values stored in non-volatile memory when &F is issued (effective only if you store &F9

 

using &W0).

Command:

$Fn Enable/Disable Auto-Reliable Fallback Character

Values:

n = 0 or 1

Default:

0

 

Description:

$F0 Do not fall back to non-error correction mode connect if <CR> is received during handshake.

 

$F1 Fall back to non-error correction mode connect if <CR> is received during handshake.

Command:

%Fn Echo Frequency Canceller Offset Compensation

Values:

n = 0 or 1

Default:

0

 

Description:

%F0 Disable echo canceller frequency offset compensation.

 

%F1 Enable echo canceller frequency offset compensation.

Command:

#Fn Fallback Modes When Online

Values:

n = 0, 1, or 2

Default:

2

 

Description:

#F0 No fallback when on line.

 

#F1 Fallback decrementally from maximum speed to 4800 bps as line conditions deteriorate.

 

#F2 Fallback decrementally to 4800 bps; fall forward when line conditions improve.

Command:

&Gn

Guard Tones

Values:

n = 0, 1, or 2

Default:

0

 

Description:

&G0 Turn off ITU-T guard tones.

 

&G1 Turn on ITU-T 550 Hz guard tone.

 

&G2 Turn on ITU-T 1800 Hz guard tone.

 

Note: The ZDXK is locked to the ITU-T 1800 Hz guard tone (&G2).

Command:

Hn On Hook/Off Hook

Values:

n = 0 or 1

Default:

None

 

Description:

H0 Go on hook (hang up).

 

H1 Go off hook.

Multi-Tech Systems, Inc. MT2834ZDX User's Guide

11

Image 11
Contents MT2834ZDX-Series External Data/Fax Modem Users Guide User Guide MT2834ZDX-Series S000309A Rev. a Copyright Contents Getting Started Introduction InstallationSafety Warnings FeaturesConnect the Modem to Your System Modem InstallationAttach the Self-Adhesive Feet Removing Your Old Modem from Windows Install the Modem DriverInstall Data Communications Software Front Panel Speed Indicator Blink RatesOperation AT Commands AT Commands, S-Registers Result CodesCDn Cleardown at Disconnect $BAn Baud AdjustDCn AT Command Control Carrier Detect ControlDPn Read Line Probe Data En Echo Command Mode CharactersEn V.42 Error Correction Modes En Non-Error Correction Mode Flow ControlFn Echo Frequency Canceller Offset Compensation $En V.42 Error Correction at 300 bpsLoad Default Configurations $Fn Enable/Disable Auto-Reliable Fallback CharacterInquire Product Codes List Commands#L n V.42 Mode Selection in Originate Mode $H n Help ScreensNdNe. .. Number Linking Result Codes Enable/Disable$MBn Modem Baud Rate Nd Dial a Stored NumberRFn CTS/RTS Interaction Control Rn Clear to Send ControlRAn Asymmetrical Bit Rate RDn Square Wave Ring DetectTone-Dial Tn Respond to Remote Digital Loopback SignalSFn DSR/CD Interaction Control $SBn Serial Port Baud RateXn Result Codes and Call Progress Selection Wn Store ConfigurationModem Reset Return to Command ModeBreakatcr Escape Sequence Atcr Remote Configuration Escape Sequence+++ATCR Escape Code Registers Register Unit Range Default DescriptionTerse Verbose Result CodesNone of the LEDs Light When the Modem Is On TroubleshootingModem Dials But Cannot Connect Modem Disconnects While Online There Are Garbage Characters on the Monitor CFR Part 15 Regulation Appendix a Regulatory ComplianceRegulatory Compliance CFR Part 68 Telecom USAAAEQ##Txxxx Current Requirements for Label Content and FormatRegulatory Requirements for Canada IC XXXXXX-ZZZZZZZZ Where Industry CanadaTransmit Level -13 dBm Frequency Stability +/-0.01% Appendix B Technical SpecificationsCommand Buffer 60 characters Manual Control Power switchWarranty Appendix C Warranty and ServiceOnline Warranty Registration About the Internet Atcr IndexModem driver installation