Extron electronic WMK 100 Run cables, Cable the switcher, 3A. If running cable behind the walls

Page 3

3. Run cables

Run signal cables from the proposed PoleVault input wall plates, control device location, and the speakers to the WMK 100 location. Cables can be routed behind the walls, or through a surface raceway (e.g., Wiremold 700 or 2400 series) directly to the WMK 100.

3A. If running cable behind the walls:

i.Run all the cables from the various locations to the WMK and through the access hole.

3B. If using a surface raceway:

i.Attach the WMK cover to the base plate, then identify and mark the most suitable raceway entrance to the WMK 100.

ii.Run the raceway from the signal source, speaker, and display locations to the marked raceway entrance at the WMK.

iiiRemove the WMK cover, and remove the desired knockout.

iv.Attach the raceway to the wall and run cables from the sources and outputs through the raceway to the WMK.

4.Cable the switcher

700

2400

Raceway Option

Signal Cable Access

Cutout Option

Figure 6 — Cabling run options

a.Connect the cables from the PoleVault transmitters, control device

(MediaLink® Controller), speakers, and optional accessories (VoiceLift, Page Sensor Kit) to the rear ports of the switcher (see below). Refer to the PVS 305SA Setup Guide for additional details.

NIf using a device other than a PVS 305SA (e.g., PVS 204SA Plus), refer to that device's user manual for details.

b.Run VGA and composite video cables from the switcher to the output display device through the wall or where fitted, the raceway.

c.Connect the power supply to the switcher and plug it in to the electrical outlet.

NIf the electrical outlet is outside the WMK, pass the IEC power cable out through one of the raceway knockouts.

PRELIMINARY

 

RGB signal input

 

 

 

 

(2 CAT 5 cables, A and B

 

 

 

 

with RJ-45 connectors)

 

 

 

AUDIO

 

 

 

 

 

IN OUT

 

 

 

 

 

COMPUTER IN

RGB #1B

A

 

 

 

MONITOR OUT

 

 

 

 

RGB #1A

 

 

 

 

N15779

 

 

 

 

PVT RGB D Plus

1A

2A RGB

3A RGB

4A RGB

 

 

 

 

 

 

I

 

 

 

Power

POWER

N

 

 

 

P

 

 

 

Connector

U

 

 

 

T

 

 

 

 

K

S

 

 

 

External

1B RGB

2B RGB

3B RGB

4BRGBB

12V

Power Supply

3/VIDEO

4/VIDEO

5A MAX

 

 

 

 

 

 

(12 VDC, 5 A max.)

 

 

 

 

B

 

 

 

 

 

 

 

Audio output

 

 

Line out output

 

 

 

to speakers

 

 

 

 

 

 

 

 

 

 

 

 

(audio)

 

 

 

 

 

Wire Color PVS Terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(left and right)

 

 

 

 

 

 

 

 

 

Red

Positive (+)

 

 

 

 

 

 

 

 

 

Black

Negative (-)

 

 

 

 

G

 

F

 

 

 

 

 

17TT

 

LINE OUT

AMPLIFIED AUDIO OUT

 

 

 

US

 

 

DO NOT

 

 

 

 

 

®

AUDIO/VIDEO

 

 

GROUND

 

 

 

 

 

LISTED

 

APPARATUS

 

 

OR SHORT

 

 

2/4/8

 

 

 

 

 

 

 

SPEAKER

 

 

Ohms

 

 

OUTPUTS

 

VOICELIFT

L

R

OUTPUTS

 

 

 

 

 

 

RECEIVER

CLASS 2 WIRING

L

R

 

 

RGB

VIDEO

 

 

 

 

 

L

R

10V

50mA

CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tx Rx IR

12V

 

 

 

 

 

 

 

 

 

 

 

AUX AUDIO

PAGING

 

 

 

RS-232 MLC/IR

 

INPUT 5

SENSOR VOL/MUTE

 

 

 

D E I C J H

RS-232 Control

Composite video input

 

(CAT 5 cable with

VGA

RJ-45 connector)

Connector

 

#3VIDEO

RGB output

to display

VIDEO IN

AUDIO IN

L

R

S

G

IR OUT

PVT CV D

Cabling the switcher

RCA

Paging

 

 

 

Sensor

 

 

 

Connector

 

 

 

 

 

 

 

 

Aux Audio

 

 

 

 

Input 5

 

 

 

 

VoiceLift

 

 

 

 

Receiver

 

+12 VDC

 

Composite

 

 

Ground (

)

 

 

Ground (

)

video output

 

 

Receive (Rx) B

 

 

Transmit (Tx) A

to display

MLC

Wire Colors

PVS Switcher

 

 

A (Rx)

White

A (Tx)

 

 

B (Tx)

Violet

B (Rx)

 

 

Ground

Drain Wire

D (Ground)

 

 

Ground

Black

D (Ground)

 

 

12V In

Red

E +12 V

 

DISPLAY

ON

OFF

VOLUME

CONFIG

VCR 1

DVD

2

PC 3

4

MLC 104 IP PLUS

3

Image 3
Contents Proceed to Step Mount the base plateMaximum load for the WMK 100 is 15 lbs 7 kg 1A. To mount the WMK 100 onto masonry wallsMount the switcher and power supply If using toggle assemblies see for installation method1B. To mount the WMK 100 onto a non-masonry wall 3A. If running cable behind the walls Cable the switcher3B. If using a surface raceway Run cablesSpecifications are subject to change without notice Final installation