EverFocus EDR-1640, EDR-920 manual Camera Menu, Install / Covert

Page 32

3.2 CAMERA MENU

CAMERA

CAMERA1

TITLE

 

 

CH1

 

CAMERA2

PTZ ID

 

 

01

 

CAMERA3

INSTALL/COVERT

ON/OFF

CAMERA4

SEQ (MAIN/CALL)

03/03 SECS

CAMERA5

REC QUALITY

 

HIGH

CAMERA6

REC SPEED ON TIME ZONE

CAMERA7

TP

NORMAL

EVENT

SET

CAMERA8

1

5

IPS

25

IPS

OFF

CAMERA9

2

5

IPS

25

IPS

OFF

 

SUMMARY

3

5

IPS

25

IPS

OFF

4

5

IPS

25

IPS

OFF

 

5

5

IPS

25

IPS

OFF

 

6

5

IPS

25

IPS

OFF

 

7

5

IPS

25

IPS

OFF

 

8

5

IPS

25

IPS

OFF

 

N

5

IPS

25 IPS

OFF

Menu display for EDR-920, EDR1640 identical, but with 16 cameras.

The most important recording operation settings are defined in the CAMERA menu. Before changing the settings in this menu, recording has to be stopped.

Each camera is set individually:

(1)NAME: Enter the video channel description with max. 12 characters each. Available characters are (select with JOG):

0,1,2,3,4,5,6,7,8,9,

A,B,C,D,E,F,G,H,I,J,K,L,M,N,O,P,Q,R,S,T,U,V,W,X,Y,Z, ( ) . , + - / and space

(2)PTZ ID: Enter the RS-485 receiver address of a speed dome or telemetry receiver camera connected to this video channel.

(3)INSTALL / COVERT:

INSTALL (first position) All connected cameras have to be set to ON, all not connected cameras are set to OFF.

ATTENTION: The manual setting is compulsory, autodetection for connected cameras is not available!

COVERT (second position): A camera programmed COVERT “ON” will not be displayed, but recorded at defined parameters.

(4)SEQ(MAIN/CALL): Camera dwell time in sequence operation (automatic switching) for main (first position) and call (second position) monitor

ATTENTION: Some Pelco-D / -P protocol domes and receivers require an address offset of -1, i.e. the address assigned to the dome / receiver in the DVR camera menu must be 1 below the address set in the dome / receiver itself!

31

Image 32
Contents EDR-920 Safety warnings Safety warningsTable of Contents Recording PlaybackDelivery Scope FeaturesIntroduction Technical Data Video inputTitle generator Front Panel Operating Elements KeysJog / Shuttle Page Connections Audio output Audio outputVideo inputs EDR920 EDR1640Page Global types of event Screen DisplaysChannel-related types of event XX% Playback date Playback status Playback positionPause HDD fan message Video connection installation, DVR cascading Delivery scopeDVR cascading Audio connection installation Audio Recording FunctionalityRS-485 keyboard installation General RS-485 bus installationPage 2 RS-485 plug connection assignment EKB-500 connection with network patch cableEKB-500 connection to several DVRs Speed dome installation Alarm input / output installation DescriptionsPS/2 mouse installation Installation EDA800s harddisk expansion unitNetwork connection Direct PC connection through crossover network cableNetwork connection through patch cable Network system requirementsStart-up Power connectionHarddisks Setup Menu Date Time / Date MenuTime Central Europe daylight saving time adjustment Time Zone Time SynchronisationTime Server Install / Covert Camera MenuSuperior High Standard Basic LOW Lower REC Speed on Time ZoneSummary Copy functionRecording Menu Record AudioTime Stamp Time Stamp POSResolution Record ModeAlarm Menu AlarmAlarm Type Active CameraSummary Alarm Output Motion DetectionMotion SensitivityPage Area Setup Video Loss Menu VlossNetwork Menu NetworkAlarm Network alarm Email Email alarm Password Timer Menu DAYCorrect SET activationHDD harddisk Menu 10 RS232/RS485 Menu Network Alarm FAN FailureHDD Temp Stop RecordNo HDD 5EMAILHDD Full SAVE/LOAD Configuration System MenuSystem Password User rights, version Recording RecordingTimer scheduled recording Event recordingFast forward / reverse PlaybackPlayback Without Search Function Slow forward playback Single image playbackTime / Date Search Playback SearchNavigation Vloss AlarmEvent Search Video Export USB socketPage Call / Matrix Monitor Setup BRIGHTNESS, CONTRAST, Colour Display SettingsImage Position Adjustment on Monitor Screen Display EDA 966 Infrared Remote Control optional PC System Requirements Network AccessAccess VIA Internet Explorer Reverse Playback PlaybackEvent list search mode Playback SearchTime / Date Search Preset PTZ ControlAppendix a EDR Viewer Software Appendix a EDR Viewer SoftwareEDR Viewer Installation Interface Specification DVR HostRemote control protocol Sample control code packetsFormat of message packet is as follows Length Byte16383 1111111 All DVR Connect to RS485/RS232 Opcode Byte & Data bytes OPcode Remote keys OPcode=0x4BMatrix command OPcode=0x4D Checksum ByteAppendix D Recording times Head Office USA Office China Office Japan Office