Dell SC1435 Incorrect Time or Date settings, Faulty system battery, If the problem persists

Page 21

Table 1-6. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Time-of-day not set -

Incorrect Time or Date settings;

Check the Time and Date settings. See

please run SETUP program

faulty system battery.

"Using the System Setup Program" on

 

 

page 23. If the problem persists,

 

 

replace the system battery. See "System

 

 

Battery" on page 59.

 

 

 

Timer chip counter 2

Faulty system board.

See "Getting Help" on page 95.

failed

 

 

 

 

 

Unsupported CPU

Microprocessor(s) is not supported

Install a supported microprocessor or

combination

by the system.

microprocessor combination. See

Unsupported CPU stepping

 

"Processors" on page 50.

 

 

detected

 

 

Utility partition not

The <F10> key was pressed during

available

POST, but no utility partition exists

 

on the boot hard drive.

Create a utility partition on the boot hard drive. See the CDs that came with your system.

Warning: DIMM n and n are faulty and disabled. Total memory size is reduced!

Faulty or improperly seated memory

See "Troubleshooting System Memory"

module(s).

on page 76.

Warning! No microcode

Microcode update failed.

Update the BIOS firmware. See

update loaded for

 

"Getting Help" on page 95.

processor n

 

 

 

 

 

Warning: One or more

Faulty or improperly seated memory

See "Troubleshooting System Memory"

faulty DIMMs found on

module(s) used by CPUn.

on page 76.

CPUn

 

 

Warning: The installed

Invalid memory configuration. The

memory configuration is

system will run but with reduced

not optimal. For more

functionality.

information on valid

 

memory configurations,

 

please see the system

 

documentation on the

 

technical support web

 

site.

 

Ensure that the memory modules are installed in a valid configuration. See "Memory Module Installation Guidelines" on page 46. If the problem persists, see "Troubleshooting System Memory" on page 76.

Write fault

Write fault on selected drive

Faulty diskette, optical/diskette drive assembly, hard drive, or hard- drive subsystem.

See "Troubleshooting a USB Device" on page 71, "Troubleshooting an Optical Drive" on page 78, or "Troubleshooting a Hard Drive" on page 78.

NOTE: For the full name of an abbreviation or acronym used in this table, see the "Glossary" on page 121.

