When PON-1 goes High, Q9A21 turns Off, allowing Q9A20 to turn On. With Q9A20 conducting, the 12V supply is generated from the 12VS supply. The 12V supply enables IC9A22 and the 5V-1 supply is gener- ated.
Time Shift Supply Power Distribution
Figure 3-8illustrates the Power Distribution for the Time Shift supplies. The 5V-1 supply is used by the MLink, 3DYC and Signal Select circuitry. It is also the source for the 3.3V-2 supply, which is directed to the Conver-