FACTORY & ELECTRONIC ADJUSTMENT | VER1.0 |
From the Factory Adjustment Menu, choose the Color Temp. Adj option and the following OSD will appear.
DVI (RGB, COM) | 5400K (6500D, 9300K, 13800K) |
x=335 | y=343 |
GAIN | BIAS |
R G B | R G B |
X X X | X X X |
*Note: When adjusting the DVI and RGB color temperatures, please set the PDP input source so that it matches the color temperature source being adjusted (DVI color temp. to be adjusted with DVI source under DVI mode, RGB color temp. with RGB source under RGB mode, COM color temp. with Component source under Component1 mode).*
(8)Flatly place the Minolta Color Analyzer’s Photo Detector in contact with the center of the PDP screen.
1.2DVI Mode Color Temperature Adjustment Procedure:
(1)With the PDP’s DVI input connected to Chroma
(2)Press the Left/Right Button to switch between the Bias (R, G, B) and Gain (R, G, B) values. Use the Up/Down Buttons to change the Bias and Gain Values.
(3)5400K dark level center block adjustment procedure:
A.Press the Left/Right key on the remote control to select
B.Press the Left/Right key on the remote control to select
C.Press the Left/Right key on the remote control to select
D.Repeat steps A, B and C until the following final values are obtained:
x= 335±30
y= 343±30
Y = 0.4±0.1 FL
(4)5400K bright level center block adjustment procedure: (Please set the Chroma
A.Select
B.Select