About Your System

21

Image 21
Contents W . d e l l . c o m s u p p o r t . d e l l . c o m Dell PowerEdge SC1435 SystemsAugust HJ362 Contents Baseboard Management Controller Configuration Memory Module Installation GuidelinesRemoving and Replacing the Front Bezel Control Panel Assembly Service-Only Procedure Troubleshooting a SAS RAID Controller Card Troubleshooting System Cooling Problems121 Returning Items for Warranty Repair or Credit129 Dell Enterprise Training and CertificationContents About Your System Other Information You May NeedAccessing System Features During Startup Front-Panel Features and Indicators System can cause the indicator to flash blue to Panel display error codes during system startupProblem USB connectorsBack-Panel Features and Indicators Power Indicator CodesConnecting External Devices Diagnostics Indicator Codes NIC Indicator CodesPower Button Indicators Indicator FunctionOther failure Troubleshooting a Hard Drive onSystem Messages Cable. See Troubleshooting a USB System Setup program Correct the settings. See UsingInvalid memory configuration Retry Remote ConfigurationAction to resolve the problem Carry out the command Specific information. NoteFaulty keyboard controller faulty See Getting Help on Manufacturing modeOn page 23. If necessary, install System Setup program, or noFaulty system board See Getting Help on No operating system on diskette Use a bootable disketteOr faulty Appropriate drives installed in yourFaulty diskette or hard drive Operating system cannot readFaulty system battery Incorrect Time or Date settings23. If the problem persists On the boot hard driveAlert Messages Diagnostics MessagesEntering the System Setup Program Responding to Error MessagesUsing the System Setup Program System Setup Options Using the System Setup ProgramMain Screen CPU Information Screen on Boot Sequence Retry System Setup Program Options Description Boot SequenceTo boot after 30 seconds Using the Setup Password on page 32 for more informationCPU Information Screen Memory Information ScreenIntegrated Devices Screen System Security Screen Using the System Password System and Setup Password FeaturesLast default RestoredUsing the System Setup Program Using the Setup Password Disabling a Forgotten Password Baseboard Management Controller ConfigurationSee Disabling a Forgotten Password on BMC Setup Module Options Entering the BMC Setup ModuleRecommended Tools Installing System ComponentsInside the System Removing the Bezel Key lock Removing and Replacing the Front BezelOpening the System Opening and Closing the SystemCooling Shroud Closing the SystemRemoving the Cooling Shroud Cooling Fan Modules Replacing the Cooling ShroudRemoving a Cooling Fan Module Cooling fan modules Replacing a Cooling Fan ModuleRemoving the Power Supply Power SupplyRemoving and Installing a Power Supply Installing the Power SupplyExpansion Cards Installing an Expansion CardExpansion card Expansion-card latch Removing an Expansion CardMemory Module Installation Guidelines Sample Memory ConfigurationsSystem Memory Single-Processor Memory Configurations Total Dual-Processor Memory Configurations Total512 MB 12 GB 16 GB Installing System Components MemoryNon-Optimal Memory Configurations Installing Memory ModulesEjectors Installing System Components Removing Memory Modules Removing a Processor ProcessorsCover Installing and Removing the Heat Sink Heat sinkAdding second processor Processor ZIF socket Socket key Installing a ProcessorInstalling System Components Installing the Optical Drive in the System Optical DriveRemoving the Optical Drive from the System Removing the Optical Drive from the Drive Tray Hard DrivesInterposer board TabsInstalling a Hard Drive Optional SAS RAID ControllerBefore You Begin Hard drive bay Configuring the Boot DeviceRiser board alignment pins Installing System Components Expansion-Card RiserRemoving an Expansion-Card Riser Installing an Expansion-CardRiser System BatteryReplacing the System Battery System battery is a 3.0-volt V, coin-cell batteryConnector Removing the Control Panel Control Panel Assembly Service-Only ProcedureInstalling the Control Panel Removing the System Board System Board Service-Only ProcedureSystem-board tray Installing a System BoardInstalling System Components Installing System Components CD drive activity indicator Safety First-For You and Your SystemStart-Up Routine Lights on the system front panelChecking Basic Power Problems Troubleshooting IRQ Assignment ConflictsChecking the Equipment Troubleshooting the Video Subsystem Troubleshooting External ConnectionsMonitor is not working properly Video memory is faulty Math coprocessorTroubleshooting Basic I/O Functions Troubleshooting the KeyboardTroubleshooting the Mouse Troubleshooting a USB Device Troubleshooting a Serial I/O DeviceTroubleshooting a Wet System Troubleshooting a NICNIC cannot communicate with network Liquid spilled on the system Excessive humiditySystem was dropped or damaged Troubleshooting a Damaged SystemTroubleshooting the System Battery Troubleshooting the Power SupplyPower button indicator is off Troubleshooting a Fan Troubleshooting System Cooling ProblemsTroubleshooting System Memory Troubleshooting Your System Troubleshooting an Optical Drive Troubleshooting a Hard DriveAction Troubleshooting Your System Troubleshooting a SAS RAID Controller Card Troubleshooting an Expansion Card Action Troubleshooting the Microprocessors Troubleshooting Your System Troubleshooting Your System Using Dell PowerEdge Diagnostics System Diagnostics FeaturesRunning the System Diagnostics When to Use the System Diagnostics Running the System DiagnosticsSystem Diagnostics Testing Options Selecting Devices for Testing Using the Custom Test OptionsSelecting Diagnostics Options Viewing Information and ResultsRunning the System Diagnostics System Board Jumpers System Board Jumpers Jumpers and ConnectorsNvrmclr System Board Jumper Settings Jumper SettingDescriptionJumpers and Connectors System Board Connectors Jumpers and Connectors System Board ConnectorsRiser board connector System Board Connectors DescriptionMemory module connector, slot Microprocessor 2 connectorPCIe Riser Board Riser BoardsOnline Services Technical AssistanceGetting Help Automated Order-Status Service AutoTech ServiceTechnical Support Service Electronic Quote ServiceGetting Help Before You Call Page 100 Contacting DellMail la-techsupport@dell.com General Support Toll-free Mail la-techsupport@dell.com General Support101 Technical Support ServicesTechnical Support SalesGeneral Support Toll-free 102103 Mail la-techsupport@dell.com General Support 01-800-915-4755 104105 General Support calling from Guayaquil3355 Mail la-techsupport@dell.com General Support 800-6132 106107 108 109 110 Mail krsupport@dell.com 111112 113 Fax 21 424 01 114115 116 Technical Support OptiPlex, Latitude, Inspiron 117118 International Access Code Country Code City CodeMail delldirectsupport@dell.com Customer Care website Home and Small Business Fax 0870 907119 120 BTU British thermal unit Amperes AC Alternating currentCelsius GlossaryCPU Central processing unit. See processor DC Direct current 122Fahrenheit 123FBD Fully buffered Dimm Kilo Kb Kilobits 1024 bits GlossaryLVD Low voltage differential Meters MA Milliamperes 124125 TCP/IP Transmission Control Protocol/Internet Protocol 126Volts VAC Volts alternating current VDC Volts direct current 127128 Index Index130 Power supply, 42 system battery, 59 system board131 132
Related manuals
Manual 62 pages 21.19 Kb Manual 50 pages 30.93 Kb Manual 132 pages 63.73 Kb

