3.10 RS232/RS485 MENU
CONTROL SETUP MENU
RS232 |
|
|
BAUD RATE | 9600 BPS |
|
STOP BIT | 1 |
|
PARITY | NONE | |
DATA BIT | 8 |
|
RS485 |
|
|
BAUD RATE | 9600 BPS | |
STOP BIT | 1 |
|
PARITY | NONE | |
DATA BIT | 8 |
|
RS232/RS485 ID | 1 |
|
PTZ PROTOCOL | EVERFOCUS |
Define the settings for DVR remote control through serial interface in the RS232/RS485 menu. Pin assignment and remote control protocol are described in appendix B and C.
(1)RS232 BAUD RATE:
Default setting: 9600 baud
(2)RS232 STOP BIT: Number of stop bits: 1 or 2
(3)RS232 PARITY: Parity mode: NONE / EVEN / ODD
(4)RS232 DATA BIT: Number of data bits: 8 or 7
(5)RS485 BAUD RATE:
Default setting: 9600 baud
(6)RS485 STOP BIT: Number of stop bits: 1 or 2
(7)RS485 PARITY: Parity mode: NONE / EVEN / ODD
(8)RS485 DATA BIT: Number of data bits: 8 or 7
(9)RS232/RS485 ID: RS232/RS485 address. Addressable range: 1~255.
This address complies with the device number for remote control through keyboards EKB 500, KS KBK and KS KBJ (DEVICE No.).
(10)
EVERFOCUS1 (EPTZ1800 Dome), EVERFOCUS2 (EPTZ1000/3000 Dome),
ED2200/2250 (complies with Samsung protocol
NOTE: Standard setting for EKB500 keyboard connection: