GE 45608 manual Create Secondary Controller, To Change Advanced Configuration Settings, Value 1 =

Page 38

To Change Advanced Configuration Settings:

1.Enter Z-Wave setup mode and highlight ADV. CONFIG.

2.Press OK and screen will display PARAMETER 0

3.Use either ARROW key to scroll until the display reads the proper parameter number (1 - 255) as indicated in the Z-Wave device’s instructions

4.Press OK and the screen will read NUMBER OF BYTES

5.Use either ARROW key to scroll until the display reads the proper number of bytes (1, 2 or 4) as indicated in the Z-Wave device’s instructions

6.Press OK and the screen will display read CONFIGURATION

VALUE 1 = 0

7.Use either ARROW key to scroll until the display reads the proper value (0 - 255) as indicated in the Z-Wave device’s instructions

8.Press OK

9.Press the button on the device.

10.The screen will display SUCCESSFUL

Copying information to or from the remote control:

Create Secondary, Controller Swap and Receive are all methods used in the process of replication.

Create Secondary Controller

A Primary controller must be used to add or delete devices from your network; however, secondary controllers can be created to enhance convenience (remotes in multiple locations like the kitchen, master bedroom and family room) and functionality (control of more than 18 individual lights, 18 groups or 18 scenes).

There are two ways to create a secondary controller. The first way is to copy all network and device information while the second is to copy just the network information. If the two remotes are identical (two of the GE 45608s for example), the first method creates an exact duplicate of all Z-Wave information including groups, scenes, labels, etc. The second method copies only the network and does not duplicate the groups, scenes, labels, etc.

 

 

 

 

Transfer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Create

 

 

Controller

 

Secondary

 

 

Swap

 

 

 

 

 

 

 

 

Receive

38

Image 38
Contents Home Theater Remote Table of Contents Key Features include IntroductionAudio/Video Key Chart Channel UP & Down Changes channel on active A/V devicePage Automatic Time-Out SetupBatteries Initial Setup Audio/Video Devices Adding a Device by Entering Its CodeAdding a Device by Searching for Its Code Viewing a Programmed Device Code Changing a Device CodeDeleting a Device Replacing a Device To Access the Advanced Functions MenuAdvanced Functions Audio/Video Devices Set Volume Control Volume Lock Locking Volume Control to Other DevicesThen Press OK Volume LockRemoved from Volume Lock SET to ReceiverKey Mover Key Macros Memory Full Learning Macro Deleted Choose Another or OK to ExitDeleting All Learned Keys Delete ALLFrom Advanced FUNCTIONS, scroll to LCD TIMER. Press OK Setting the LCD Display’s ContrastAdjusting the LCD Timer Deleting a Single Learned KeyResetting the Remote Resetting All Audio/Video FeaturesWave Overview Risk of Fire Risk of Electrical Shock Risk of BurnsWave Terminology Wireless Range Things to consider regarding RF rangeImportant Notes on New Remotes Wave Key Chart Mode KeysPage Adding a Device Node / Light to the Network Wave SetupDevices / Lights / Nodes Controlling an Individual Device Node / Light Add a device without assigning it to a specific number keyAdd a device and assign it to a specific number key Deleting a Device Node / Light From Your Network Setting a Light’s Brightness LevelTurning a Light On or Off To control a Group GroupsCreate a Group or Add a Device to a Group Deleting a Group ScenesRemoving a Device Node / Light From a Group Adding a Device Node / Light to a Scene To control a sceneRemoving a Device Node / Light From a Scene Scene SetupLabels Deleting a SceneAll-On and All-Off Control Turn all devices on or offOFF only EventsAdding or Excluding a Device To / From All Control Adding an EventPage Enabling or Disabling All Events ThermostatsEnabling or Disabling an Individual Event Deleting an EventControlling a Thermostat Advanced ConfigurationAdding a Thermostat Deleting a ThermostatCreate Secondary Controller To Change Advanced Configuration SettingsCopying information to or from the remote control Value 1 =To send only network information to a secondary remote Network onlyController Swap Transfer Primary Controller SwapReceiving Network and Device Information To reset your network Resetting Your NetworkRecovering Network Information To recover network informationFCC Notice Network UpdateInteroperability with Z-WaveDevices Warranty Setup Codes for Compatible Brands of Audio/Video Devices For Audio ReceiverFor Audio Accessory Accesorios de Audio For Audio CD Reproductores de CDsFor Audio Accessory, For Satellite Set Top Box Receptores de SatéliteFor Video DVD For Satellite Set Top Box,For Video DVD, cont. Reproductores DVD, Mitsubishi . . . . . . .0060, 0000 For Video Accessory Accesorios de Video For Television TelevisoresFor Television, cont. Televisores, Electroband Electrograph Electrohome . . . . .0154, 0000Orion . . . . . .0017, 0236, 0463 0145, 0171

45608 specifications

The GE 45608, a locomotive model manufactured by General Electric, has made significant contributions to the freight rail industry since its inception. Known for its powerful performance and advanced technology, the GE 45608 is designed to meet the demanding needs of freight transport while ensuring reliability and efficiency.

One of the standout features of the GE 45608 is its robust engine. Utilizing a 12-cylinder V-type diesel engine, it produces substantial horsepower, enabling it to haul heavy loads over challenging terrains. The locomotive's propulsion system is complemented by advanced traction control technology, which enhances its pulling power and stability, particularly on inclines. This feature is vital for operations in regions with varying topography.

The GE 45608 is equipped with an advanced control system that provides real-time diagnostics and performance monitoring. This technology allows operators to track the locomotive's health and efficiency, ensuring it runs optimally throughout its service life. The user-friendly interface enables quick access to critical data, aiding in troubleshooting and maintenance planning.

Safety is another crucial aspect of the GE 45608's design. The locomotive includes multiple safety features such as dynamic braking systems, which provide effective stopping power while reducing wear on the wheels. Additionally, it incorporates enhancements like GPS-based location tracking and the latest in collision avoidance technology, ensuring safe operation in freight yards and on main lines.

In terms of fuel efficiency, the GE 45608 stands out among its peers. Its engine is designed to optimize fuel consumption while delivering the required power, making it a cost-effective choice for rail operators. This efficiency not only reduces operational costs but also lessens the environmental impact by lowering emissions.

The locomotive's build quality reflects GE's commitment to durability. Constructed with high-grade materials, including corrosion-resistant components, the GE 45608 is engineered for longevity, making it a valuable asset for any freight operation.

In summary, the GE 45608 is a locomotive that combines power, advanced technology, and rugged durability. Its significant features, including a strong engine, sophisticated control systems, safety enhancements, and efficiency measures, make it a reliable choice for the freight rail industry. As rail transport continues to evolve, the GE 45608 exemplifies the innovations that drive operational success.