SC1435 specifications

The Dell SC1435 is a versatile and reliable 1U rack server designed specifically for enterprise applications, virtualization, and cloud computing environments. Targeted towards businesses that require high performance and scalability, the SC1435 is an ideal choice for organizations looking to maximize their data center efficiency while minimizing their physical footprint.

One of the main features of the Dell SC1435 is its powerful processing capabilities. It supports up to two AMD Opteron processors, which can provide up to 12 cores per CPU, enabling robust multi-threaded performance. This allows businesses to run multiple applications simultaneously without compromising on speed or efficiency. The server also supports a range of AMD processors, offering flexibility to meet various workload requirements.

The SC1435 is equipped with significant memory capacity, supporting up to 128GB of DDR2 RAM. This high memory capacity allows for improved data management and processing, making it suitable for memory-intensive applications such as database management and virtualization. The server features eight DIMM slots, providing businesses the ability to scale memory as their workloads grow.

Storage is another critical aspect of the Dell SC1435, offering a range of options that cater to different needs. The server can be equipped with up to four hot-swappable 3.5-inch SATA or SAS drives, providing enterprises with the flexibility to balance performance needs and cost-efficiency. Additionally, it features support for RAID configurations, which enhances data protection and availability.

The SC1435 also integrates advanced management technologies, including Dell's OpenManage, which simplifies server management and allows for remote monitoring. This toolset provides administrators with the ability to easily configure, update, and monitor the server's health and performance metrics.

One of the standout characteristics of the SC1435 is its energy-efficient design. It incorporates power management features that help lower overall energy consumption, contributing to reduced operating costs and a smaller carbon footprint. The server’s compact size allows it to fit into standard 19-inch racks, making it an excellent option for space-constrained environments.

In summary, the Dell SC1435 is a robust 1U rack server that combines powerful processing capabilities, extensive memory support, flexibility in storage options, and advanced management features. Its energy-efficient design further enhances its appeal in modern data centers, making it a smart choice for organizations seeking to optimize their IT infrastructure.