Toshiba MV13P3 owner manual Call, Mute, Channel +

Page 21

CHANNEL + / –

Press and release CH + or . The channel automati- cally stops at the next channel set into memory.

For proper operation, before selecting channels, they should be set into the memory. See pages 23 and 24 “To memorize channels”.

CH 012

MUTE

Press MUTE to switch off the sound. The TV/VCR’s sound will be silenced and “MUTE” will briefly appear on the screen. The sound can be switched back on by press- ing this button again or one of the VOL + or .

MUTE

MUTE

CALL

VOL + / –

 

VOL

MENU

 

 

7

PROGRAM

CALL

0

RECTIMER

SPEED

 

REC

CH+

 

 

 

CLOSED

 

 

 

 

 

CAPTION

INPUT

 

 

1

 

 

 

 

 

SELECT

 

4

 

2

 

 

 

 

 

 

 

 

 

5

 

3

 

 

8

 

 

 

SKIP

 

6

 

 

 

 

TV

 

SEARCH

 

9

 

MONITOR

 

 

 

 

CHANNEL

RESETCOUNTER

 

 

RETURN

 

 

ZERO

 

SLEEP

 

 

 

RETURN

CANCEL

 

 

 

MUTE

 

 

 

 

 

 

 

 

 

POWER

EJECT

CALL

DIGITAL

 

 

 

 

TRACKING

 

CH

VOL+

 

 

 

 

 

INDEX

 

 

ENTER

 

+

TRACKING

 

 

MUTE

 

PLAY

 

 

 

REW

+

 

PAUSE

 

 

 

 

 

 

 

 

 

/STILL

 

 

STOP

FF

 

 

 

CH + / –

 

 

 

 

Press CALL. The clock, date, channel number, real time tape counter, tape speed and VCR operation will be

indicated.

VCR operation

Press CALL again to disappear the call display.

: Play

 

Current time

VCR operation

CALL

8:47AM THU

CH 012

 

Channel

 

 

 

Auto repeat

: Rewind

: Fast-forward

: Eject

: Recording

: Recording Pause

00:04:38 SP

Tape In

Tape speed

: Stop

: Zero return (Rewind)

Real time tape counter

: Zero return (Fast-forward)

NOTE: To listen through the headphone, insert a headphone (not supplied) with a 1/8” mini plug into PHONE jack on the front. The sound from the TV speaker is muted.

19

5L80301C P10-19

19

20/4/04, 16:26

Image 21
Contents MV13P3 TV/CABLE Mode SelectionRisk of Electric Shock Do not Open Accessories CleaningPower Source Grounding or Polarization Read InstructionsPower Lines POWER-CORD ProtectionReplacement Parts LightningSafety Check HeatNEC Section Features Table of Contents When YOU Experience the Above Conditions Safety PrecautionsMoisture Condensation Moisture will Condense on the Unit in the Following CasesPower Source To USE AC PowerWider Hole and Blade AC Outlet Front Rear Location of ControlsDescription of Controls FrontRemote Control Cursor Selects an item in the menuSpeed button Sets the tape speed for recording Battery Precautions Battery InstallationEffective Distance of the Remote Control FeetJack Antenna ConnectionsOhm matching transformer Antenna Jack Combiner UHF 300 ohm VHF 300 ohmFor Subscribers to Basic Cable TV Service For Subscribers to Scrambled Cable TV ServiceCable TV Connections Enter Starting SetupSetting the Language Auto Clock Setting Auto Clock SettingAuto Clock Adjustment To SET Auto Clock to OFFPress MENU. Press Bor a to select option Auto for automatic setting read EDS in the signalPress or to select Daylight Saving TIME, then press a Menu screen is clearedPress Bor Ato set Manual Clock SettingMonth, then press As in , then pressAdjust the volume level by Press PowerTV Operation Cable TV ChannelsMute CallChannel + MuteSleep Closed Caption Channel ReturnSleep Closed CaptionWhat is Closed CAPTIONING? Closed Captioning with a VCRTo View Closed Captions Cable TV chart To Memorize ChannelsTV/CABLE Selection Automatic Memory Tuning Then press aNumbers will remain red until auto memorizing is complete Channel selection To ADD/DELETE ChannelsTo Register Password Setting the V-CHIPEnter the same password Using Direct channelTo SET the V-CHIP To use the TV after the TV is protected EnterTo Change Password Press B or Ato select ON/OFF TIMER, then To SET the on TimerOn TIMER, then press a Option Press aTo SET the OFF Timer Press Bor Ato selectOption Press a Picture Control Adjustments CancelSelection Pressing Mode Picture Quality Adjusting the Picture PreferencePress B or a to select option PREFERENCE, then press a Press or to select the desired pictureLoading and Unloading a Video Cassette Automatic Power on and PlayLoading UnloadingTo Prevent Accidental Erasure To Record Again Tape Speed and Maximum PLAYBACK/RECORDING TimeSP Standard Play To Start Playback PlaybackStop To Stop PlaybackREW Digital Tracking ControlsTo Rewind or Forward the Tape Rapidly FORWARD/REVERSE Picture SearchStop Special PlaybackSkip Search PAUSE/STILLOver until the repeat mode is canceled To Watch a Tape RepeatedlyPress Bor Ato select on Recording and Viewing the Same TV Program Recording a TV ProgramTo Stop Recording To Stop Recording Temporarily Screen and the REC indicator will lightPress Direct channel selection 0-9orCH + Ple ChannelPress Direct channel ONE-TOUCH Timer Recording OTRPress or to select Timer REC SET Timer RecordingPosition, then press Enter Press the or to select the programSpeed as in step Timer REC indicator will lightPress Enter Steps 3 to 6 to set the second programCancel Other Functions for the Timer RecordingTo Cancel a Program If the Program ProgramUsing the Real Time Tape Counter To View the Counter DisplayDisplay the elapsed time Before playback or recording, press Using Zero Return000000 Press Zero ReturnTV Monitor To Monitor a TV ProgramIndex search Duplicating a Video Tape Connection to Another VCRConnection to Camcorder Reception Disturbances Check the following chart before requesting service Problem and Troubleshooting GuideSymptom Cause Possible Solution Power No powerRemote Control Symptom Cause Possible SolutionDepressed To turn on the closed caption RecordingVideo Head Cleaning Video Head CleaningVideo Head Clogging TelevisionLimited One 1 Year Warranty Limited Ninety 90 Day WarrantyLimited Two 2 Year Warranty of Picture Tube Rental UnitsToll Free How to Obtain Warranty ServiceContinental United States contact 04/04 U